Double-conversion UPS efficiency under varying mains conditions

Efficiency is a fundamental UPS performance criterion. Remarkably, UPS efficiency in field applications may deviate from controlled laboratory conditions. This paper focuses on the impact of mains supply on double-conversion UPS efficiency. As the mains supply mostly affects the rectifier section, t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Giuntini, Lorenzo, Mannuccini, Andrea
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 9
container_issue
container_start_page 1
container_title
container_volume
creator Giuntini, Lorenzo
Mannuccini, Andrea
description Efficiency is a fundamental UPS performance criterion. Remarkably, UPS efficiency in field applications may deviate from controlled laboratory conditions. This paper focuses on the impact of mains supply on double-conversion UPS efficiency. As the mains supply mostly affects the rectifier section, the results also provide a reference on the impact of mains supply on rectifier efficiency.
doi_str_mv 10.1109/EPE.2013.6631768
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6631768</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6631768</ieee_id><sourcerecordid>6631768</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-d80215439af977197cb0ae7fae2034ff22bde7c2397590a49ca17d3e5da944783</originalsourceid><addsrcrecordid>eNotj01LAzEUReNCqNTZF9zkD8z48jGTeSuROlqhYMG6LpnkRSJtRiZtof_eAbu6m8M99zK2EFAJAfjYbbpKglBV0yhhmvaGFWhaoQ0iCNE0M1bk_AMAwhhRa33Hnl6GU7-n0g3pTGOOQ-Jfm09OIUQXKbkLPyVPIz_b8RLTNz_YmDKfaB-PE5zv2W2w-0zFNeds-9ptl6ty_fH2vnxelxHhWPoW5ORTaANOZjSuB0smWJKgdAhS9p6MkwpNjWA1OiuMV1R7i1qbVs3Zw39tJKLd7xgP057d9aX6A9KYR6g</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Double-conversion UPS efficiency under varying mains conditions</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Giuntini, Lorenzo ; Mannuccini, Andrea</creator><creatorcontrib>Giuntini, Lorenzo ; Mannuccini, Andrea</creatorcontrib><description>Efficiency is a fundamental UPS performance criterion. Remarkably, UPS efficiency in field applications may deviate from controlled laboratory conditions. This paper focuses on the impact of mains supply on double-conversion UPS efficiency. As the mains supply mostly affects the rectifier section, the results also provide a reference on the impact of mains supply on rectifier efficiency.</description><identifier>EISBN: 9781479901166</identifier><identifier>EISBN: 1479901164</identifier><identifier>DOI: 10.1109/EPE.2013.6631768</identifier><language>eng</language><publisher>IEEE</publisher><subject>Conduction losses ; Efficiency ; Power quality ; Reactive power ; Rectifiers ; Switches ; Switching loss ; Switching losses ; Topology ; Uninterruptible Power Supply (UPS) ; Uninterruptible power systems ; Voltage measurement</subject><ispartof>2013 15th European Conference on Power Electronics and Applications (EPE), 2013, p.1-9</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6631768$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6631768$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Giuntini, Lorenzo</creatorcontrib><creatorcontrib>Mannuccini, Andrea</creatorcontrib><title>Double-conversion UPS efficiency under varying mains conditions</title><title>2013 15th European Conference on Power Electronics and Applications (EPE)</title><addtitle>EPE</addtitle><description>Efficiency is a fundamental UPS performance criterion. Remarkably, UPS efficiency in field applications may deviate from controlled laboratory conditions. This paper focuses on the impact of mains supply on double-conversion UPS efficiency. As the mains supply mostly affects the rectifier section, the results also provide a reference on the impact of mains supply on rectifier efficiency.</description><subject>Conduction losses</subject><subject>Efficiency</subject><subject>Power quality</subject><subject>Reactive power</subject><subject>Rectifiers</subject><subject>Switches</subject><subject>Switching loss</subject><subject>Switching losses</subject><subject>Topology</subject><subject>Uninterruptible Power Supply (UPS)</subject><subject>Uninterruptible power systems</subject><subject>Voltage measurement</subject><isbn>9781479901166</isbn><isbn>1479901164</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2013</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotj01LAzEUReNCqNTZF9zkD8z48jGTeSuROlqhYMG6LpnkRSJtRiZtof_eAbu6m8M99zK2EFAJAfjYbbpKglBV0yhhmvaGFWhaoQ0iCNE0M1bk_AMAwhhRa33Hnl6GU7-n0g3pTGOOQ-Jfm09OIUQXKbkLPyVPIz_b8RLTNz_YmDKfaB-PE5zv2W2w-0zFNeds-9ptl6ty_fH2vnxelxHhWPoW5ORTaANOZjSuB0smWJKgdAhS9p6MkwpNjWA1OiuMV1R7i1qbVs3Zw39tJKLd7xgP057d9aX6A9KYR6g</recordid><startdate>201309</startdate><enddate>201309</enddate><creator>Giuntini, Lorenzo</creator><creator>Mannuccini, Andrea</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201309</creationdate><title>Double-conversion UPS efficiency under varying mains conditions</title><author>Giuntini, Lorenzo ; Mannuccini, Andrea</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-d80215439af977197cb0ae7fae2034ff22bde7c2397590a49ca17d3e5da944783</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Conduction losses</topic><topic>Efficiency</topic><topic>Power quality</topic><topic>Reactive power</topic><topic>Rectifiers</topic><topic>Switches</topic><topic>Switching loss</topic><topic>Switching losses</topic><topic>Topology</topic><topic>Uninterruptible Power Supply (UPS)</topic><topic>Uninterruptible power systems</topic><topic>Voltage measurement</topic><toplevel>online_resources</toplevel><creatorcontrib>Giuntini, Lorenzo</creatorcontrib><creatorcontrib>Mannuccini, Andrea</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Giuntini, Lorenzo</au><au>Mannuccini, Andrea</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Double-conversion UPS efficiency under varying mains conditions</atitle><btitle>2013 15th European Conference on Power Electronics and Applications (EPE)</btitle><stitle>EPE</stitle><date>2013-09</date><risdate>2013</risdate><spage>1</spage><epage>9</epage><pages>1-9</pages><eisbn>9781479901166</eisbn><eisbn>1479901164</eisbn><abstract>Efficiency is a fundamental UPS performance criterion. Remarkably, UPS efficiency in field applications may deviate from controlled laboratory conditions. This paper focuses on the impact of mains supply on double-conversion UPS efficiency. As the mains supply mostly affects the rectifier section, the results also provide a reference on the impact of mains supply on rectifier efficiency.</abstract><pub>IEEE</pub><doi>10.1109/EPE.2013.6631768</doi><tpages>9</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier EISBN: 9781479901166
ispartof 2013 15th European Conference on Power Electronics and Applications (EPE), 2013, p.1-9
issn
language eng
recordid cdi_ieee_primary_6631768
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Conduction losses
Efficiency
Power quality
Reactive power
Rectifiers
Switches
Switching loss
Switching losses
Topology
Uninterruptible Power Supply (UPS)
Uninterruptible power systems
Voltage measurement
title Double-conversion UPS efficiency under varying mains conditions
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T03%3A17%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Double-conversion%20UPS%20efficiency%20under%20varying%20mains%20conditions&rft.btitle=2013%2015th%20European%20Conference%20on%20Power%20Electronics%20and%20Applications%20(EPE)&rft.au=Giuntini,%20Lorenzo&rft.date=2013-09&rft.spage=1&rft.epage=9&rft.pages=1-9&rft_id=info:doi/10.1109/EPE.2013.6631768&rft_dat=%3Cieee_6IE%3E6631768%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781479901166&rft.eisbn_list=1479901164&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6631768&rfr_iscdi=true