Health diagnostics of water-cooled power generator stator windings using a Directional Mahalanobis Distance (DMD)

A power generator, one of the most critical components in power plant, could experience unexpected series system failures, resulting in substantial maintenance and societal cost. This paper proposes a new health diagnostics method for water-cooled power generator windings against moisture absorption...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Kyung Min Park, Youn, Byeng D., Joung Taek Yoon, Chao Hu, Hee Soo Kim, Yong Chae Bae
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 8
container_issue
container_start_page 1
container_title
container_volume
creator Kyung Min Park
Youn, Byeng D.
Joung Taek Yoon
Chao Hu
Hee Soo Kim
Yong Chae Bae
description A power generator, one of the most critical components in power plant, could experience unexpected series system failures, resulting in substantial maintenance and societal cost. This paper proposes a new health diagnostics method for water-cooled power generator windings against moisture absorption. The main idea of the proposed diagnostics method is a Directional Mahalanobis Distance (DMD) based on the correlation matrix of health data. In this study capacitance data measured from a winding insulator is referred to as health data. It is an indirect measure of moisture absorption in power generator windings by water leakage. Data from ten generators, of which each has 42 windings, are used for demonstration of the proposed health diagnostics method for power generator windings.
doi_str_mv 10.1109/ICPHM.2013.6621439
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6621439</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6621439</ieee_id><sourcerecordid>6621439</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-38942a13680438538875a6ab07852250b03545b39574baac26ab7aa620e1d2443</originalsourceid><addsrcrecordid>eNotkD1PwzAURc2ABJT-AVg8wpDibycjSimt1AqG7tVL8poaBbvYRhX_ngg6HelenTtcQu44m3HOqqdV_b7czATjcmaM4EpWF-SGK2OltkLYKzJN6YMxxq0xWopr8rVEGPKBdg56H1J2baJhT0-QMRZtCAN29BhOGGmPHiPkEGnKfzg53znfJ_qdRlCgcxexzS54GOgGDjCAD41LYz4avkX6MN_MH2_J5R6GhNMzJ2S7eNnWy2L99rqqn9eFq1guZFkpAVyakilZalmWVoOBhtlSC6FZw6RWupGVtqoBaMXYWQAjGPJOKCUn5P5_1iHi7hjdJ8Sf3fkU-Qt2hVgB</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Health diagnostics of water-cooled power generator stator windings using a Directional Mahalanobis Distance (DMD)</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Kyung Min Park ; Youn, Byeng D. ; Joung Taek Yoon ; Chao Hu ; Hee Soo Kim ; Yong Chae Bae</creator><creatorcontrib>Kyung Min Park ; Youn, Byeng D. ; Joung Taek Yoon ; Chao Hu ; Hee Soo Kim ; Yong Chae Bae</creatorcontrib><description>A power generator, one of the most critical components in power plant, could experience unexpected series system failures, resulting in substantial maintenance and societal cost. This paper proposes a new health diagnostics method for water-cooled power generator windings against moisture absorption. The main idea of the proposed diagnostics method is a Directional Mahalanobis Distance (DMD) based on the correlation matrix of health data. In this study capacitance data measured from a winding insulator is referred to as health data. It is an indirect measure of moisture absorption in power generator windings by water leakage. Data from ten generators, of which each has 42 windings, are used for demonstration of the proposed health diagnostics method for power generator windings.</description><identifier>EISBN: 1467357227</identifier><identifier>EISBN: 9781467357234</identifier><identifier>EISBN: 1467357235</identifier><identifier>EISBN: 9781467357227</identifier><identifier>DOI: 10.1109/ICPHM.2013.6621439</identifier><language>eng</language><publisher>IEEE</publisher><subject>Absorption ; Correlation ; Directional Mahalanobis Distance ; Equations ; Health Diagnostics ; Moisture Absorption ; Power Generator Stator Winding ; Statistical Correlation ; Windings</subject><ispartof>2013 IEEE Conference on Prognostics and Health Management (PHM), 2013, p.1-8</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6621439$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6621439$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Kyung Min Park</creatorcontrib><creatorcontrib>Youn, Byeng D.</creatorcontrib><creatorcontrib>Joung Taek Yoon</creatorcontrib><creatorcontrib>Chao Hu</creatorcontrib><creatorcontrib>Hee Soo Kim</creatorcontrib><creatorcontrib>Yong Chae Bae</creatorcontrib><title>Health diagnostics of water-cooled power generator stator windings using a Directional Mahalanobis Distance (DMD)</title><title>2013 IEEE Conference on Prognostics and Health Management (PHM)</title><addtitle>ICPHM</addtitle><description>A power generator, one of the most critical components in power plant, could experience unexpected series system failures, resulting in substantial maintenance and societal cost. This paper proposes a new health diagnostics method for water-cooled power generator windings against moisture absorption. The main idea of the proposed diagnostics method is a Directional Mahalanobis Distance (DMD) based on the correlation matrix of health data. In this study capacitance data measured from a winding insulator is referred to as health data. It is an indirect measure of moisture absorption in power generator windings by water leakage. Data from ten generators, of which each has 42 windings, are used for demonstration of the proposed health diagnostics method for power generator windings.</description><subject>Absorption</subject><subject>Correlation</subject><subject>Directional Mahalanobis Distance</subject><subject>Equations</subject><subject>Health Diagnostics</subject><subject>Moisture Absorption</subject><subject>Power Generator Stator Winding</subject><subject>Statistical Correlation</subject><subject>Windings</subject><isbn>1467357227</isbn><isbn>9781467357234</isbn><isbn>1467357235</isbn><isbn>9781467357227</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2013</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotkD1PwzAURc2ABJT-AVg8wpDibycjSimt1AqG7tVL8poaBbvYRhX_ngg6HelenTtcQu44m3HOqqdV_b7czATjcmaM4EpWF-SGK2OltkLYKzJN6YMxxq0xWopr8rVEGPKBdg56H1J2baJhT0-QMRZtCAN29BhOGGmPHiPkEGnKfzg53znfJ_qdRlCgcxexzS54GOgGDjCAD41LYz4avkX6MN_MH2_J5R6GhNMzJ2S7eNnWy2L99rqqn9eFq1guZFkpAVyakilZalmWVoOBhtlSC6FZw6RWupGVtqoBaMXYWQAjGPJOKCUn5P5_1iHi7hjdJ8Sf3fkU-Qt2hVgB</recordid><startdate>201306</startdate><enddate>201306</enddate><creator>Kyung Min Park</creator><creator>Youn, Byeng D.</creator><creator>Joung Taek Yoon</creator><creator>Chao Hu</creator><creator>Hee Soo Kim</creator><creator>Yong Chae Bae</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201306</creationdate><title>Health diagnostics of water-cooled power generator stator windings using a Directional Mahalanobis Distance (DMD)</title><author>Kyung Min Park ; Youn, Byeng D. ; Joung Taek Yoon ; Chao Hu ; Hee Soo Kim ; Yong Chae Bae</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-38942a13680438538875a6ab07852250b03545b39574baac26ab7aa620e1d2443</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Absorption</topic><topic>Correlation</topic><topic>Directional Mahalanobis Distance</topic><topic>Equations</topic><topic>Health Diagnostics</topic><topic>Moisture Absorption</topic><topic>Power Generator Stator Winding</topic><topic>Statistical Correlation</topic><topic>Windings</topic><toplevel>online_resources</toplevel><creatorcontrib>Kyung Min Park</creatorcontrib><creatorcontrib>Youn, Byeng D.</creatorcontrib><creatorcontrib>Joung Taek Yoon</creatorcontrib><creatorcontrib>Chao Hu</creatorcontrib><creatorcontrib>Hee Soo Kim</creatorcontrib><creatorcontrib>Yong Chae Bae</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Kyung Min Park</au><au>Youn, Byeng D.</au><au>Joung Taek Yoon</au><au>Chao Hu</au><au>Hee Soo Kim</au><au>Yong Chae Bae</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Health diagnostics of water-cooled power generator stator windings using a Directional Mahalanobis Distance (DMD)</atitle><btitle>2013 IEEE Conference on Prognostics and Health Management (PHM)</btitle><stitle>ICPHM</stitle><date>2013-06</date><risdate>2013</risdate><spage>1</spage><epage>8</epage><pages>1-8</pages><eisbn>1467357227</eisbn><eisbn>9781467357234</eisbn><eisbn>1467357235</eisbn><eisbn>9781467357227</eisbn><abstract>A power generator, one of the most critical components in power plant, could experience unexpected series system failures, resulting in substantial maintenance and societal cost. This paper proposes a new health diagnostics method for water-cooled power generator windings against moisture absorption. The main idea of the proposed diagnostics method is a Directional Mahalanobis Distance (DMD) based on the correlation matrix of health data. In this study capacitance data measured from a winding insulator is referred to as health data. It is an indirect measure of moisture absorption in power generator windings by water leakage. Data from ten generators, of which each has 42 windings, are used for demonstration of the proposed health diagnostics method for power generator windings.</abstract><pub>IEEE</pub><doi>10.1109/ICPHM.2013.6621439</doi><tpages>8</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier EISBN: 1467357227
ispartof 2013 IEEE Conference on Prognostics and Health Management (PHM), 2013, p.1-8
issn
language eng
recordid cdi_ieee_primary_6621439
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Absorption
Correlation
Directional Mahalanobis Distance
Equations
Health Diagnostics
Moisture Absorption
Power Generator Stator Winding
Statistical Correlation
Windings
title Health diagnostics of water-cooled power generator stator windings using a Directional Mahalanobis Distance (DMD)
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-21T13%3A39%3A04IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Health%20diagnostics%20of%20water-cooled%20power%20generator%20stator%20windings%20using%20a%20Directional%20Mahalanobis%20Distance%20(DMD)&rft.btitle=2013%20IEEE%20Conference%20on%20Prognostics%20and%20Health%20Management%20(PHM)&rft.au=Kyung%20Min%20Park&rft.date=2013-06&rft.spage=1&rft.epage=8&rft.pages=1-8&rft_id=info:doi/10.1109/ICPHM.2013.6621439&rft_dat=%3Cieee_6IE%3E6621439%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1467357227&rft.eisbn_list=9781467357234&rft.eisbn_list=1467357235&rft.eisbn_list=9781467357227&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6621439&rfr_iscdi=true