Experimental study on the impact of harmonics on transformer
Impacts of harmonics on step-down transformer are presented in this paper. Transformer failure had been reported due to harmonic current causing excessive winding temperature rise. Excessive temperature rise of transformer is due to harmonic effect result in higher power loss than normal operating m...
Gespeichert in:
Hauptverfasser: | , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 690 |
---|---|
container_issue | |
container_start_page | 686 |
container_title | |
container_volume | |
creator | Soh, T. L. G. Said, D. M. Ahmad, N. Nor, K. M. Salim, F. |
description | Impacts of harmonics on step-down transformer are presented in this paper. Transformer failure had been reported due to harmonic current causing excessive winding temperature rise. Excessive temperature rise of transformer is due to harmonic effect result in higher power loss than normal operating mode. An experimental setup is proposed which allow for observation of harmonics. This research focuses on the transformer losses under nonlinear load with different power consumption. Moreover, the trends of Total Harmonic Distortion (THD) with nonlinear load are reported. |
doi_str_mv | 10.1109/PEOCO.2013.6564634 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6564634</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6564634</ieee_id><sourcerecordid>6564634</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-b7565287a555c13d90e3c213104a4d9d406270344d035f08067995074fab6ee23</originalsourceid><addsrcrecordid>eNo1j9tKw0AYhFdEUGteQG_2BRL_Pe-CNxJiFQrxor0u2-QPXWkO7Eawb2_VejUMwwzfEHLPoGAM3ON7VZd1wYGJQisttZAXJHPGMqmNUGCkuSS3_4a7a5Kl9AEAp7K2Vt2Qp-prwhh6HGZ_oGn-bI90HOi8Rxr6yTczHTu697Efh9Ck3yj6IXVj7DHekavOHxJmZ12QzUu1Ll_zVb18K59XeWBGzfnOKK24NV4p1TDROkDRcCYYSC9b10rQ3ICQsgWhOrCgjXM_8J3faUQuFuThbzcg4nY64fp43J4Pi2-M3kgG</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Experimental study on the impact of harmonics on transformer</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Soh, T. L. G. ; Said, D. M. ; Ahmad, N. ; Nor, K. M. ; Salim, F.</creator><creatorcontrib>Soh, T. L. G. ; Said, D. M. ; Ahmad, N. ; Nor, K. M. ; Salim, F.</creatorcontrib><description>Impacts of harmonics on step-down transformer are presented in this paper. Transformer failure had been reported due to harmonic current causing excessive winding temperature rise. Excessive temperature rise of transformer is due to harmonic effect result in higher power loss than normal operating mode. An experimental setup is proposed which allow for observation of harmonics. This research focuses on the transformer losses under nonlinear load with different power consumption. Moreover, the trends of Total Harmonic Distortion (THD) with nonlinear load are reported.</description><identifier>ISBN: 1467350729</identifier><identifier>ISBN: 9781467350723</identifier><identifier>EISBN: 9781467350747</identifier><identifier>EISBN: 1467350745</identifier><identifier>EISBN: 1467350737</identifier><identifier>EISBN: 9781467350730</identifier><identifier>DOI: 10.1109/PEOCO.2013.6564634</identifier><language>eng</language><publisher>IEEE</publisher><subject>efficiency ; harmonic ; Harmonic analysis ; Light emitting diodes ; nonlinear load ; Phase transformers ; Power system harmonics ; transformer losses ; Universal Serial Bus ; Voltage control ; Windings</subject><ispartof>2013 IEEE 7th International Power Engineering and Optimization Conference (PEOCO), 2013, p.686-690</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6564634$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2056,27924,54919</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6564634$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Soh, T. L. G.</creatorcontrib><creatorcontrib>Said, D. M.</creatorcontrib><creatorcontrib>Ahmad, N.</creatorcontrib><creatorcontrib>Nor, K. M.</creatorcontrib><creatorcontrib>Salim, F.</creatorcontrib><title>Experimental study on the impact of harmonics on transformer</title><title>2013 IEEE 7th International Power Engineering and Optimization Conference (PEOCO)</title><addtitle>PEOCO</addtitle><description>Impacts of harmonics on step-down transformer are presented in this paper. Transformer failure had been reported due to harmonic current causing excessive winding temperature rise. Excessive temperature rise of transformer is due to harmonic effect result in higher power loss than normal operating mode. An experimental setup is proposed which allow for observation of harmonics. This research focuses on the transformer losses under nonlinear load with different power consumption. Moreover, the trends of Total Harmonic Distortion (THD) with nonlinear load are reported.</description><subject>efficiency</subject><subject>harmonic</subject><subject>Harmonic analysis</subject><subject>Light emitting diodes</subject><subject>nonlinear load</subject><subject>Phase transformers</subject><subject>Power system harmonics</subject><subject>transformer losses</subject><subject>Universal Serial Bus</subject><subject>Voltage control</subject><subject>Windings</subject><isbn>1467350729</isbn><isbn>9781467350723</isbn><isbn>9781467350747</isbn><isbn>1467350745</isbn><isbn>1467350737</isbn><isbn>9781467350730</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2013</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo1j9tKw0AYhFdEUGteQG_2BRL_Pe-CNxJiFQrxor0u2-QPXWkO7Eawb2_VejUMwwzfEHLPoGAM3ON7VZd1wYGJQisttZAXJHPGMqmNUGCkuSS3_4a7a5Kl9AEAp7K2Vt2Qp-prwhh6HGZ_oGn-bI90HOi8Rxr6yTczHTu697Efh9Ck3yj6IXVj7DHekavOHxJmZ12QzUu1Ll_zVb18K59XeWBGzfnOKK24NV4p1TDROkDRcCYYSC9b10rQ3ICQsgWhOrCgjXM_8J3faUQuFuThbzcg4nY64fp43J4Pi2-M3kgG</recordid><startdate>201306</startdate><enddate>201306</enddate><creator>Soh, T. L. G.</creator><creator>Said, D. M.</creator><creator>Ahmad, N.</creator><creator>Nor, K. M.</creator><creator>Salim, F.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201306</creationdate><title>Experimental study on the impact of harmonics on transformer</title><author>Soh, T. L. G. ; Said, D. M. ; Ahmad, N. ; Nor, K. M. ; Salim, F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-b7565287a555c13d90e3c213104a4d9d406270344d035f08067995074fab6ee23</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2013</creationdate><topic>efficiency</topic><topic>harmonic</topic><topic>Harmonic analysis</topic><topic>Light emitting diodes</topic><topic>nonlinear load</topic><topic>Phase transformers</topic><topic>Power system harmonics</topic><topic>transformer losses</topic><topic>Universal Serial Bus</topic><topic>Voltage control</topic><topic>Windings</topic><toplevel>online_resources</toplevel><creatorcontrib>Soh, T. L. G.</creatorcontrib><creatorcontrib>Said, D. M.</creatorcontrib><creatorcontrib>Ahmad, N.</creatorcontrib><creatorcontrib>Nor, K. M.</creatorcontrib><creatorcontrib>Salim, F.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Soh, T. L. G.</au><au>Said, D. M.</au><au>Ahmad, N.</au><au>Nor, K. M.</au><au>Salim, F.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Experimental study on the impact of harmonics on transformer</atitle><btitle>2013 IEEE 7th International Power Engineering and Optimization Conference (PEOCO)</btitle><stitle>PEOCO</stitle><date>2013-06</date><risdate>2013</risdate><spage>686</spage><epage>690</epage><pages>686-690</pages><isbn>1467350729</isbn><isbn>9781467350723</isbn><eisbn>9781467350747</eisbn><eisbn>1467350745</eisbn><eisbn>1467350737</eisbn><eisbn>9781467350730</eisbn><abstract>Impacts of harmonics on step-down transformer are presented in this paper. Transformer failure had been reported due to harmonic current causing excessive winding temperature rise. Excessive temperature rise of transformer is due to harmonic effect result in higher power loss than normal operating mode. An experimental setup is proposed which allow for observation of harmonics. This research focuses on the transformer losses under nonlinear load with different power consumption. Moreover, the trends of Total Harmonic Distortion (THD) with nonlinear load are reported.</abstract><pub>IEEE</pub><doi>10.1109/PEOCO.2013.6564634</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISBN: 1467350729 |
ispartof | 2013 IEEE 7th International Power Engineering and Optimization Conference (PEOCO), 2013, p.686-690 |
issn | |
language | eng |
recordid | cdi_ieee_primary_6564634 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | efficiency harmonic Harmonic analysis Light emitting diodes nonlinear load Phase transformers Power system harmonics transformer losses Universal Serial Bus Voltage control Windings |
title | Experimental study on the impact of harmonics on transformer |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-12T22%3A44%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Experimental%20study%20on%20the%20impact%20of%20harmonics%20on%20transformer&rft.btitle=2013%20IEEE%207th%20International%20Power%20Engineering%20and%20Optimization%20Conference%20(PEOCO)&rft.au=Soh,%20T.%20L.%20G.&rft.date=2013-06&rft.spage=686&rft.epage=690&rft.pages=686-690&rft.isbn=1467350729&rft.isbn_list=9781467350723&rft_id=info:doi/10.1109/PEOCO.2013.6564634&rft_dat=%3Cieee_6IE%3E6564634%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781467350747&rft.eisbn_list=1467350745&rft.eisbn_list=1467350737&rft.eisbn_list=9781467350730&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6564634&rfr_iscdi=true |