An improved approach for transient thermal modeling using lumped parameter networks

For thermal modelling of electrical machines often lumped parameter thermal models are used. This simple lumped parameter approach leads to overestimation of temperatures when inner losses are present. A new approach is derived using a node shifting technique, compensating the temperature overpredic...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Kuehbacher, Daniel, Kelleter, Arndt, Gerling, Dieter
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:For thermal modelling of electrical machines often lumped parameter thermal models are used. This simple lumped parameter approach leads to overestimation of temperatures when inner losses are present. A new approach is derived using a node shifting technique, compensating the temperature overprediction and delivering the exact mean temperature in one dimensional cases. The application to a two dimensional lumped parameter model for electrical machines stator cross section is presented. The results for the one and two dimensional case are evaluated together with the basic lumped parameter approach and the common T-equivalent network compensation approach. It is shown that the desired compensation effect is achieved by the new model and that some disadvantages of the common compensation approach are avoided.