Dose-Free Monitoring of Radiotherapy Treatments With Scattered Photons: Concept and Simulation Study

Modern radiotherapy (RT) techniques provide increasingly higher conformality, a potential invaluable clinical benefit to the patient. Consequently, in both single and multi-fractionated RT, patient misalignments and changing internal anatomy are also becoming more critical since higher conformality...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on nuclear science 2013-08, Vol.60 (4), p.3119-3126
Hauptverfasser: Cunha, Micaela, Pinto, Marco, Simoes, Hugo, Ferreira, Brigida, do Carmo Lopes, Maria, Fonte, Paulo, Crespo, Paulo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 3126
container_issue 4
container_start_page 3119
container_title IEEE transactions on nuclear science
container_volume 60
creator Cunha, Micaela
Pinto, Marco
Simoes, Hugo
Ferreira, Brigida
do Carmo Lopes, Maria
Fonte, Paulo
Crespo, Paulo
description Modern radiotherapy (RT) techniques provide increasingly higher conformality, a potential invaluable clinical benefit to the patient. Consequently, in both single and multi-fractionated RT, patient misalignments and changing internal anatomy are also becoming more critical since higher conformality may equally represent a higher risk of target underdosage or organ-at-risk overdosage. Even with rigid fixation devices, maximum positioning errors higher than 1 cm are observable. In addition, anatomical morphological variations induced by cardiorespiratory or bowel motion, or RT-related biological responses, have been reported. The latter include tissue swelling, edema, inflammation, tumor shrinkage/growth, or filling of body cavities with unaccounted mucus or edematous tissue. State-of-the-art image-guided radiotherapy (IGRT) aims at providing feedback to the radiation oncologist in regard to these matters, some times at the cost of increased dosage (e.g. kilo and megavoltage IGRT), other times providing insufficient clinical information. We investigate a novel imaging system specially designed for monitoring both conventional and intensity/volumetric modulated photon radiotherapy (IMRT/VMRT, static and dynamic). The proof-of-principle and feasibility of such system indicate its potential for monitoring each field (and segment, for IMRT/VMRT) during all treatment fractions without whatsoever additional dose. We present a clear 2D correlation between the dose delivered in a heterogeneous phantom and the number of scattered photons detected perpendicular to the photon beam. Simulations of high-energy, multi-hole collimators show real-time, high-detectability of abnormal (though possible) irradiation scenarios with pertinent target morphological alterations, such as tumor dislocation or formation of edematous tissue.
doi_str_mv 10.1109/TNS.2013.2265159
format Article
fullrecord <record><control><sourceid>crossref_RIE</sourceid><recordid>TN_cdi_ieee_primary_6544308</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6544308</ieee_id><sourcerecordid>10_1109_TNS_2013_2265159</sourcerecordid><originalsourceid>FETCH-LOGICAL-c263t-1e64a6d2c23fd2a58cc0e8d1ddbaa507b8708a9af4cf1d398fd3d1571304cdc63</originalsourceid><addsrcrecordid>eNo9kE1LAzEYhIMoWKt3wUv-wNZ8bhNvUq0K9QO34nFJk3dtpE1Kkh76793S4mkYmBmYB6FrSkaUEn07f2tGjFA-YqyWVOoTNKBSqorKsTpFA0KoqrTQ-hxd5PzbWyGJHCD3EDNU0wSAX2PwJSYffnDs8KdxPpYlJLPZ4XkCU9YQSsbfvixxY00pkMDhj2UsMeQ7PInBwqZgExxu_Hq7MsXHgJuydbtLdNaZVYarow7R1_RxPnmuZu9PL5P7WWVZzUtFoRamdswy3jlmpLKWgHLUuYUxkowXakyU0aYTtqOOa9U57vp_lBNhna35EJHDrk0x5wRdu0l-bdKupaTdU2p7Su2eUnuk1FduDhUPAP_xWgrBieJ_47Zlog</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Dose-Free Monitoring of Radiotherapy Treatments With Scattered Photons: Concept and Simulation Study</title><source>IEEE Electronic Library (IEL)</source><creator>Cunha, Micaela ; Pinto, Marco ; Simoes, Hugo ; Ferreira, Brigida ; do Carmo Lopes, Maria ; Fonte, Paulo ; Crespo, Paulo</creator><creatorcontrib>Cunha, Micaela ; Pinto, Marco ; Simoes, Hugo ; Ferreira, Brigida ; do Carmo Lopes, Maria ; Fonte, Paulo ; Crespo, Paulo</creatorcontrib><description>Modern radiotherapy (RT) techniques provide increasingly higher conformality, a potential invaluable clinical benefit to the patient. Consequently, in both single and multi-fractionated RT, patient misalignments and changing internal anatomy are also becoming more critical since higher conformality may equally represent a higher risk of target underdosage or organ-at-risk overdosage. Even with rigid fixation devices, maximum positioning errors higher than 1 cm are observable. In addition, anatomical morphological variations induced by cardiorespiratory or bowel motion, or RT-related biological responses, have been reported. The latter include tissue swelling, edema, inflammation, tumor shrinkage/growth, or filling of body cavities with unaccounted mucus or edematous tissue. State-of-the-art image-guided radiotherapy (IGRT) aims at providing feedback to the radiation oncologist in regard to these matters, some times at the cost of increased dosage (e.g. kilo and megavoltage IGRT), other times providing insufficient clinical information. We investigate a novel imaging system specially designed for monitoring both conventional and intensity/volumetric modulated photon radiotherapy (IMRT/VMRT, static and dynamic). The proof-of-principle and feasibility of such system indicate its potential for monitoring each field (and segment, for IMRT/VMRT) during all treatment fractions without whatsoever additional dose. We present a clear 2D correlation between the dose delivered in a heterogeneous phantom and the number of scattered photons detected perpendicular to the photon beam. Simulations of high-energy, multi-hole collimators show real-time, high-detectability of abnormal (though possible) irradiation scenarios with pertinent target morphological alterations, such as tumor dislocation or formation of edematous tissue.</description><identifier>ISSN: 0018-9499</identifier><identifier>EISSN: 1558-1578</identifier><identifier>DOI: 10.1109/TNS.2013.2265159</identifier><identifier>CODEN: IETNAE</identifier><language>eng</language><publisher>IEEE</publisher><subject>Collimators ; Compton scattering ; Detectors ; dosimetry ; gamma-ray cameras ; medical imaging ; Monitoring ; Monte Carlo simulation ; Phantoms ; Photonics ; Radiation effects ; radiation imaging ; real time systems ; therapy ; Tumors</subject><ispartof>IEEE transactions on nuclear science, 2013-08, Vol.60 (4), p.3119-3126</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c263t-1e64a6d2c23fd2a58cc0e8d1ddbaa507b8708a9af4cf1d398fd3d1571304cdc63</citedby><cites>FETCH-LOGICAL-c263t-1e64a6d2c23fd2a58cc0e8d1ddbaa507b8708a9af4cf1d398fd3d1571304cdc63</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6544308$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>315,781,785,797,27929,27930,54763</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6544308$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Cunha, Micaela</creatorcontrib><creatorcontrib>Pinto, Marco</creatorcontrib><creatorcontrib>Simoes, Hugo</creatorcontrib><creatorcontrib>Ferreira, Brigida</creatorcontrib><creatorcontrib>do Carmo Lopes, Maria</creatorcontrib><creatorcontrib>Fonte, Paulo</creatorcontrib><creatorcontrib>Crespo, Paulo</creatorcontrib><title>Dose-Free Monitoring of Radiotherapy Treatments With Scattered Photons: Concept and Simulation Study</title><title>IEEE transactions on nuclear science</title><addtitle>TNS</addtitle><description>Modern radiotherapy (RT) techniques provide increasingly higher conformality, a potential invaluable clinical benefit to the patient. Consequently, in both single and multi-fractionated RT, patient misalignments and changing internal anatomy are also becoming more critical since higher conformality may equally represent a higher risk of target underdosage or organ-at-risk overdosage. Even with rigid fixation devices, maximum positioning errors higher than 1 cm are observable. In addition, anatomical morphological variations induced by cardiorespiratory or bowel motion, or RT-related biological responses, have been reported. The latter include tissue swelling, edema, inflammation, tumor shrinkage/growth, or filling of body cavities with unaccounted mucus or edematous tissue. State-of-the-art image-guided radiotherapy (IGRT) aims at providing feedback to the radiation oncologist in regard to these matters, some times at the cost of increased dosage (e.g. kilo and megavoltage IGRT), other times providing insufficient clinical information. We investigate a novel imaging system specially designed for monitoring both conventional and intensity/volumetric modulated photon radiotherapy (IMRT/VMRT, static and dynamic). The proof-of-principle and feasibility of such system indicate its potential for monitoring each field (and segment, for IMRT/VMRT) during all treatment fractions without whatsoever additional dose. We present a clear 2D correlation between the dose delivered in a heterogeneous phantom and the number of scattered photons detected perpendicular to the photon beam. Simulations of high-energy, multi-hole collimators show real-time, high-detectability of abnormal (though possible) irradiation scenarios with pertinent target morphological alterations, such as tumor dislocation or formation of edematous tissue.</description><subject>Collimators</subject><subject>Compton scattering</subject><subject>Detectors</subject><subject>dosimetry</subject><subject>gamma-ray cameras</subject><subject>medical imaging</subject><subject>Monitoring</subject><subject>Monte Carlo simulation</subject><subject>Phantoms</subject><subject>Photonics</subject><subject>Radiation effects</subject><subject>radiation imaging</subject><subject>real time systems</subject><subject>therapy</subject><subject>Tumors</subject><issn>0018-9499</issn><issn>1558-1578</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNo9kE1LAzEYhIMoWKt3wUv-wNZ8bhNvUq0K9QO34nFJk3dtpE1Kkh76793S4mkYmBmYB6FrSkaUEn07f2tGjFA-YqyWVOoTNKBSqorKsTpFA0KoqrTQ-hxd5PzbWyGJHCD3EDNU0wSAX2PwJSYffnDs8KdxPpYlJLPZ4XkCU9YQSsbfvixxY00pkMDhj2UsMeQ7PInBwqZgExxu_Hq7MsXHgJuydbtLdNaZVYarow7R1_RxPnmuZu9PL5P7WWVZzUtFoRamdswy3jlmpLKWgHLUuYUxkowXakyU0aYTtqOOa9U57vp_lBNhna35EJHDrk0x5wRdu0l-bdKupaTdU2p7Su2eUnuk1FduDhUPAP_xWgrBieJ_47Zlog</recordid><startdate>20130801</startdate><enddate>20130801</enddate><creator>Cunha, Micaela</creator><creator>Pinto, Marco</creator><creator>Simoes, Hugo</creator><creator>Ferreira, Brigida</creator><creator>do Carmo Lopes, Maria</creator><creator>Fonte, Paulo</creator><creator>Crespo, Paulo</creator><general>IEEE</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20130801</creationdate><title>Dose-Free Monitoring of Radiotherapy Treatments With Scattered Photons: Concept and Simulation Study</title><author>Cunha, Micaela ; Pinto, Marco ; Simoes, Hugo ; Ferreira, Brigida ; do Carmo Lopes, Maria ; Fonte, Paulo ; Crespo, Paulo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c263t-1e64a6d2c23fd2a58cc0e8d1ddbaa507b8708a9af4cf1d398fd3d1571304cdc63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Collimators</topic><topic>Compton scattering</topic><topic>Detectors</topic><topic>dosimetry</topic><topic>gamma-ray cameras</topic><topic>medical imaging</topic><topic>Monitoring</topic><topic>Monte Carlo simulation</topic><topic>Phantoms</topic><topic>Photonics</topic><topic>Radiation effects</topic><topic>radiation imaging</topic><topic>real time systems</topic><topic>therapy</topic><topic>Tumors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cunha, Micaela</creatorcontrib><creatorcontrib>Pinto, Marco</creatorcontrib><creatorcontrib>Simoes, Hugo</creatorcontrib><creatorcontrib>Ferreira, Brigida</creatorcontrib><creatorcontrib>do Carmo Lopes, Maria</creatorcontrib><creatorcontrib>Fonte, Paulo</creatorcontrib><creatorcontrib>Crespo, Paulo</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><jtitle>IEEE transactions on nuclear science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Cunha, Micaela</au><au>Pinto, Marco</au><au>Simoes, Hugo</au><au>Ferreira, Brigida</au><au>do Carmo Lopes, Maria</au><au>Fonte, Paulo</au><au>Crespo, Paulo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Dose-Free Monitoring of Radiotherapy Treatments With Scattered Photons: Concept and Simulation Study</atitle><jtitle>IEEE transactions on nuclear science</jtitle><stitle>TNS</stitle><date>2013-08-01</date><risdate>2013</risdate><volume>60</volume><issue>4</issue><spage>3119</spage><epage>3126</epage><pages>3119-3126</pages><issn>0018-9499</issn><eissn>1558-1578</eissn><coden>IETNAE</coden><abstract>Modern radiotherapy (RT) techniques provide increasingly higher conformality, a potential invaluable clinical benefit to the patient. Consequently, in both single and multi-fractionated RT, patient misalignments and changing internal anatomy are also becoming more critical since higher conformality may equally represent a higher risk of target underdosage or organ-at-risk overdosage. Even with rigid fixation devices, maximum positioning errors higher than 1 cm are observable. In addition, anatomical morphological variations induced by cardiorespiratory or bowel motion, or RT-related biological responses, have been reported. The latter include tissue swelling, edema, inflammation, tumor shrinkage/growth, or filling of body cavities with unaccounted mucus or edematous tissue. State-of-the-art image-guided radiotherapy (IGRT) aims at providing feedback to the radiation oncologist in regard to these matters, some times at the cost of increased dosage (e.g. kilo and megavoltage IGRT), other times providing insufficient clinical information. We investigate a novel imaging system specially designed for monitoring both conventional and intensity/volumetric modulated photon radiotherapy (IMRT/VMRT, static and dynamic). The proof-of-principle and feasibility of such system indicate its potential for monitoring each field (and segment, for IMRT/VMRT) during all treatment fractions without whatsoever additional dose. We present a clear 2D correlation between the dose delivered in a heterogeneous phantom and the number of scattered photons detected perpendicular to the photon beam. Simulations of high-energy, multi-hole collimators show real-time, high-detectability of abnormal (though possible) irradiation scenarios with pertinent target morphological alterations, such as tumor dislocation or formation of edematous tissue.</abstract><pub>IEEE</pub><doi>10.1109/TNS.2013.2265159</doi><tpages>8</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0018-9499
ispartof IEEE transactions on nuclear science, 2013-08, Vol.60 (4), p.3119-3126
issn 0018-9499
1558-1578
language eng
recordid cdi_ieee_primary_6544308
source IEEE Electronic Library (IEL)
subjects Collimators
Compton scattering
Detectors
dosimetry
gamma-ray cameras
medical imaging
Monitoring
Monte Carlo simulation
Phantoms
Photonics
Radiation effects
radiation imaging
real time systems
therapy
Tumors
title Dose-Free Monitoring of Radiotherapy Treatments With Scattered Photons: Concept and Simulation Study
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-15T07%3A45%3A33IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Dose-Free%20Monitoring%20of%20Radiotherapy%20Treatments%20With%20Scattered%20Photons:%20Concept%20and%20Simulation%20Study&rft.jtitle=IEEE%20transactions%20on%20nuclear%20science&rft.au=Cunha,%20Micaela&rft.date=2013-08-01&rft.volume=60&rft.issue=4&rft.spage=3119&rft.epage=3126&rft.pages=3119-3126&rft.issn=0018-9499&rft.eissn=1558-1578&rft.coden=IETNAE&rft_id=info:doi/10.1109/TNS.2013.2265159&rft_dat=%3Ccrossref_RIE%3E10_1109_TNS_2013_2265159%3C/crossref_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6544308&rfr_iscdi=true