Medium frequency transformers for solid-state-transformer applications - Design and experimental verification
Solid-state-transformer technology pushes the specifications of electric transformers in the high-power medium-frequency range. This combination results in larger-sized transformers operating at higher frequencies whereby parasitic phenomenon should be carefully accounted for. This paper presents an...
Gespeichert in:
Hauptverfasser: | , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1290 |
---|---|
container_issue | |
container_start_page | 1285 |
container_title | |
container_volume | |
creator | Ortiz, G. Leibl, M. Kolar, J. W. Apeldoorn, O. |
description | Solid-state-transformer technology pushes the specifications of electric transformers in the high-power medium-frequency range. This combination results in larger-sized transformers operating at higher frequencies whereby parasitic phenomenon should be carefully accounted for. This paper presents an analytical description of the limiting factors and the connection between frequency/power rating and the available core and copper conductor technology on the power density and efficiency of medium-frequency transformers. Furthermore, two designed transformers for 166kW/20kHz based on two different core materials and cooling systems are presented. Extensive copper, core and cooling system loss measurements on one of these transformers are discussed in order to analyze the transformers' behavior from a practical point of view. |
doi_str_mv | 10.1109/PEDS.2013.6527217 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6527217</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6527217</ieee_id><sourcerecordid>6527217</sourcerecordid><originalsourceid>FETCH-LOGICAL-c289t-1c8d2b06ecfce22b6777654de8b371aec8a99ba79b475d67d729d4b68a32f81a3</originalsourceid><addsrcrecordid>eNpVUM1KAzEYjKhgqX0A8ZIXSE2yu_mSo7T1ByoK6rl8Sb6VwO523WzFvr0Fe9DTzDDDMAxjV0rOlZLu5mW1fJ1rqYq5qTRoBSds5sCq0kChwCk4_aelPGMTrUwpKl2ZCzbLOXkpbSWhtGbC2ieKadfyeqDPHXVhz8cBu1xvh5aGzA_I87ZJUeQRRxJ_TI5936SAY9p2mQu-pJw-Oo5d5PTd05Ba6kZs-NeB1sfcJTuvsck0O-KUvd-t3hYPYv18_7i4XYugrRuFCjZqLw2FOpDW3gCAqcpI1hegkIJF5zyC8yVU0UAE7WLpjcVC11ZhMWXXv72JiDb9YQsO-83xsOIHYcBfrQ</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Medium frequency transformers for solid-state-transformer applications - Design and experimental verification</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Ortiz, G. ; Leibl, M. ; Kolar, J. W. ; Apeldoorn, O.</creator><creatorcontrib>Ortiz, G. ; Leibl, M. ; Kolar, J. W. ; Apeldoorn, O.</creatorcontrib><description>Solid-state-transformer technology pushes the specifications of electric transformers in the high-power medium-frequency range. This combination results in larger-sized transformers operating at higher frequencies whereby parasitic phenomenon should be carefully accounted for. This paper presents an analytical description of the limiting factors and the connection between frequency/power rating and the available core and copper conductor technology on the power density and efficiency of medium-frequency transformers. Furthermore, two designed transformers for 166kW/20kHz based on two different core materials and cooling systems are presented. Extensive copper, core and cooling system loss measurements on one of these transformers are discussed in order to analyze the transformers' behavior from a practical point of view.</description><identifier>ISSN: 2164-5256</identifier><identifier>ISBN: 9781467317900</identifier><identifier>ISBN: 146731790X</identifier><identifier>EISBN: 9781467317917</identifier><identifier>EISBN: 9781467317924</identifier><identifier>EISBN: 1467317918</identifier><identifier>EISBN: 1467317926</identifier><identifier>DOI: 10.1109/PEDS.2013.6527217</identifier><language>eng</language><publisher>IEEE</publisher><subject>Cooling ; Density measurement ; Loss measurement ; Power system measurements ; Transformer cores ; Windings ; Wires</subject><ispartof>2013 IEEE 10th International Conference on Power Electronics and Drive Systems (PEDS), 2013, p.1285-1290</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c289t-1c8d2b06ecfce22b6777654de8b371aec8a99ba79b475d67d729d4b68a32f81a3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6527217$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6527217$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Ortiz, G.</creatorcontrib><creatorcontrib>Leibl, M.</creatorcontrib><creatorcontrib>Kolar, J. W.</creatorcontrib><creatorcontrib>Apeldoorn, O.</creatorcontrib><title>Medium frequency transformers for solid-state-transformer applications - Design and experimental verification</title><title>2013 IEEE 10th International Conference on Power Electronics and Drive Systems (PEDS)</title><addtitle>PEDS</addtitle><description>Solid-state-transformer technology pushes the specifications of electric transformers in the high-power medium-frequency range. This combination results in larger-sized transformers operating at higher frequencies whereby parasitic phenomenon should be carefully accounted for. This paper presents an analytical description of the limiting factors and the connection between frequency/power rating and the available core and copper conductor technology on the power density and efficiency of medium-frequency transformers. Furthermore, two designed transformers for 166kW/20kHz based on two different core materials and cooling systems are presented. Extensive copper, core and cooling system loss measurements on one of these transformers are discussed in order to analyze the transformers' behavior from a practical point of view.</description><subject>Cooling</subject><subject>Density measurement</subject><subject>Loss measurement</subject><subject>Power system measurements</subject><subject>Transformer cores</subject><subject>Windings</subject><subject>Wires</subject><issn>2164-5256</issn><isbn>9781467317900</isbn><isbn>146731790X</isbn><isbn>9781467317917</isbn><isbn>9781467317924</isbn><isbn>1467317918</isbn><isbn>1467317926</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2013</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNpVUM1KAzEYjKhgqX0A8ZIXSE2yu_mSo7T1ByoK6rl8Sb6VwO523WzFvr0Fe9DTzDDDMAxjV0rOlZLu5mW1fJ1rqYq5qTRoBSds5sCq0kChwCk4_aelPGMTrUwpKl2ZCzbLOXkpbSWhtGbC2ieKadfyeqDPHXVhz8cBu1xvh5aGzA_I87ZJUeQRRxJ_TI5936SAY9p2mQu-pJw-Oo5d5PTd05Ba6kZs-NeB1sfcJTuvsck0O-KUvd-t3hYPYv18_7i4XYugrRuFCjZqLw2FOpDW3gCAqcpI1hegkIJF5zyC8yVU0UAE7WLpjcVC11ZhMWXXv72JiDb9YQsO-83xsOIHYcBfrQ</recordid><startdate>201304</startdate><enddate>201304</enddate><creator>Ortiz, G.</creator><creator>Leibl, M.</creator><creator>Kolar, J. W.</creator><creator>Apeldoorn, O.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201304</creationdate><title>Medium frequency transformers for solid-state-transformer applications - Design and experimental verification</title><author>Ortiz, G. ; Leibl, M. ; Kolar, J. W. ; Apeldoorn, O.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c289t-1c8d2b06ecfce22b6777654de8b371aec8a99ba79b475d67d729d4b68a32f81a3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Cooling</topic><topic>Density measurement</topic><topic>Loss measurement</topic><topic>Power system measurements</topic><topic>Transformer cores</topic><topic>Windings</topic><topic>Wires</topic><toplevel>online_resources</toplevel><creatorcontrib>Ortiz, G.</creatorcontrib><creatorcontrib>Leibl, M.</creatorcontrib><creatorcontrib>Kolar, J. W.</creatorcontrib><creatorcontrib>Apeldoorn, O.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Ortiz, G.</au><au>Leibl, M.</au><au>Kolar, J. W.</au><au>Apeldoorn, O.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Medium frequency transformers for solid-state-transformer applications - Design and experimental verification</atitle><btitle>2013 IEEE 10th International Conference on Power Electronics and Drive Systems (PEDS)</btitle><stitle>PEDS</stitle><date>2013-04</date><risdate>2013</risdate><spage>1285</spage><epage>1290</epage><pages>1285-1290</pages><issn>2164-5256</issn><isbn>9781467317900</isbn><isbn>146731790X</isbn><eisbn>9781467317917</eisbn><eisbn>9781467317924</eisbn><eisbn>1467317918</eisbn><eisbn>1467317926</eisbn><abstract>Solid-state-transformer technology pushes the specifications of electric transformers in the high-power medium-frequency range. This combination results in larger-sized transformers operating at higher frequencies whereby parasitic phenomenon should be carefully accounted for. This paper presents an analytical description of the limiting factors and the connection between frequency/power rating and the available core and copper conductor technology on the power density and efficiency of medium-frequency transformers. Furthermore, two designed transformers for 166kW/20kHz based on two different core materials and cooling systems are presented. Extensive copper, core and cooling system loss measurements on one of these transformers are discussed in order to analyze the transformers' behavior from a practical point of view.</abstract><pub>IEEE</pub><doi>10.1109/PEDS.2013.6527217</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 2164-5256 |
ispartof | 2013 IEEE 10th International Conference on Power Electronics and Drive Systems (PEDS), 2013, p.1285-1290 |
issn | 2164-5256 |
language | eng |
recordid | cdi_ieee_primary_6527217 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Cooling Density measurement Loss measurement Power system measurements Transformer cores Windings Wires |
title | Medium frequency transformers for solid-state-transformer applications - Design and experimental verification |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T00%3A46%3A54IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Medium%20frequency%20transformers%20for%20solid-state-transformer%20applications%20-%20Design%20and%20experimental%20verification&rft.btitle=2013%20IEEE%2010th%20International%20Conference%20on%20Power%20Electronics%20and%20Drive%20Systems%20(PEDS)&rft.au=Ortiz,%20G.&rft.date=2013-04&rft.spage=1285&rft.epage=1290&rft.pages=1285-1290&rft.issn=2164-5256&rft.isbn=9781467317900&rft.isbn_list=146731790X&rft_id=info:doi/10.1109/PEDS.2013.6527217&rft_dat=%3Cieee_6IE%3E6527217%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781467317917&rft.eisbn_list=9781467317924&rft.eisbn_list=1467317918&rft.eisbn_list=1467317926&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6527217&rfr_iscdi=true |