Mobile Application for Impedance-Based Biomimetic Sensor Readout

A new method is presented for smartphone-based impedance spectroscopy, especially fine-tuned for biomimetic sensor readout. Complete user control is given by means of an app while the on-board audio hardware of the smartphone or tablet PC is used to perform impedance measurements. This considerably...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE sensors journal 2013-07, Vol.13 (7), p.2659-2665
Hauptverfasser: Broeders, J., Croux, D., Peeters, M., Beyens, T., Duchateau, S., Cleij, T. J., Wagner, P., Thoelen, R., De Ceuninck, W.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2665
container_issue 7
container_start_page 2659
container_title IEEE sensors journal
container_volume 13
creator Broeders, J.
Croux, D.
Peeters, M.
Beyens, T.
Duchateau, S.
Cleij, T. J.
Wagner, P.
Thoelen, R.
De Ceuninck, W.
description A new method is presented for smartphone-based impedance spectroscopy, especially fine-tuned for biomimetic sensor readout. Complete user control is given by means of an app while the on-board audio hardware of the smartphone or tablet PC is used to perform impedance measurements. This considerably limits the required external hardware. Disposable test strips can be mounted for convenient readout of various sensors. The system is verified on passive components and a synthetic molecularly imprinted polymer histamine sensor. The prototype design could prove a useful step toward the development of home-diagnostics biosensing applications.
doi_str_mv 10.1109/JSEN.2013.2256346
format Article
fullrecord <record><control><sourceid>crossref_RIE</sourceid><recordid>TN_cdi_ieee_primary_6493374</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6493374</ieee_id><sourcerecordid>10_1109_JSEN_2013_2256346</sourcerecordid><originalsourceid>FETCH-LOGICAL-c308t-d65e35e56db1f746b1e0fcb77c2c02782613861f3cca14542ce2e6cc633961293</originalsourceid><addsrcrecordid>eNo9kM1Kw0AUhQdRsFYfQNzkBVLnzp2fZGdbqlaqglVwFyY3NzDSNCETF769DRZX5yzOdxafENcgZwAyv33arl5mSgLOlDIWtT0REzAmS8Hp7HTsKFON7vNcXMT4JSXkzriJuHtuy7DjZN51u0B-CO0-qds-WTcdV35PnC585CpZhLYJDQ-Bki3v42Hxxr5qv4dLcVb7XeSrY07Fx_3qffmYbl4f1sv5JiWU2ZBW1jAaNrYqoXbalsCyptI5UiSVy5QFzCzUSORBG62IFVsii5hbUDlOBfz9Ut_G2HNddH1ofP9TgCxGBcWooBgVFEcFB-bmjwnM_L-3Okd0Gn8BJ8pXSA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Mobile Application for Impedance-Based Biomimetic Sensor Readout</title><source>IEEE Electronic Library (IEL)</source><creator>Broeders, J. ; Croux, D. ; Peeters, M. ; Beyens, T. ; Duchateau, S. ; Cleij, T. J. ; Wagner, P. ; Thoelen, R. ; De Ceuninck, W.</creator><creatorcontrib>Broeders, J. ; Croux, D. ; Peeters, M. ; Beyens, T. ; Duchateau, S. ; Cleij, T. J. ; Wagner, P. ; Thoelen, R. ; De Ceuninck, W.</creatorcontrib><description>A new method is presented for smartphone-based impedance spectroscopy, especially fine-tuned for biomimetic sensor readout. Complete user control is given by means of an app while the on-board audio hardware of the smartphone or tablet PC is used to perform impedance measurements. This considerably limits the required external hardware. Disposable test strips can be mounted for convenient readout of various sensors. The system is verified on passive components and a synthetic molecularly imprinted polymer histamine sensor. The prototype design could prove a useful step toward the development of home-diagnostics biosensing applications.</description><identifier>ISSN: 1530-437X</identifier><identifier>EISSN: 1558-1748</identifier><identifier>DOI: 10.1109/JSEN.2013.2256346</identifier><identifier>CODEN: ISJEAZ</identifier><language>eng</language><publisher>IEEE</publisher><subject>Biomimetic sensors ; impedance spectroscopy ; molecular imprinting ; smartphone</subject><ispartof>IEEE sensors journal, 2013-07, Vol.13 (7), p.2659-2665</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c308t-d65e35e56db1f746b1e0fcb77c2c02782613861f3cca14542ce2e6cc633961293</citedby><cites>FETCH-LOGICAL-c308t-d65e35e56db1f746b1e0fcb77c2c02782613861f3cca14542ce2e6cc633961293</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6493374$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,776,780,792,27901,27902,54733</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6493374$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Broeders, J.</creatorcontrib><creatorcontrib>Croux, D.</creatorcontrib><creatorcontrib>Peeters, M.</creatorcontrib><creatorcontrib>Beyens, T.</creatorcontrib><creatorcontrib>Duchateau, S.</creatorcontrib><creatorcontrib>Cleij, T. J.</creatorcontrib><creatorcontrib>Wagner, P.</creatorcontrib><creatorcontrib>Thoelen, R.</creatorcontrib><creatorcontrib>De Ceuninck, W.</creatorcontrib><title>Mobile Application for Impedance-Based Biomimetic Sensor Readout</title><title>IEEE sensors journal</title><addtitle>JSEN</addtitle><description>A new method is presented for smartphone-based impedance spectroscopy, especially fine-tuned for biomimetic sensor readout. Complete user control is given by means of an app while the on-board audio hardware of the smartphone or tablet PC is used to perform impedance measurements. This considerably limits the required external hardware. Disposable test strips can be mounted for convenient readout of various sensors. The system is verified on passive components and a synthetic molecularly imprinted polymer histamine sensor. The prototype design could prove a useful step toward the development of home-diagnostics biosensing applications.</description><subject>Biomimetic sensors</subject><subject>impedance spectroscopy</subject><subject>molecular imprinting</subject><subject>smartphone</subject><issn>1530-437X</issn><issn>1558-1748</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNo9kM1Kw0AUhQdRsFYfQNzkBVLnzp2fZGdbqlaqglVwFyY3NzDSNCETF769DRZX5yzOdxafENcgZwAyv33arl5mSgLOlDIWtT0REzAmS8Hp7HTsKFON7vNcXMT4JSXkzriJuHtuy7DjZN51u0B-CO0-qds-WTcdV35PnC585CpZhLYJDQ-Bki3v42Hxxr5qv4dLcVb7XeSrY07Fx_3qffmYbl4f1sv5JiWU2ZBW1jAaNrYqoXbalsCyptI5UiSVy5QFzCzUSORBG62IFVsii5hbUDlOBfz9Ut_G2HNddH1ofP9TgCxGBcWooBgVFEcFB-bmjwnM_L-3Okd0Gn8BJ8pXSA</recordid><startdate>20130701</startdate><enddate>20130701</enddate><creator>Broeders, J.</creator><creator>Croux, D.</creator><creator>Peeters, M.</creator><creator>Beyens, T.</creator><creator>Duchateau, S.</creator><creator>Cleij, T. J.</creator><creator>Wagner, P.</creator><creator>Thoelen, R.</creator><creator>De Ceuninck, W.</creator><general>IEEE</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20130701</creationdate><title>Mobile Application for Impedance-Based Biomimetic Sensor Readout</title><author>Broeders, J. ; Croux, D. ; Peeters, M. ; Beyens, T. ; Duchateau, S. ; Cleij, T. J. ; Wagner, P. ; Thoelen, R. ; De Ceuninck, W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c308t-d65e35e56db1f746b1e0fcb77c2c02782613861f3cca14542ce2e6cc633961293</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Biomimetic sensors</topic><topic>impedance spectroscopy</topic><topic>molecular imprinting</topic><topic>smartphone</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Broeders, J.</creatorcontrib><creatorcontrib>Croux, D.</creatorcontrib><creatorcontrib>Peeters, M.</creatorcontrib><creatorcontrib>Beyens, T.</creatorcontrib><creatorcontrib>Duchateau, S.</creatorcontrib><creatorcontrib>Cleij, T. J.</creatorcontrib><creatorcontrib>Wagner, P.</creatorcontrib><creatorcontrib>Thoelen, R.</creatorcontrib><creatorcontrib>De Ceuninck, W.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><jtitle>IEEE sensors journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Broeders, J.</au><au>Croux, D.</au><au>Peeters, M.</au><au>Beyens, T.</au><au>Duchateau, S.</au><au>Cleij, T. J.</au><au>Wagner, P.</au><au>Thoelen, R.</au><au>De Ceuninck, W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Mobile Application for Impedance-Based Biomimetic Sensor Readout</atitle><jtitle>IEEE sensors journal</jtitle><stitle>JSEN</stitle><date>2013-07-01</date><risdate>2013</risdate><volume>13</volume><issue>7</issue><spage>2659</spage><epage>2665</epage><pages>2659-2665</pages><issn>1530-437X</issn><eissn>1558-1748</eissn><coden>ISJEAZ</coden><abstract>A new method is presented for smartphone-based impedance spectroscopy, especially fine-tuned for biomimetic sensor readout. Complete user control is given by means of an app while the on-board audio hardware of the smartphone or tablet PC is used to perform impedance measurements. This considerably limits the required external hardware. Disposable test strips can be mounted for convenient readout of various sensors. The system is verified on passive components and a synthetic molecularly imprinted polymer histamine sensor. The prototype design could prove a useful step toward the development of home-diagnostics biosensing applications.</abstract><pub>IEEE</pub><doi>10.1109/JSEN.2013.2256346</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1530-437X
ispartof IEEE sensors journal, 2013-07, Vol.13 (7), p.2659-2665
issn 1530-437X
1558-1748
language eng
recordid cdi_ieee_primary_6493374
source IEEE Electronic Library (IEL)
subjects Biomimetic sensors
impedance spectroscopy
molecular imprinting
smartphone
title Mobile Application for Impedance-Based Biomimetic Sensor Readout
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T07%3A55%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Mobile%20Application%20for%20Impedance-Based%20Biomimetic%20Sensor%20Readout&rft.jtitle=IEEE%20sensors%20journal&rft.au=Broeders,%20J.&rft.date=2013-07-01&rft.volume=13&rft.issue=7&rft.spage=2659&rft.epage=2665&rft.pages=2659-2665&rft.issn=1530-437X&rft.eissn=1558-1748&rft.coden=ISJEAZ&rft_id=info:doi/10.1109/JSEN.2013.2256346&rft_dat=%3Ccrossref_RIE%3E10_1109_JSEN_2013_2256346%3C/crossref_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6493374&rfr_iscdi=true