Centralized BESS control to minimize demand of PV-supplied micro-grid under voltage constraints

Developments in inverter technology are resulting in distributed generation units built as a combination of a renewable source or energy storage device and an inverter, and such units are increasingly being used in micro-grids. One advantage of this combination is quick power response, allowing for...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Khoa Le Dinh, Hayashi, Y.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 869
container_issue
container_start_page 864
container_title
container_volume
creator Khoa Le Dinh
Hayashi, Y.
description Developments in inverter technology are resulting in distributed generation units built as a combination of a renewable source or energy storage device and an inverter, and such units are increasingly being used in micro-grids. One advantage of this combination is quick power response, allowing for complex control solutions. This paper presents a control method for battery energy storage systems which minimizes power flow from the utility to micro-grids through an interconnection point, and that limits local bus voltages in middle-voltage 6.6 KV micro-grids, such as those supplied by photovoltaic systems and the utility. Micro-grid loop and radial structures are studied to evaluate the effectiveness of the proposed method. MATLAB/Simulink is used to simulate the micro-grid model using actual photovoltaic data and residential loads from Ota City, Japan.
doi_str_mv 10.1109/PECon.2012.6450297
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6450297</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6450297</ieee_id><sourcerecordid>6450297</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-f3b2c35fca5b181907fe7b0c3fc4bf8af66cbdb80010b73842f469f5bcfc8b113</originalsourceid><addsrcrecordid>eNo1kNtKxDAURSMiqGN_QF_yAx2T5tpHLfUCAw6M-lpyHSJtU5KOoF9vxfHpcPbeZ7E5AFxjtMYY1bfbtonjukK4WnPKUFWLE3CJKReEISzpKShqIf93Qc9BkfMHQmg55lKIC9A1bpyT6sO3s_C-3e2giYsQezhHOIQxDIsDrRvUaGH0cPte5sM09WGJD8GkWO5TsPAwWpfgZ-xntXe_iLxAwzjnK3DmVZ9dcZwr8PbQvjZP5ebl8bm525QBCzaXnujKEOaNYhpLXCPhndDIEG-o9lJ5zo22Wi7NkRZE0spTXnumjTdSY0xW4OaPG5xz3ZTCoNJXd_wJ-QHdXFdQ</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Centralized BESS control to minimize demand of PV-supplied micro-grid under voltage constraints</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Khoa Le Dinh ; Hayashi, Y.</creator><creatorcontrib>Khoa Le Dinh ; Hayashi, Y.</creatorcontrib><description>Developments in inverter technology are resulting in distributed generation units built as a combination of a renewable source or energy storage device and an inverter, and such units are increasingly being used in micro-grids. One advantage of this combination is quick power response, allowing for complex control solutions. This paper presents a control method for battery energy storage systems which minimizes power flow from the utility to micro-grids through an interconnection point, and that limits local bus voltages in middle-voltage 6.6 KV micro-grids, such as those supplied by photovoltaic systems and the utility. Micro-grid loop and radial structures are studied to evaluate the effectiveness of the proposed method. MATLAB/Simulink is used to simulate the micro-grid model using actual photovoltaic data and residential loads from Ota City, Japan.</description><identifier>ISBN: 9781467350174</identifier><identifier>ISBN: 1467350176</identifier><identifier>EISBN: 1467350184</identifier><identifier>EISBN: 9781467350181</identifier><identifier>EISBN: 9781467350198</identifier><identifier>EISBN: 1467350192</identifier><identifier>DOI: 10.1109/PECon.2012.6450297</identifier><language>eng</language><publisher>IEEE</publisher><subject>Batteries ; battery energy storage system ; compensation ; inverter-based ; Load flow ; Load modeling ; PV system ; Reactive power ; System-on-a-chip ; Voltage control</subject><ispartof>2012 IEEE International Conference on Power and Energy (PECon), 2012, p.864-869</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6450297$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,777,781,786,787,2052,27906,54901</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6450297$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Khoa Le Dinh</creatorcontrib><creatorcontrib>Hayashi, Y.</creatorcontrib><title>Centralized BESS control to minimize demand of PV-supplied micro-grid under voltage constraints</title><title>2012 IEEE International Conference on Power and Energy (PECon)</title><addtitle>PECon</addtitle><description>Developments in inverter technology are resulting in distributed generation units built as a combination of a renewable source or energy storage device and an inverter, and such units are increasingly being used in micro-grids. One advantage of this combination is quick power response, allowing for complex control solutions. This paper presents a control method for battery energy storage systems which minimizes power flow from the utility to micro-grids through an interconnection point, and that limits local bus voltages in middle-voltage 6.6 KV micro-grids, such as those supplied by photovoltaic systems and the utility. Micro-grid loop and radial structures are studied to evaluate the effectiveness of the proposed method. MATLAB/Simulink is used to simulate the micro-grid model using actual photovoltaic data and residential loads from Ota City, Japan.</description><subject>Batteries</subject><subject>battery energy storage system</subject><subject>compensation</subject><subject>inverter-based</subject><subject>Load flow</subject><subject>Load modeling</subject><subject>PV system</subject><subject>Reactive power</subject><subject>System-on-a-chip</subject><subject>Voltage control</subject><isbn>9781467350174</isbn><isbn>1467350176</isbn><isbn>1467350184</isbn><isbn>9781467350181</isbn><isbn>9781467350198</isbn><isbn>1467350192</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2012</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo1kNtKxDAURSMiqGN_QF_yAx2T5tpHLfUCAw6M-lpyHSJtU5KOoF9vxfHpcPbeZ7E5AFxjtMYY1bfbtonjukK4WnPKUFWLE3CJKReEISzpKShqIf93Qc9BkfMHQmg55lKIC9A1bpyT6sO3s_C-3e2giYsQezhHOIQxDIsDrRvUaGH0cPte5sM09WGJD8GkWO5TsPAwWpfgZ-xntXe_iLxAwzjnK3DmVZ9dcZwr8PbQvjZP5ebl8bm525QBCzaXnujKEOaNYhpLXCPhndDIEG-o9lJ5zo22Wi7NkRZE0spTXnumjTdSY0xW4OaPG5xz3ZTCoNJXd_wJ-QHdXFdQ</recordid><startdate>201212</startdate><enddate>201212</enddate><creator>Khoa Le Dinh</creator><creator>Hayashi, Y.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201212</creationdate><title>Centralized BESS control to minimize demand of PV-supplied micro-grid under voltage constraints</title><author>Khoa Le Dinh ; Hayashi, Y.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-f3b2c35fca5b181907fe7b0c3fc4bf8af66cbdb80010b73842f469f5bcfc8b113</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Batteries</topic><topic>battery energy storage system</topic><topic>compensation</topic><topic>inverter-based</topic><topic>Load flow</topic><topic>Load modeling</topic><topic>PV system</topic><topic>Reactive power</topic><topic>System-on-a-chip</topic><topic>Voltage control</topic><toplevel>online_resources</toplevel><creatorcontrib>Khoa Le Dinh</creatorcontrib><creatorcontrib>Hayashi, Y.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Khoa Le Dinh</au><au>Hayashi, Y.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Centralized BESS control to minimize demand of PV-supplied micro-grid under voltage constraints</atitle><btitle>2012 IEEE International Conference on Power and Energy (PECon)</btitle><stitle>PECon</stitle><date>2012-12</date><risdate>2012</risdate><spage>864</spage><epage>869</epage><pages>864-869</pages><isbn>9781467350174</isbn><isbn>1467350176</isbn><eisbn>1467350184</eisbn><eisbn>9781467350181</eisbn><eisbn>9781467350198</eisbn><eisbn>1467350192</eisbn><abstract>Developments in inverter technology are resulting in distributed generation units built as a combination of a renewable source or energy storage device and an inverter, and such units are increasingly being used in micro-grids. One advantage of this combination is quick power response, allowing for complex control solutions. This paper presents a control method for battery energy storage systems which minimizes power flow from the utility to micro-grids through an interconnection point, and that limits local bus voltages in middle-voltage 6.6 KV micro-grids, such as those supplied by photovoltaic systems and the utility. Micro-grid loop and radial structures are studied to evaluate the effectiveness of the proposed method. MATLAB/Simulink is used to simulate the micro-grid model using actual photovoltaic data and residential loads from Ota City, Japan.</abstract><pub>IEEE</pub><doi>10.1109/PECon.2012.6450297</doi><tpages>6</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 9781467350174
ispartof 2012 IEEE International Conference on Power and Energy (PECon), 2012, p.864-869
issn
language eng
recordid cdi_ieee_primary_6450297
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Batteries
battery energy storage system
compensation
inverter-based
Load flow
Load modeling
PV system
Reactive power
System-on-a-chip
Voltage control
title Centralized BESS control to minimize demand of PV-supplied micro-grid under voltage constraints
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T13%3A44%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Centralized%20BESS%20control%20to%20minimize%20demand%20of%20PV-supplied%20micro-grid%20under%20voltage%20constraints&rft.btitle=2012%20IEEE%20International%20Conference%20on%20Power%20and%20Energy%20(PECon)&rft.au=Khoa%20Le%20Dinh&rft.date=2012-12&rft.spage=864&rft.epage=869&rft.pages=864-869&rft.isbn=9781467350174&rft.isbn_list=1467350176&rft_id=info:doi/10.1109/PECon.2012.6450297&rft_dat=%3Cieee_6IE%3E6450297%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1467350184&rft.eisbn_list=9781467350181&rft.eisbn_list=9781467350198&rft.eisbn_list=1467350192&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6450297&rfr_iscdi=true