Fuzzy logic controller for five-level shunt active power filter under distorted voltage conditions
In this paper, a five-level inverter is used as a shunt active power filter (APF), taking advantages of the multilevel inverter such as low harmonic distortion and reduced switching losses. It is used to compensate reactive power and eliminate harmonics drawn from a diode rectifier feeding a RL load...
Gespeichert in:
Hauptverfasser: | , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 4978 |
---|---|
container_issue | |
container_start_page | 4973 |
container_title | |
container_volume | |
creator | Benaissa, A. Rabhi, B. Benkhoris, M. F. Moussi, A. Le Claire, J. |
description | In this paper, a five-level inverter is used as a shunt active power filter (APF), taking advantages of the multilevel inverter such as low harmonic distortion and reduced switching losses. It is used to compensate reactive power and eliminate harmonics drawn from a diode rectifier feeding a RL load under distorted voltage conditions. The active power filter control strategy is based on the use of self tuning filters (STF) for reference current generation and a fuzzy logic current controller. The use of STF instead of classical extraction filters allows extracting directly the voltage and current fundamental components in the α-β axis without phase locked loop (PLL). This study is divided in two parts. The first one deals with the harmonic isolator which generates the harmonic reference currents. The second part focuses on the generation of the switching pattern of the inverter by using a fuzzy logic controller applied and extended to a five level shunt APF. The MA TLAB Fuzzy Logic Toolbox is used for implementing the fuzzy logic control algorithm. The obtained results show that, the proposed shunt active power filter controller has produced a sinusoidal supply current with low harmonic distortion and in phase with the line voltage. |
doi_str_mv | 10.1109/IECON.2012.6388986 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6388986</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6388986</ieee_id><sourcerecordid>6388986</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-915566a12f0310aba1fe8b9f5d202c65ca445e6ff5ef35ed7dc61741999c66cb3</originalsourceid><addsrcrecordid>eNotUNFKAzEQjKig1v6AvuQHrmaTS-7yKKXVQrEvCr6VXLKpkXgpd2ml_Xqv2IfdYYZh2FlCHoBNAJh-Wsymq7cJZ8AnStS1rtUFuYNSVYKXHMQlGeuqPnPQ-orcgpSikBX_vCHjvv9mjAHwUih2S5r57ng80Jg2wVKb2tylGLGjPg0T9lhE3GOk_deuzdTYPEh0m35PjhDzALvWDduFPqcuo6P7FLPZ4CnLhRxS29-Ta29ij-MzjsjHfPY-fS2Wq5fF9HlZBKhkLvRwpVIGuGcCmGkMeKwb7aXjjFslrSlLicp7iV5IdJWzCqpTQ22Vso0Ykcf_3ICI620Xfkx3WJ9fJP4A2-RaqA</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Fuzzy logic controller for five-level shunt active power filter under distorted voltage conditions</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Benaissa, A. ; Rabhi, B. ; Benkhoris, M. F. ; Moussi, A. ; Le Claire, J.</creator><creatorcontrib>Benaissa, A. ; Rabhi, B. ; Benkhoris, M. F. ; Moussi, A. ; Le Claire, J.</creatorcontrib><description>In this paper, a five-level inverter is used as a shunt active power filter (APF), taking advantages of the multilevel inverter such as low harmonic distortion and reduced switching losses. It is used to compensate reactive power and eliminate harmonics drawn from a diode rectifier feeding a RL load under distorted voltage conditions. The active power filter control strategy is based on the use of self tuning filters (STF) for reference current generation and a fuzzy logic current controller. The use of STF instead of classical extraction filters allows extracting directly the voltage and current fundamental components in the α-β axis without phase locked loop (PLL). This study is divided in two parts. The first one deals with the harmonic isolator which generates the harmonic reference currents. The second part focuses on the generation of the switching pattern of the inverter by using a fuzzy logic controller applied and extended to a five level shunt APF. The MA TLAB Fuzzy Logic Toolbox is used for implementing the fuzzy logic control algorithm. The obtained results show that, the proposed shunt active power filter controller has produced a sinusoidal supply current with low harmonic distortion and in phase with the line voltage.</description><identifier>ISSN: 1553-572X</identifier><identifier>ISBN: 9781467324199</identifier><identifier>ISBN: 1467324191</identifier><identifier>EISBN: 1467324213</identifier><identifier>EISBN: 9781467324205</identifier><identifier>EISBN: 9781467324212</identifier><identifier>EISBN: 1467324205</identifier><identifier>DOI: 10.1109/IECON.2012.6388986</identifier><language>eng</language><publisher>IEEE</publisher><subject>Active filter ; Active filters ; distorted voltage conditions ; fuzzy logic control and PWM control ; Harmonic analysis ; harmonics isolator ; Isolators ; self-tuning filter ; Switches</subject><ispartof>IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society, 2012, p.4973-4978</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6388986$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6388986$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Benaissa, A.</creatorcontrib><creatorcontrib>Rabhi, B.</creatorcontrib><creatorcontrib>Benkhoris, M. F.</creatorcontrib><creatorcontrib>Moussi, A.</creatorcontrib><creatorcontrib>Le Claire, J.</creatorcontrib><title>Fuzzy logic controller for five-level shunt active power filter under distorted voltage conditions</title><title>IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society</title><addtitle>IECON</addtitle><description>In this paper, a five-level inverter is used as a shunt active power filter (APF), taking advantages of the multilevel inverter such as low harmonic distortion and reduced switching losses. It is used to compensate reactive power and eliminate harmonics drawn from a diode rectifier feeding a RL load under distorted voltage conditions. The active power filter control strategy is based on the use of self tuning filters (STF) for reference current generation and a fuzzy logic current controller. The use of STF instead of classical extraction filters allows extracting directly the voltage and current fundamental components in the α-β axis without phase locked loop (PLL). This study is divided in two parts. The first one deals with the harmonic isolator which generates the harmonic reference currents. The second part focuses on the generation of the switching pattern of the inverter by using a fuzzy logic controller applied and extended to a five level shunt APF. The MA TLAB Fuzzy Logic Toolbox is used for implementing the fuzzy logic control algorithm. The obtained results show that, the proposed shunt active power filter controller has produced a sinusoidal supply current with low harmonic distortion and in phase with the line voltage.</description><subject>Active filter</subject><subject>Active filters</subject><subject>distorted voltage conditions</subject><subject>fuzzy logic control and PWM control</subject><subject>Harmonic analysis</subject><subject>harmonics isolator</subject><subject>Isolators</subject><subject>self-tuning filter</subject><subject>Switches</subject><issn>1553-572X</issn><isbn>9781467324199</isbn><isbn>1467324191</isbn><isbn>1467324213</isbn><isbn>9781467324205</isbn><isbn>9781467324212</isbn><isbn>1467324205</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2012</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotUNFKAzEQjKig1v6AvuQHrmaTS-7yKKXVQrEvCr6VXLKpkXgpd2ml_Xqv2IfdYYZh2FlCHoBNAJh-Wsymq7cJZ8AnStS1rtUFuYNSVYKXHMQlGeuqPnPQ-orcgpSikBX_vCHjvv9mjAHwUih2S5r57ng80Jg2wVKb2tylGLGjPg0T9lhE3GOk_deuzdTYPEh0m35PjhDzALvWDduFPqcuo6P7FLPZ4CnLhRxS29-Ta29ij-MzjsjHfPY-fS2Wq5fF9HlZBKhkLvRwpVIGuGcCmGkMeKwb7aXjjFslrSlLicp7iV5IdJWzCqpTQ22Vso0Ykcf_3ICI620Xfkx3WJ9fJP4A2-RaqA</recordid><startdate>201210</startdate><enddate>201210</enddate><creator>Benaissa, A.</creator><creator>Rabhi, B.</creator><creator>Benkhoris, M. F.</creator><creator>Moussi, A.</creator><creator>Le Claire, J.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>201210</creationdate><title>Fuzzy logic controller for five-level shunt active power filter under distorted voltage conditions</title><author>Benaissa, A. ; Rabhi, B. ; Benkhoris, M. F. ; Moussi, A. ; Le Claire, J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-915566a12f0310aba1fe8b9f5d202c65ca445e6ff5ef35ed7dc61741999c66cb3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Active filter</topic><topic>Active filters</topic><topic>distorted voltage conditions</topic><topic>fuzzy logic control and PWM control</topic><topic>Harmonic analysis</topic><topic>harmonics isolator</topic><topic>Isolators</topic><topic>self-tuning filter</topic><topic>Switches</topic><toplevel>online_resources</toplevel><creatorcontrib>Benaissa, A.</creatorcontrib><creatorcontrib>Rabhi, B.</creatorcontrib><creatorcontrib>Benkhoris, M. F.</creatorcontrib><creatorcontrib>Moussi, A.</creatorcontrib><creatorcontrib>Le Claire, J.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Benaissa, A.</au><au>Rabhi, B.</au><au>Benkhoris, M. F.</au><au>Moussi, A.</au><au>Le Claire, J.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Fuzzy logic controller for five-level shunt active power filter under distorted voltage conditions</atitle><btitle>IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society</btitle><stitle>IECON</stitle><date>2012-10</date><risdate>2012</risdate><spage>4973</spage><epage>4978</epage><pages>4973-4978</pages><issn>1553-572X</issn><isbn>9781467324199</isbn><isbn>1467324191</isbn><eisbn>1467324213</eisbn><eisbn>9781467324205</eisbn><eisbn>9781467324212</eisbn><eisbn>1467324205</eisbn><abstract>In this paper, a five-level inverter is used as a shunt active power filter (APF), taking advantages of the multilevel inverter such as low harmonic distortion and reduced switching losses. It is used to compensate reactive power and eliminate harmonics drawn from a diode rectifier feeding a RL load under distorted voltage conditions. The active power filter control strategy is based on the use of self tuning filters (STF) for reference current generation and a fuzzy logic current controller. The use of STF instead of classical extraction filters allows extracting directly the voltage and current fundamental components in the α-β axis without phase locked loop (PLL). This study is divided in two parts. The first one deals with the harmonic isolator which generates the harmonic reference currents. The second part focuses on the generation of the switching pattern of the inverter by using a fuzzy logic controller applied and extended to a five level shunt APF. The MA TLAB Fuzzy Logic Toolbox is used for implementing the fuzzy logic control algorithm. The obtained results show that, the proposed shunt active power filter controller has produced a sinusoidal supply current with low harmonic distortion and in phase with the line voltage.</abstract><pub>IEEE</pub><doi>10.1109/IECON.2012.6388986</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 1553-572X |
ispartof | IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society, 2012, p.4973-4978 |
issn | 1553-572X |
language | eng |
recordid | cdi_ieee_primary_6388986 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Active filter Active filters distorted voltage conditions fuzzy logic control and PWM control Harmonic analysis harmonics isolator Isolators self-tuning filter Switches |
title | Fuzzy logic controller for five-level shunt active power filter under distorted voltage conditions |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T18%3A30%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Fuzzy%20logic%20controller%20for%20five-level%20shunt%20active%20power%20filter%20under%20distorted%20voltage%20conditions&rft.btitle=IECON%202012%20-%2038th%20Annual%20Conference%20on%20IEEE%20Industrial%20Electronics%20Society&rft.au=Benaissa,%20A.&rft.date=2012-10&rft.spage=4973&rft.epage=4978&rft.pages=4973-4978&rft.issn=1553-572X&rft.isbn=9781467324199&rft.isbn_list=1467324191&rft_id=info:doi/10.1109/IECON.2012.6388986&rft_dat=%3Cieee_6IE%3E6388986%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1467324213&rft.eisbn_list=9781467324205&rft.eisbn_list=9781467324212&rft.eisbn_list=1467324205&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6388986&rfr_iscdi=true |