Parameter estimation of dynamic load model using field measurement data performed by OLTC operation

An accurate representation of the dynamic behavior of an electrical load is very important for the analysis of power system operation regarding its stability characteristics, especially for voltage stability analysis. This paper presents the practical experience of dynamic load modeling using the re...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Guo, H., Rudion, K., Abildgaard, H., Komarnicki, P., Styczynski, Z. A.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 7
container_issue
container_start_page 1
container_title
container_volume
creator Guo, H.
Rudion, K.
Abildgaard, H.
Komarnicki, P.
Styczynski, Z. A.
description An accurate representation of the dynamic behavior of an electrical load is very important for the analysis of power system operation regarding its stability characteristics, especially for voltage stability analysis. This paper presents the practical experience of dynamic load modeling using the real system measurement data. In order to capture the dynamic behavior of the power system on a load bus, a perturbation was introduced into the system by adjusting the transformer OLTC (on-load tap changer). That caused voltage changes in the network, and the resultant dynamic system response could be recorded by the power system monitoring devices. Before starting the load modeling process, the measurement data were preprocessed by a proposed DWT-based algorithm (Discrete Wavelet Transformation) to suppress the signal noises of the measurement data and, moreover, to make it more feasible to estimate the load model parameters. By performing the parameter optimization process, the parameters were then identified with the measurement data by NONLSQ technique (non-linear least square).
doi_str_mv 10.1109/PESGM.2012.6345563
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6345563</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6345563</ieee_id><sourcerecordid>6345563</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-7db523dadd1751f37eb6838b3fb2fc2b8d3700c745dbc32f8fd71ef82679e1b33</originalsourceid><addsrcrecordid>eNo1kM1KAzEUhSMq2Na-gG7yAlNzcyeTzFJKrUKlBeu6JJMbicxPyUwXfXsHravDdxYfnMPYA4gFgCifdquP9ftCCpCLAnOlCrxi81IbyAuNUksjr9n0HzTcsAmUKDOlQN-xad9_C6EQcjlh1c4m29BAiVM_xMYOsWt5F7g_t7aJFa8763nTear5qY_tFw-R6rEh258SNdQO3NvB8iOl0KWGPHdnvt3sl7wbq1_dPbsNtu5pfskZ-3xZ7Zev2Wa7fls-b7IIWg2Z9k5J9Nb7ESGgJlcYNA6Dk6GSznjUQlQ6V95VKIMJXgMFIwtdEjjEGXv880YiOhzTuCadD5eD8AfrZVmK</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Parameter estimation of dynamic load model using field measurement data performed by OLTC operation</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Guo, H. ; Rudion, K. ; Abildgaard, H. ; Komarnicki, P. ; Styczynski, Z. A.</creator><creatorcontrib>Guo, H. ; Rudion, K. ; Abildgaard, H. ; Komarnicki, P. ; Styczynski, Z. A.</creatorcontrib><description>An accurate representation of the dynamic behavior of an electrical load is very important for the analysis of power system operation regarding its stability characteristics, especially for voltage stability analysis. This paper presents the practical experience of dynamic load modeling using the real system measurement data. In order to capture the dynamic behavior of the power system on a load bus, a perturbation was introduced into the system by adjusting the transformer OLTC (on-load tap changer). That caused voltage changes in the network, and the resultant dynamic system response could be recorded by the power system monitoring devices. Before starting the load modeling process, the measurement data were preprocessed by a proposed DWT-based algorithm (Discrete Wavelet Transformation) to suppress the signal noises of the measurement data and, moreover, to make it more feasible to estimate the load model parameters. By performing the parameter optimization process, the parameters were then identified with the measurement data by NONLSQ technique (non-linear least square).</description><identifier>ISSN: 1932-5517</identifier><identifier>ISBN: 1467327271</identifier><identifier>ISBN: 9781467327275</identifier><identifier>EISBN: 9781467327282</identifier><identifier>EISBN: 1467327298</identifier><identifier>EISBN: 9781467327299</identifier><identifier>EISBN: 146732728X</identifier><identifier>DOI: 10.1109/PESGM.2012.6345563</identifier><language>eng</language><publisher>IEEE</publisher><subject>Data models ; discrete wavelet transformation ; Load modeling ; Mathematical model ; nonlinear least square optimization ; parameter estimation ; Power measurement ; Power system dynamic load modeling ; Power system dynamics ; Reactive power ; Voltage measurement</subject><ispartof>2012 IEEE Power and Energy Society General Meeting, 2012, p.1-7</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6345563$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2051,27904,54899</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6345563$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Guo, H.</creatorcontrib><creatorcontrib>Rudion, K.</creatorcontrib><creatorcontrib>Abildgaard, H.</creatorcontrib><creatorcontrib>Komarnicki, P.</creatorcontrib><creatorcontrib>Styczynski, Z. A.</creatorcontrib><title>Parameter estimation of dynamic load model using field measurement data performed by OLTC operation</title><title>2012 IEEE Power and Energy Society General Meeting</title><addtitle>PESGM</addtitle><description>An accurate representation of the dynamic behavior of an electrical load is very important for the analysis of power system operation regarding its stability characteristics, especially for voltage stability analysis. This paper presents the practical experience of dynamic load modeling using the real system measurement data. In order to capture the dynamic behavior of the power system on a load bus, a perturbation was introduced into the system by adjusting the transformer OLTC (on-load tap changer). That caused voltage changes in the network, and the resultant dynamic system response could be recorded by the power system monitoring devices. Before starting the load modeling process, the measurement data were preprocessed by a proposed DWT-based algorithm (Discrete Wavelet Transformation) to suppress the signal noises of the measurement data and, moreover, to make it more feasible to estimate the load model parameters. By performing the parameter optimization process, the parameters were then identified with the measurement data by NONLSQ technique (non-linear least square).</description><subject>Data models</subject><subject>discrete wavelet transformation</subject><subject>Load modeling</subject><subject>Mathematical model</subject><subject>nonlinear least square optimization</subject><subject>parameter estimation</subject><subject>Power measurement</subject><subject>Power system dynamic load modeling</subject><subject>Power system dynamics</subject><subject>Reactive power</subject><subject>Voltage measurement</subject><issn>1932-5517</issn><isbn>1467327271</isbn><isbn>9781467327275</isbn><isbn>9781467327282</isbn><isbn>1467327298</isbn><isbn>9781467327299</isbn><isbn>146732728X</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2012</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo1kM1KAzEUhSMq2Na-gG7yAlNzcyeTzFJKrUKlBeu6JJMbicxPyUwXfXsHravDdxYfnMPYA4gFgCifdquP9ftCCpCLAnOlCrxi81IbyAuNUksjr9n0HzTcsAmUKDOlQN-xad9_C6EQcjlh1c4m29BAiVM_xMYOsWt5F7g_t7aJFa8763nTear5qY_tFw-R6rEh258SNdQO3NvB8iOl0KWGPHdnvt3sl7wbq1_dPbsNtu5pfskZ-3xZ7Zev2Wa7fls-b7IIWg2Z9k5J9Nb7ESGgJlcYNA6Dk6GSznjUQlQ6V95VKIMJXgMFIwtdEjjEGXv880YiOhzTuCadD5eD8AfrZVmK</recordid><startdate>201207</startdate><enddate>201207</enddate><creator>Guo, H.</creator><creator>Rudion, K.</creator><creator>Abildgaard, H.</creator><creator>Komarnicki, P.</creator><creator>Styczynski, Z. A.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>201207</creationdate><title>Parameter estimation of dynamic load model using field measurement data performed by OLTC operation</title><author>Guo, H. ; Rudion, K. ; Abildgaard, H. ; Komarnicki, P. ; Styczynski, Z. A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-7db523dadd1751f37eb6838b3fb2fc2b8d3700c745dbc32f8fd71ef82679e1b33</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Data models</topic><topic>discrete wavelet transformation</topic><topic>Load modeling</topic><topic>Mathematical model</topic><topic>nonlinear least square optimization</topic><topic>parameter estimation</topic><topic>Power measurement</topic><topic>Power system dynamic load modeling</topic><topic>Power system dynamics</topic><topic>Reactive power</topic><topic>Voltage measurement</topic><toplevel>online_resources</toplevel><creatorcontrib>Guo, H.</creatorcontrib><creatorcontrib>Rudion, K.</creatorcontrib><creatorcontrib>Abildgaard, H.</creatorcontrib><creatorcontrib>Komarnicki, P.</creatorcontrib><creatorcontrib>Styczynski, Z. A.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE/IET Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Guo, H.</au><au>Rudion, K.</au><au>Abildgaard, H.</au><au>Komarnicki, P.</au><au>Styczynski, Z. A.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Parameter estimation of dynamic load model using field measurement data performed by OLTC operation</atitle><btitle>2012 IEEE Power and Energy Society General Meeting</btitle><stitle>PESGM</stitle><date>2012-07</date><risdate>2012</risdate><spage>1</spage><epage>7</epage><pages>1-7</pages><issn>1932-5517</issn><isbn>1467327271</isbn><isbn>9781467327275</isbn><eisbn>9781467327282</eisbn><eisbn>1467327298</eisbn><eisbn>9781467327299</eisbn><eisbn>146732728X</eisbn><abstract>An accurate representation of the dynamic behavior of an electrical load is very important for the analysis of power system operation regarding its stability characteristics, especially for voltage stability analysis. This paper presents the practical experience of dynamic load modeling using the real system measurement data. In order to capture the dynamic behavior of the power system on a load bus, a perturbation was introduced into the system by adjusting the transformer OLTC (on-load tap changer). That caused voltage changes in the network, and the resultant dynamic system response could be recorded by the power system monitoring devices. Before starting the load modeling process, the measurement data were preprocessed by a proposed DWT-based algorithm (Discrete Wavelet Transformation) to suppress the signal noises of the measurement data and, moreover, to make it more feasible to estimate the load model parameters. By performing the parameter optimization process, the parameters were then identified with the measurement data by NONLSQ technique (non-linear least square).</abstract><pub>IEEE</pub><doi>10.1109/PESGM.2012.6345563</doi><tpages>7</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1932-5517
ispartof 2012 IEEE Power and Energy Society General Meeting, 2012, p.1-7
issn 1932-5517
language eng
recordid cdi_ieee_primary_6345563
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Data models
discrete wavelet transformation
Load modeling
Mathematical model
nonlinear least square optimization
parameter estimation
Power measurement
Power system dynamic load modeling
Power system dynamics
Reactive power
Voltage measurement
title Parameter estimation of dynamic load model using field measurement data performed by OLTC operation
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T19%3A16%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Parameter%20estimation%20of%20dynamic%20load%20model%20using%20field%20measurement%20data%20performed%20by%20OLTC%20operation&rft.btitle=2012%20IEEE%20Power%20and%20Energy%20Society%20General%20Meeting&rft.au=Guo,%20H.&rft.date=2012-07&rft.spage=1&rft.epage=7&rft.pages=1-7&rft.issn=1932-5517&rft.isbn=1467327271&rft.isbn_list=9781467327275&rft_id=info:doi/10.1109/PESGM.2012.6345563&rft_dat=%3Cieee_6IE%3E6345563%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781467327282&rft.eisbn_list=1467327298&rft.eisbn_list=9781467327299&rft.eisbn_list=146732728X&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6345563&rfr_iscdi=true