Cooling efficiency aware workload placement using historical sensor data on IT-facility collaborative control
A priority metric for IT equipment is proposed, and a method for extracting it from historical sensor data is devised. The proposed method consists of classification of cooling efficiency from sampled sensor data and calculation of the priority metric from statistics on these cooling-efficiency clas...
Gespeichert in:
Hauptverfasser: | , , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 6 |
---|---|
container_issue | |
container_start_page | 1 |
container_title | |
container_volume | |
creator | Mase, M. Okitsu, J. Suzuki, E. Nojiri, T. Sano, K. Shimizu, H. |
description | A priority metric for IT equipment is proposed, and a method for extracting it from historical sensor data is devised. The proposed method consists of classification of cooling efficiency from sampled sensor data and calculation of the priority metric from statistics on these cooling-efficiency classes. A proof-of-concept experiment using the priority metric was conducted in a server room with a thermal environment including IT equipment units and cooling facilities. The results of the experiment indicate that IT-workload consolidation based on the proposed metric equalizes variation in server-room temperatures. |
doi_str_mv | 10.1109/IGCC.2012.6322287 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6322287</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6322287</ieee_id><sourcerecordid>6322287</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-4292109bf43ed3df5c4dad8beb5f2dd9d1ef654fdca0c48831e9757d4377dc683</originalsourceid><addsrcrecordid>eNo1kM9KAzEYxCMiqHUfQLzkBbZu_uwme5RFa6HgpZ7Lt8kXjaabkkRL396KdS7DD4aBGUJuWTNnrOnvl4thmPOG8XknOOdanZGqV5rJTgnOWsHPyfU_tP0lqXL-aI7STMtGXpHtEGPw0xtF57zxOJkDhT0kpPuYPkMES3cBDG5xKvQr_ybffS4xeQOBZpxyTNRCARonulzXDowPvhyoiSHAGBMU_41HmkqK4YZcOAgZq5PPyOvT43p4rlcvi-XwsKo9U22pJe_5cdzopEArrGuNtGD1iGPruLW9Zei6VjproDFSa8GwV62yUihlTafFjNz99XpE3OyS30I6bE4PiR9uWVyt</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Cooling efficiency aware workload placement using historical sensor data on IT-facility collaborative control</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Mase, M. ; Okitsu, J. ; Suzuki, E. ; Nojiri, T. ; Sano, K. ; Shimizu, H.</creator><creatorcontrib>Mase, M. ; Okitsu, J. ; Suzuki, E. ; Nojiri, T. ; Sano, K. ; Shimizu, H.</creatorcontrib><description>A priority metric for IT equipment is proposed, and a method for extracting it from historical sensor data is devised. The proposed method consists of classification of cooling efficiency from sampled sensor data and calculation of the priority metric from statistics on these cooling-efficiency classes. A proof-of-concept experiment using the priority metric was conducted in a server room with a thermal environment including IT equipment units and cooling facilities. The results of the experiment indicate that IT-workload consolidation based on the proposed metric equalizes variation in server-room temperatures.</description><identifier>ISBN: 1467321559</identifier><identifier>ISBN: 9781467321556</identifier><identifier>EISBN: 9781467321532</identifier><identifier>EISBN: 1467321540</identifier><identifier>EISBN: 1467321532</identifier><identifier>EISBN: 9781467321549</identifier><identifier>DOI: 10.1109/IGCC.2012.6322287</identifier><language>eng</language><publisher>IEEE</publisher><subject>Cooling ; cooling efficiency ; data center ; energy saving ; Heating ; historical sensor data ; IT-equipment priority ; learning ; Servers ; Temperature distribution ; Temperature measurement ; Temperature sensors</subject><ispartof>2012 International Green Computing Conference (IGCC), 2012, p.1-6</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6322287$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,777,781,786,787,2052,27906,54901</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6322287$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Mase, M.</creatorcontrib><creatorcontrib>Okitsu, J.</creatorcontrib><creatorcontrib>Suzuki, E.</creatorcontrib><creatorcontrib>Nojiri, T.</creatorcontrib><creatorcontrib>Sano, K.</creatorcontrib><creatorcontrib>Shimizu, H.</creatorcontrib><title>Cooling efficiency aware workload placement using historical sensor data on IT-facility collaborative control</title><title>2012 International Green Computing Conference (IGCC)</title><addtitle>IGCC</addtitle><description>A priority metric for IT equipment is proposed, and a method for extracting it from historical sensor data is devised. The proposed method consists of classification of cooling efficiency from sampled sensor data and calculation of the priority metric from statistics on these cooling-efficiency classes. A proof-of-concept experiment using the priority metric was conducted in a server room with a thermal environment including IT equipment units and cooling facilities. The results of the experiment indicate that IT-workload consolidation based on the proposed metric equalizes variation in server-room temperatures.</description><subject>Cooling</subject><subject>cooling efficiency</subject><subject>data center</subject><subject>energy saving</subject><subject>Heating</subject><subject>historical sensor data</subject><subject>IT-equipment priority</subject><subject>learning</subject><subject>Servers</subject><subject>Temperature distribution</subject><subject>Temperature measurement</subject><subject>Temperature sensors</subject><isbn>1467321559</isbn><isbn>9781467321556</isbn><isbn>9781467321532</isbn><isbn>1467321540</isbn><isbn>1467321532</isbn><isbn>9781467321549</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2012</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo1kM9KAzEYxCMiqHUfQLzkBbZu_uwme5RFa6HgpZ7Lt8kXjaabkkRL396KdS7DD4aBGUJuWTNnrOnvl4thmPOG8XknOOdanZGqV5rJTgnOWsHPyfU_tP0lqXL-aI7STMtGXpHtEGPw0xtF57zxOJkDhT0kpPuYPkMES3cBDG5xKvQr_ybffS4xeQOBZpxyTNRCARonulzXDowPvhyoiSHAGBMU_41HmkqK4YZcOAgZq5PPyOvT43p4rlcvi-XwsKo9U22pJe_5cdzopEArrGuNtGD1iGPruLW9Zei6VjproDFSa8GwV62yUihlTafFjNz99XpE3OyS30I6bE4PiR9uWVyt</recordid><startdate>201206</startdate><enddate>201206</enddate><creator>Mase, M.</creator><creator>Okitsu, J.</creator><creator>Suzuki, E.</creator><creator>Nojiri, T.</creator><creator>Sano, K.</creator><creator>Shimizu, H.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201206</creationdate><title>Cooling efficiency aware workload placement using historical sensor data on IT-facility collaborative control</title><author>Mase, M. ; Okitsu, J. ; Suzuki, E. ; Nojiri, T. ; Sano, K. ; Shimizu, H.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-4292109bf43ed3df5c4dad8beb5f2dd9d1ef654fdca0c48831e9757d4377dc683</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Cooling</topic><topic>cooling efficiency</topic><topic>data center</topic><topic>energy saving</topic><topic>Heating</topic><topic>historical sensor data</topic><topic>IT-equipment priority</topic><topic>learning</topic><topic>Servers</topic><topic>Temperature distribution</topic><topic>Temperature measurement</topic><topic>Temperature sensors</topic><toplevel>online_resources</toplevel><creatorcontrib>Mase, M.</creatorcontrib><creatorcontrib>Okitsu, J.</creatorcontrib><creatorcontrib>Suzuki, E.</creatorcontrib><creatorcontrib>Nojiri, T.</creatorcontrib><creatorcontrib>Sano, K.</creatorcontrib><creatorcontrib>Shimizu, H.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Mase, M.</au><au>Okitsu, J.</au><au>Suzuki, E.</au><au>Nojiri, T.</au><au>Sano, K.</au><au>Shimizu, H.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Cooling efficiency aware workload placement using historical sensor data on IT-facility collaborative control</atitle><btitle>2012 International Green Computing Conference (IGCC)</btitle><stitle>IGCC</stitle><date>2012-06</date><risdate>2012</risdate><spage>1</spage><epage>6</epage><pages>1-6</pages><isbn>1467321559</isbn><isbn>9781467321556</isbn><eisbn>9781467321532</eisbn><eisbn>1467321540</eisbn><eisbn>1467321532</eisbn><eisbn>9781467321549</eisbn><abstract>A priority metric for IT equipment is proposed, and a method for extracting it from historical sensor data is devised. The proposed method consists of classification of cooling efficiency from sampled sensor data and calculation of the priority metric from statistics on these cooling-efficiency classes. A proof-of-concept experiment using the priority metric was conducted in a server room with a thermal environment including IT equipment units and cooling facilities. The results of the experiment indicate that IT-workload consolidation based on the proposed metric equalizes variation in server-room temperatures.</abstract><pub>IEEE</pub><doi>10.1109/IGCC.2012.6322287</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISBN: 1467321559 |
ispartof | 2012 International Green Computing Conference (IGCC), 2012, p.1-6 |
issn | |
language | eng |
recordid | cdi_ieee_primary_6322287 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Cooling cooling efficiency data center energy saving Heating historical sensor data IT-equipment priority learning Servers Temperature distribution Temperature measurement Temperature sensors |
title | Cooling efficiency aware workload placement using historical sensor data on IT-facility collaborative control |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T21%3A01%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Cooling%20efficiency%20aware%20workload%20placement%20using%20historical%20sensor%20data%20on%20IT-facility%20collaborative%20control&rft.btitle=2012%20International%20Green%20Computing%20Conference%20(IGCC)&rft.au=Mase,%20M.&rft.date=2012-06&rft.spage=1&rft.epage=6&rft.pages=1-6&rft.isbn=1467321559&rft.isbn_list=9781467321556&rft_id=info:doi/10.1109/IGCC.2012.6322287&rft_dat=%3Cieee_6IE%3E6322287%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781467321532&rft.eisbn_list=1467321540&rft.eisbn_list=1467321532&rft.eisbn_list=9781467321549&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6322287&rfr_iscdi=true |