Research of Main Insulation Structure of Power Transformer Based on 3-D Electric Field
In order to analyze the change law between the maximum electric filed intensity of power transformer and different influential factors, reduce the maximum electric field intensity and manufacturing costs of power transformer, and improve reliability of transformer operation, electric filed distribut...
Gespeichert in:
Hauptverfasser: | , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 4 |
---|---|
container_issue | |
container_start_page | 1 |
container_title | |
container_volume | |
creator | Youhua Gao Shaobo Wang |
description | In order to analyze the change law between the maximum electric filed intensity of power transformer and different influential factors, reduce the maximum electric field intensity and manufacturing costs of power transformer, and improve reliability of transformer operation, electric filed distribution of 110kV power transformer was simulated by using FEM software, main influential factors of electric filed intensity of power transformer were analyzed, variation of maximum electric filed during different factors changing was determined, and the results are discussed, the capacity of different factors influencing on the maximum electric field intensity is obtained, methods of reducing the maximum electric field intensity and manufacturing costs are proposed, theoretical basis has been determined for reducing the maximum electric filed intensity and the manufacturing cost of power transformer. |
doi_str_mv | 10.1109/APPEEC.2012.6307377 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6307377</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6307377</ieee_id><sourcerecordid>6307377</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-9b8aa457ff674a0833fe2d381f370c372a12f3762746ebdfeae19896f4b6ae913</originalsourceid><addsrcrecordid>eNpVUE1Lw0AUXFHBUvMLetk_kLofSd7usdZUCxWLVq_lJXmLK2kiuynivzdiL85lZpjh8RjGZlLMpRT2ZrHdluVyroRU80IL0ABnLLFgZJYDiDwDdf7P5-aCTZTMIc2MtlcsifFDjDBKGysn7O2ZImGo33nv-CP6jq-7eGxx8H3HX4ZwrIdjoN9w239R4LuAXXR9OIz6FiM1fOzp9I6XLdVD8DVfeWqba3bpsI2UnHjKXlflbvmQbp7u18vFJvUS8iG1lUEcP3WugAyF0dqRarSRToOoNSiUapSFgqygqnGEJK2xhcuqAslKPWWzv7ueiPafwR8wfO9Py-gfnmtUdw</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Research of Main Insulation Structure of Power Transformer Based on 3-D Electric Field</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Youhua Gao ; Shaobo Wang</creator><creatorcontrib>Youhua Gao ; Shaobo Wang</creatorcontrib><description>In order to analyze the change law between the maximum electric filed intensity of power transformer and different influential factors, reduce the maximum electric field intensity and manufacturing costs of power transformer, and improve reliability of transformer operation, electric filed distribution of 110kV power transformer was simulated by using FEM software, main influential factors of electric filed intensity of power transformer were analyzed, variation of maximum electric filed during different factors changing was determined, and the results are discussed, the capacity of different factors influencing on the maximum electric field intensity is obtained, methods of reducing the maximum electric field intensity and manufacturing costs are proposed, theoretical basis has been determined for reducing the maximum electric filed intensity and the manufacturing cost of power transformer.</description><identifier>ISSN: 2157-4839</identifier><identifier>ISBN: 9781457705458</identifier><identifier>ISBN: 1457705451</identifier><identifier>EISBN: 9781457705472</identifier><identifier>EISBN: 1457705478</identifier><identifier>EISBN: 145770546X</identifier><identifier>EISBN: 9781457705465</identifier><identifier>DOI: 10.1109/APPEEC.2012.6307377</identifier><language>eng</language><publisher>IEEE</publisher><subject>Electric fields ; Electrostatics ; Insulation ; Low voltage ; Power transformer insulation ; Windings</subject><ispartof>2012 Asia-Pacific Power and Energy Engineering Conference, 2012, p.1-4</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6307377$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6307377$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Youhua Gao</creatorcontrib><creatorcontrib>Shaobo Wang</creatorcontrib><title>Research of Main Insulation Structure of Power Transformer Based on 3-D Electric Field</title><title>2012 Asia-Pacific Power and Energy Engineering Conference</title><addtitle>APPEEC</addtitle><description>In order to analyze the change law between the maximum electric filed intensity of power transformer and different influential factors, reduce the maximum electric field intensity and manufacturing costs of power transformer, and improve reliability of transformer operation, electric filed distribution of 110kV power transformer was simulated by using FEM software, main influential factors of electric filed intensity of power transformer were analyzed, variation of maximum electric filed during different factors changing was determined, and the results are discussed, the capacity of different factors influencing on the maximum electric field intensity is obtained, methods of reducing the maximum electric field intensity and manufacturing costs are proposed, theoretical basis has been determined for reducing the maximum electric filed intensity and the manufacturing cost of power transformer.</description><subject>Electric fields</subject><subject>Electrostatics</subject><subject>Insulation</subject><subject>Low voltage</subject><subject>Power transformer insulation</subject><subject>Windings</subject><issn>2157-4839</issn><isbn>9781457705458</isbn><isbn>1457705451</isbn><isbn>9781457705472</isbn><isbn>1457705478</isbn><isbn>145770546X</isbn><isbn>9781457705465</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2012</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNpVUE1Lw0AUXFHBUvMLetk_kLofSd7usdZUCxWLVq_lJXmLK2kiuynivzdiL85lZpjh8RjGZlLMpRT2ZrHdluVyroRU80IL0ABnLLFgZJYDiDwDdf7P5-aCTZTMIc2MtlcsifFDjDBKGysn7O2ZImGo33nv-CP6jq-7eGxx8H3HX4ZwrIdjoN9w239R4LuAXXR9OIz6FiM1fOzp9I6XLdVD8DVfeWqba3bpsI2UnHjKXlflbvmQbp7u18vFJvUS8iG1lUEcP3WugAyF0dqRarSRToOoNSiUapSFgqygqnGEJK2xhcuqAslKPWWzv7ueiPafwR8wfO9Py-gfnmtUdw</recordid><startdate>201203</startdate><enddate>201203</enddate><creator>Youhua Gao</creator><creator>Shaobo Wang</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201203</creationdate><title>Research of Main Insulation Structure of Power Transformer Based on 3-D Electric Field</title><author>Youhua Gao ; Shaobo Wang</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-9b8aa457ff674a0833fe2d381f370c372a12f3762746ebdfeae19896f4b6ae913</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Electric fields</topic><topic>Electrostatics</topic><topic>Insulation</topic><topic>Low voltage</topic><topic>Power transformer insulation</topic><topic>Windings</topic><toplevel>online_resources</toplevel><creatorcontrib>Youhua Gao</creatorcontrib><creatorcontrib>Shaobo Wang</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Youhua Gao</au><au>Shaobo Wang</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Research of Main Insulation Structure of Power Transformer Based on 3-D Electric Field</atitle><btitle>2012 Asia-Pacific Power and Energy Engineering Conference</btitle><stitle>APPEEC</stitle><date>2012-03</date><risdate>2012</risdate><spage>1</spage><epage>4</epage><pages>1-4</pages><issn>2157-4839</issn><isbn>9781457705458</isbn><isbn>1457705451</isbn><eisbn>9781457705472</eisbn><eisbn>1457705478</eisbn><eisbn>145770546X</eisbn><eisbn>9781457705465</eisbn><abstract>In order to analyze the change law between the maximum electric filed intensity of power transformer and different influential factors, reduce the maximum electric field intensity and manufacturing costs of power transformer, and improve reliability of transformer operation, electric filed distribution of 110kV power transformer was simulated by using FEM software, main influential factors of electric filed intensity of power transformer were analyzed, variation of maximum electric filed during different factors changing was determined, and the results are discussed, the capacity of different factors influencing on the maximum electric field intensity is obtained, methods of reducing the maximum electric field intensity and manufacturing costs are proposed, theoretical basis has been determined for reducing the maximum electric filed intensity and the manufacturing cost of power transformer.</abstract><pub>IEEE</pub><doi>10.1109/APPEEC.2012.6307377</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 2157-4839 |
ispartof | 2012 Asia-Pacific Power and Energy Engineering Conference, 2012, p.1-4 |
issn | 2157-4839 |
language | eng |
recordid | cdi_ieee_primary_6307377 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Electric fields Electrostatics Insulation Low voltage Power transformer insulation Windings |
title | Research of Main Insulation Structure of Power Transformer Based on 3-D Electric Field |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T21%3A04%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Research%20of%20Main%20Insulation%20Structure%20of%20Power%20Transformer%20Based%20on%203-D%20Electric%20Field&rft.btitle=2012%20Asia-Pacific%20Power%20and%20Energy%20Engineering%20Conference&rft.au=Youhua%20Gao&rft.date=2012-03&rft.spage=1&rft.epage=4&rft.pages=1-4&rft.issn=2157-4839&rft.isbn=9781457705458&rft.isbn_list=1457705451&rft_id=info:doi/10.1109/APPEEC.2012.6307377&rft_dat=%3Cieee_6IE%3E6307377%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781457705472&rft.eisbn_list=1457705478&rft.eisbn_list=145770546X&rft.eisbn_list=9781457705465&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6307377&rfr_iscdi=true |