Calibration of wattmeters for standby power testing to IEC 62301
A system for the calibration of wideband wattmeters used in the measurement of standby electrical power in accordance with IEC 62301 has been developed at the National Measurement Institute, Australia (NMIA). The system has been tested with current waveforms having crest factors up to 20 and has unc...
Gespeichert in:
Hauptverfasser: | , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 239 |
---|---|
container_issue | |
container_start_page | 238 |
container_title | |
container_volume | |
creator | Budovsky, I. F. Georgakopoulos, D. |
description | A system for the calibration of wideband wattmeters used in the measurement of standby electrical power in accordance with IEC 62301 has been developed at the National Measurement Institute, Australia (NMIA). The system has been tested with current waveforms having crest factors up to 20 and has uncertainties significantly lower than those required by the standard. |
doi_str_mv | 10.1109/CPEM.2012.6250890 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6250890</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6250890</ieee_id><sourcerecordid>6250890</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-327e428bb61e51e06fb3ef0253cbc506fd47267f54bbfcf0876faca4bd07cffe3</originalsourceid><addsrcrecordid>eNo9kM1Kw0AURsc_MK0-gLiZF0i8d36TnRKqFiq66L7MJHck0iZlZqD07RVaXH0cDpzFx9gDQoUIzVP7tfioBKCojNBQN3DBZqiMlaAU2ktWCDRQAlq8-hey0desAF03Japa37JZSj8AQgHIgj23bjv46PIwjXwK_OBy3lGmmHiYIk_Zjb0_8v10oMgzpTyM3zxPfLlouRES8I7dBLdNdH_eOVu_Ltbte7n6fFu2L6tyaCCXUlhSovbeIGkkMMFLCiC07Hyn_7BXVhgbtPI-dAFqa4LrnPI92C4EknP2eMoORLTZx2Hn4nFzfkH-ArsHTEU</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Calibration of wattmeters for standby power testing to IEC 62301</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Budovsky, I. F. ; Georgakopoulos, D.</creator><creatorcontrib>Budovsky, I. F. ; Georgakopoulos, D.</creatorcontrib><description>A system for the calibration of wideband wattmeters used in the measurement of standby electrical power in accordance with IEC 62301 has been developed at the National Measurement Institute, Australia (NMIA). The system has been tested with current waveforms having crest factors up to 20 and has uncertainties significantly lower than those required by the standard.</description><identifier>ISSN: 0589-1485</identifier><identifier>ISBN: 1467304395</identifier><identifier>ISBN: 9781467304399</identifier><identifier>EISSN: 2160-0171</identifier><identifier>EISBN: 1467304417</identifier><identifier>EISBN: 9781467304412</identifier><identifier>EISBN: 1467304425</identifier><identifier>EISBN: 9781467304429</identifier><identifier>DOI: 10.1109/CPEM.2012.6250890</identifier><language>eng</language><publisher>IEEE</publisher><subject>Calibration ; Current measurement ; Frequency measurement ; IEC standards ; measurement techniques ; measurement uncertainty ; Power measurement ; power standards ; standby power ; Wattmeters ; wideband wattmeters</subject><ispartof>2012 Conference on Precision electromagnetic Measurements, 2012, p.238-239</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6250890$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6250890$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Budovsky, I. F.</creatorcontrib><creatorcontrib>Georgakopoulos, D.</creatorcontrib><title>Calibration of wattmeters for standby power testing to IEC 62301</title><title>2012 Conference on Precision electromagnetic Measurements</title><addtitle>CPEM</addtitle><description>A system for the calibration of wideband wattmeters used in the measurement of standby electrical power in accordance with IEC 62301 has been developed at the National Measurement Institute, Australia (NMIA). The system has been tested with current waveforms having crest factors up to 20 and has uncertainties significantly lower than those required by the standard.</description><subject>Calibration</subject><subject>Current measurement</subject><subject>Frequency measurement</subject><subject>IEC standards</subject><subject>measurement techniques</subject><subject>measurement uncertainty</subject><subject>Power measurement</subject><subject>power standards</subject><subject>standby power</subject><subject>Wattmeters</subject><subject>wideband wattmeters</subject><issn>0589-1485</issn><issn>2160-0171</issn><isbn>1467304395</isbn><isbn>9781467304399</isbn><isbn>1467304417</isbn><isbn>9781467304412</isbn><isbn>1467304425</isbn><isbn>9781467304429</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2012</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo9kM1Kw0AURsc_MK0-gLiZF0i8d36TnRKqFiq66L7MJHck0iZlZqD07RVaXH0cDpzFx9gDQoUIzVP7tfioBKCojNBQN3DBZqiMlaAU2ktWCDRQAlq8-hey0desAF03Japa37JZSj8AQgHIgj23bjv46PIwjXwK_OBy3lGmmHiYIk_Zjb0_8v10oMgzpTyM3zxPfLlouRES8I7dBLdNdH_eOVu_Ltbte7n6fFu2L6tyaCCXUlhSovbeIGkkMMFLCiC07Hyn_7BXVhgbtPI-dAFqa4LrnPI92C4EknP2eMoORLTZx2Hn4nFzfkH-ArsHTEU</recordid><startdate>201207</startdate><enddate>201207</enddate><creator>Budovsky, I. F.</creator><creator>Georgakopoulos, D.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>201207</creationdate><title>Calibration of wattmeters for standby power testing to IEC 62301</title><author>Budovsky, I. F. ; Georgakopoulos, D.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-327e428bb61e51e06fb3ef0253cbc506fd47267f54bbfcf0876faca4bd07cffe3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Calibration</topic><topic>Current measurement</topic><topic>Frequency measurement</topic><topic>IEC standards</topic><topic>measurement techniques</topic><topic>measurement uncertainty</topic><topic>Power measurement</topic><topic>power standards</topic><topic>standby power</topic><topic>Wattmeters</topic><topic>wideband wattmeters</topic><toplevel>online_resources</toplevel><creatorcontrib>Budovsky, I. F.</creatorcontrib><creatorcontrib>Georgakopoulos, D.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Budovsky, I. F.</au><au>Georgakopoulos, D.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Calibration of wattmeters for standby power testing to IEC 62301</atitle><btitle>2012 Conference on Precision electromagnetic Measurements</btitle><stitle>CPEM</stitle><date>2012-07</date><risdate>2012</risdate><spage>238</spage><epage>239</epage><pages>238-239</pages><issn>0589-1485</issn><eissn>2160-0171</eissn><isbn>1467304395</isbn><isbn>9781467304399</isbn><eisbn>1467304417</eisbn><eisbn>9781467304412</eisbn><eisbn>1467304425</eisbn><eisbn>9781467304429</eisbn><abstract>A system for the calibration of wideband wattmeters used in the measurement of standby electrical power in accordance with IEC 62301 has been developed at the National Measurement Institute, Australia (NMIA). The system has been tested with current waveforms having crest factors up to 20 and has uncertainties significantly lower than those required by the standard.</abstract><pub>IEEE</pub><doi>10.1109/CPEM.2012.6250890</doi><tpages>2</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0589-1485 |
ispartof | 2012 Conference on Precision electromagnetic Measurements, 2012, p.238-239 |
issn | 0589-1485 2160-0171 |
language | eng |
recordid | cdi_ieee_primary_6250890 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Calibration Current measurement Frequency measurement IEC standards measurement techniques measurement uncertainty Power measurement power standards standby power Wattmeters wideband wattmeters |
title | Calibration of wattmeters for standby power testing to IEC 62301 |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T06%3A01%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Calibration%20of%20wattmeters%20for%20standby%20power%20testing%20to%20IEC%2062301&rft.btitle=2012%20Conference%20on%20Precision%20electromagnetic%20Measurements&rft.au=Budovsky,%20I.%20F.&rft.date=2012-07&rft.spage=238&rft.epage=239&rft.pages=238-239&rft.issn=0589-1485&rft.eissn=2160-0171&rft.isbn=1467304395&rft.isbn_list=9781467304399&rft_id=info:doi/10.1109/CPEM.2012.6250890&rft_dat=%3Cieee_6IE%3E6250890%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1467304417&rft.eisbn_list=9781467304412&rft.eisbn_list=1467304425&rft.eisbn_list=9781467304429&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6250890&rfr_iscdi=true |