There is a large computational load when measuring the phase difference between two signals of Coriolis mass flowmeter (CMF) because of redundancy calculations, which decreases the accuracy and real time qualities. A novel method for CMF signal processing is proposed based on the revised sliding rec...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Shen Ting'ao, Tu Yaqing, Zhang Haitao
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:There is a large computational load when measuring the phase difference between two signals of Coriolis mass flowmeter (CMF) because of redundancy calculations, which decreases the accuracy and real time qualities. A novel method for CMF signal processing is proposed based on the revised sliding recursive discrete-time Fourier transform (DTFT) algorithm. First, a new adaptive notch filter is introduced to filter the sensor output signals of the CMF and calculate the frequency. Then, a new method based on the revised sliding recursive DTFT algorithm is applied to calculate the real-time phase difference between two enhanced signals. With the frequency and the phase difference obtained, the time interval of the two signals is calculated, and then, the mass flowrate is derived. Simulation and experimental results show that the computational load of the complete set of algorithm is small and numerical overflow never happens along with higher accuracy of the CMF.