Design and analysis of 6 DOF handheld micromanipulator

This paper presents the design and analysis of a handheld manipulator for vitreoretinal microsurgery and other biomedical applications. The design involves a parallel micromanipulator utilizing six piezoelectric linear actuators, combining compactness with a large range of motion and relatively high...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:2012 IEEE International Conference on Robotics and Automation 2012-12, Vol.2012, p.1946-1951
Hauptverfasser: Sungwook Yang, MacLachlan, R. A., Riviere, C. N.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1951
container_issue
container_start_page 1946
container_title 2012 IEEE International Conference on Robotics and Automation
container_volume 2012
creator Sungwook Yang
MacLachlan, R. A.
Riviere, C. N.
description This paper presents the design and analysis of a handheld manipulator for vitreoretinal microsurgery and other biomedical applications. The design involves a parallel micromanipulator utilizing six piezoelectric linear actuators, combining compactness with a large range of motion and relatively high stiffness. Given the available force of the actuators, the overall dimension of the micromanipulator was optimized considering realistic external loads on a remote center of motion representing the point of expected contact with the sclera of the eye during microsurgery. Based on optimization and workspace analysis, a benchtop version of the micromanipulator was built with a base diameter of 25 mm and a height of 50 mm. It provides a hemispherical workspace of 4.0 mm diameter at the tool tip. The manipulation performance of the constructed manipulator was measured under a lateral load applied at the remote center of motion. The micromanipulator tolerated side loads up to 200 mN.
doi_str_mv 10.1109/ICRA.2012.6225133
format Article
fullrecord <record><control><sourceid>pubmed_6IE</sourceid><recordid>TN_cdi_ieee_primary_6225133</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6225133</ieee_id><sourcerecordid>24649394</sourcerecordid><originalsourceid>FETCH-LOGICAL-i362t-bbdf42ebc1436c712d65a263afcb0179c239829d367f9ecedf61e077415c97403</originalsourceid><addsrcrecordid>eNpVUNtqAjEUTG9Ua_2AUij7A2tzzsmemEfR2gqCUFrom2STbE3ZVdnVB__eBW2hD8PAzDAwI8QDyAGANM-z8ftogBJwwIgZEF2IvtFDUKwJlFR8KbqYaZ3Kof66-ueRuRZdkJlMlUbTEXdN8yOlJGK-FR1UrAwZ1RU8CU38Xid27VvY8tDEJtkUCSeTxTRZtfIqlD6poqs3lV3H7b60u019L24KWzahf-ae-Jy-fIzf0vnidTYezdNIjLs0z32hMOQOFLHTgJ4zi0y2cLkEbRySGaLxxLowwQVfMASptYLMGd2u6ImnU-92n1fBL7d1rGx9WP4OaAOPp0AMIfzZ57voCKM2VU4</addsrcrecordid><sourcetype>Index Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Design and analysis of 6 DOF handheld micromanipulator</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Sungwook Yang ; MacLachlan, R. A. ; Riviere, C. N.</creator><creatorcontrib>Sungwook Yang ; MacLachlan, R. A. ; Riviere, C. N.</creatorcontrib><description>This paper presents the design and analysis of a handheld manipulator for vitreoretinal microsurgery and other biomedical applications. The design involves a parallel micromanipulator utilizing six piezoelectric linear actuators, combining compactness with a large range of motion and relatively high stiffness. Given the available force of the actuators, the overall dimension of the micromanipulator was optimized considering realistic external loads on a remote center of motion representing the point of expected contact with the sclera of the eye during microsurgery. Based on optimization and workspace analysis, a benchtop version of the micromanipulator was built with a base diameter of 25 mm and a height of 50 mm. It provides a hemispherical workspace of 4.0 mm diameter at the tool tip. The manipulation performance of the constructed manipulator was measured under a lateral load applied at the remote center of motion. The micromanipulator tolerated side loads up to 200 mN.</description><identifier>ISSN: 1050-4729</identifier><identifier>ISSN: 2152-4092</identifier><identifier>ISBN: 9781467314039</identifier><identifier>ISBN: 146731403X</identifier><identifier>EISSN: 2577-087X</identifier><identifier>EISBN: 9781467314046</identifier><identifier>EISBN: 1467315788</identifier><identifier>EISBN: 1467314056</identifier><identifier>EISBN: 9781467314053</identifier><identifier>EISBN: 9781467315784</identifier><identifier>EISBN: 1467314048</identifier><identifier>DOI: 10.1109/ICRA.2012.6225133</identifier><identifier>PMID: 24649394</identifier><language>eng</language><publisher>United States: IEEE</publisher><subject>Actuators ; Force ; Manganese ; Micromanipulators ; Needles ; Springs</subject><ispartof>2012 IEEE International Conference on Robotics and Automation, 2012-12, Vol.2012, p.1946-1951</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6225133$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,777,781,786,787,2052,27906,54901</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6225133$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24649394$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sungwook Yang</creatorcontrib><creatorcontrib>MacLachlan, R. A.</creatorcontrib><creatorcontrib>Riviere, C. N.</creatorcontrib><title>Design and analysis of 6 DOF handheld micromanipulator</title><title>2012 IEEE International Conference on Robotics and Automation</title><addtitle>ICRA</addtitle><addtitle>IEEE Int Conf Robot Autom</addtitle><description>This paper presents the design and analysis of a handheld manipulator for vitreoretinal microsurgery and other biomedical applications. The design involves a parallel micromanipulator utilizing six piezoelectric linear actuators, combining compactness with a large range of motion and relatively high stiffness. Given the available force of the actuators, the overall dimension of the micromanipulator was optimized considering realistic external loads on a remote center of motion representing the point of expected contact with the sclera of the eye during microsurgery. Based on optimization and workspace analysis, a benchtop version of the micromanipulator was built with a base diameter of 25 mm and a height of 50 mm. It provides a hemispherical workspace of 4.0 mm diameter at the tool tip. The manipulation performance of the constructed manipulator was measured under a lateral load applied at the remote center of motion. The micromanipulator tolerated side loads up to 200 mN.</description><subject>Actuators</subject><subject>Force</subject><subject>Manganese</subject><subject>Micromanipulators</subject><subject>Needles</subject><subject>Springs</subject><issn>1050-4729</issn><issn>2152-4092</issn><issn>2577-087X</issn><isbn>9781467314039</isbn><isbn>146731403X</isbn><isbn>9781467314046</isbn><isbn>1467315788</isbn><isbn>1467314056</isbn><isbn>9781467314053</isbn><isbn>9781467315784</isbn><isbn>1467314048</isbn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNpVUNtqAjEUTG9Ua_2AUij7A2tzzsmemEfR2gqCUFrom2STbE3ZVdnVB__eBW2hD8PAzDAwI8QDyAGANM-z8ftogBJwwIgZEF2IvtFDUKwJlFR8KbqYaZ3Kof66-ueRuRZdkJlMlUbTEXdN8yOlJGK-FR1UrAwZ1RU8CU38Xid27VvY8tDEJtkUCSeTxTRZtfIqlD6poqs3lV3H7b60u019L24KWzahf-ae-Jy-fIzf0vnidTYezdNIjLs0z32hMOQOFLHTgJ4zi0y2cLkEbRySGaLxxLowwQVfMASptYLMGd2u6ImnU-92n1fBL7d1rGx9WP4OaAOPp0AMIfzZ57voCKM2VU4</recordid><startdate>20121231</startdate><enddate>20121231</enddate><creator>Sungwook Yang</creator><creator>MacLachlan, R. A.</creator><creator>Riviere, C. N.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope><scope>NPM</scope></search><sort><creationdate>20121231</creationdate><title>Design and analysis of 6 DOF handheld micromanipulator</title><author>Sungwook Yang ; MacLachlan, R. A. ; Riviere, C. N.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i362t-bbdf42ebc1436c712d65a263afcb0179c239829d367f9ecedf61e077415c97403</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Actuators</topic><topic>Force</topic><topic>Manganese</topic><topic>Micromanipulators</topic><topic>Needles</topic><topic>Springs</topic><toplevel>online_resources</toplevel><creatorcontrib>Sungwook Yang</creatorcontrib><creatorcontrib>MacLachlan, R. A.</creatorcontrib><creatorcontrib>Riviere, C. N.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection><collection>PubMed</collection><jtitle>2012 IEEE International Conference on Robotics and Automation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Sungwook Yang</au><au>MacLachlan, R. A.</au><au>Riviere, C. N.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Design and analysis of 6 DOF handheld micromanipulator</atitle><jtitle>2012 IEEE International Conference on Robotics and Automation</jtitle><stitle>ICRA</stitle><addtitle>IEEE Int Conf Robot Autom</addtitle><date>2012-12-31</date><risdate>2012</risdate><volume>2012</volume><spage>1946</spage><epage>1951</epage><pages>1946-1951</pages><issn>1050-4729</issn><issn>2152-4092</issn><eissn>2577-087X</eissn><isbn>9781467314039</isbn><isbn>146731403X</isbn><eisbn>9781467314046</eisbn><eisbn>1467315788</eisbn><eisbn>1467314056</eisbn><eisbn>9781467314053</eisbn><eisbn>9781467315784</eisbn><eisbn>1467314048</eisbn><abstract>This paper presents the design and analysis of a handheld manipulator for vitreoretinal microsurgery and other biomedical applications. The design involves a parallel micromanipulator utilizing six piezoelectric linear actuators, combining compactness with a large range of motion and relatively high stiffness. Given the available force of the actuators, the overall dimension of the micromanipulator was optimized considering realistic external loads on a remote center of motion representing the point of expected contact with the sclera of the eye during microsurgery. Based on optimization and workspace analysis, a benchtop version of the micromanipulator was built with a base diameter of 25 mm and a height of 50 mm. It provides a hemispherical workspace of 4.0 mm diameter at the tool tip. The manipulation performance of the constructed manipulator was measured under a lateral load applied at the remote center of motion. The micromanipulator tolerated side loads up to 200 mN.</abstract><cop>United States</cop><pub>IEEE</pub><pmid>24649394</pmid><doi>10.1109/ICRA.2012.6225133</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1050-4729
ispartof 2012 IEEE International Conference on Robotics and Automation, 2012-12, Vol.2012, p.1946-1951
issn 1050-4729
2152-4092
2577-087X
language eng
recordid cdi_ieee_primary_6225133
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Actuators
Force
Manganese
Micromanipulators
Needles
Springs
title Design and analysis of 6 DOF handheld micromanipulator
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-21T05%3A35%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Design%20and%20analysis%20of%206%20DOF%20handheld%20micromanipulator&rft.jtitle=2012%20IEEE%20International%20Conference%20on%20Robotics%20and%20Automation&rft.au=Sungwook%20Yang&rft.date=2012-12-31&rft.volume=2012&rft.spage=1946&rft.epage=1951&rft.pages=1946-1951&rft.issn=1050-4729&rft.eissn=2577-087X&rft.isbn=9781467314039&rft.isbn_list=146731403X&rft_id=info:doi/10.1109/ICRA.2012.6225133&rft_dat=%3Cpubmed_6IE%3E24649394%3C/pubmed_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781467314046&rft.eisbn_list=1467315788&rft.eisbn_list=1467314056&rft.eisbn_list=9781467314053&rft.eisbn_list=9781467315784&rft.eisbn_list=1467314048&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/24649394&rft_ieee_id=6225133&rfr_iscdi=true