Effect of increasing the grounding grid resistance of a ground system at a substation on the safety and transient overvoltage on the interior equipments

In substations, protective equipments such as arresters and neutral transformer are being connected to substation ground grid to protect them against transient overvoltage, firing and other damages. But unfortunately, lack of grounding connection of electrical equipments or high resistance of ground...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Bashir, M., Sadeh, J., Kamyab, E., Yaghobi, H.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1027
container_issue
container_start_page 1022
container_title
container_volume
creator Bashir, M.
Sadeh, J.
Kamyab, E.
Yaghobi, H.
description In substations, protective equipments such as arresters and neutral transformer are being connected to substation ground grid to protect them against transient overvoltage, firing and other damages. But unfortunately, lack of grounding connection of electrical equipments or high resistance of grounding grid is one of the main reasons which cause risk for staffs and electrical equipments. In this paper, effect of increasing in grounding grid resistance on transient overvoltage which is caused by short circuit, switching and lightning on the interior equipments and safety in a grounding grid at substation is investigated. Effect of transient overvoltage with different short circuits is another subject that is considered. In this paper, indices for ground grid safety are expressed and grounding grid analysis will be done with CYMGrd software. Transient analysis simulations are carried out using DigSilent software and the results of investigation on a real system are presented.
doi_str_mv 10.1109/EEEIC.2012.6221528
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6221528</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6221528</ieee_id><sourcerecordid>6221528</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-5cf418e5a3afec6d4acd84e5bb131b5dccf831b2e9e5ec4b36f6a0b087ca568c3</originalsourceid><addsrcrecordid>eNo1kMFOwzAMhoMQEjD2AnDJC2wkadOmRzQVmDSJy-6TmzolaE1Hkk7am_C4pKJYluzf_vRbMiGPnK05Z9VzXdfbzVowLtaFEFwKdUWWVal4LsuSK6H4NbmfRcbULVmG8MVSlJIzqe7IT20M6kgHQ63THiFY19H4ibTzw-jaSXXettRjsCGC0zixMK9puISIPYWYRmFsEhHt4GjKySOAwXihkMDowQWLLp06oz8Pxwgd_nPWRfR28BS_R3vqExUeyI2BY8DlXBdk_1rvN--r3cfbdvOyW9mKxZXUJucKJWTpki7aHHSrcpRNwzPeyFZro1IjsEKJOm-ywhTAGqZKDbJQOluQpz9bi4iHk7c9-Mth_mX2C1zJbT8</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Effect of increasing the grounding grid resistance of a ground system at a substation on the safety and transient overvoltage on the interior equipments</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Bashir, M. ; Sadeh, J. ; Kamyab, E. ; Yaghobi, H.</creator><creatorcontrib>Bashir, M. ; Sadeh, J. ; Kamyab, E. ; Yaghobi, H.</creatorcontrib><description>In substations, protective equipments such as arresters and neutral transformer are being connected to substation ground grid to protect them against transient overvoltage, firing and other damages. But unfortunately, lack of grounding connection of electrical equipments or high resistance of grounding grid is one of the main reasons which cause risk for staffs and electrical equipments. In this paper, effect of increasing in grounding grid resistance on transient overvoltage which is caused by short circuit, switching and lightning on the interior equipments and safety in a grounding grid at substation is investigated. Effect of transient overvoltage with different short circuits is another subject that is considered. In this paper, indices for ground grid safety are expressed and grounding grid analysis will be done with CYMGrd software. Transient analysis simulations are carried out using DigSilent software and the results of investigation on a real system are presented.</description><identifier>ISBN: 1457718308</identifier><identifier>ISBN: 9781457718304</identifier><identifier>EISBN: 9781457718281</identifier><identifier>EISBN: 1457718294</identifier><identifier>EISBN: 9781457718298</identifier><identifier>EISBN: 1457718286</identifier><identifier>DOI: 10.1109/EEEIC.2012.6221528</identifier><language>eng</language><publisher>IEEE</publisher><subject>Electric potential ; Grounding ; Grounding Grid ; Grounding Grid Resistance ; Resistance ; Safety ; Soil ; Substations ; Transient analysis ; Transient Overvoltage</subject><ispartof>2012 11th International Conference on Environment and Electrical Engineering, 2012, p.1022-1027</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6221528$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,27902,54895</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6221528$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Bashir, M.</creatorcontrib><creatorcontrib>Sadeh, J.</creatorcontrib><creatorcontrib>Kamyab, E.</creatorcontrib><creatorcontrib>Yaghobi, H.</creatorcontrib><title>Effect of increasing the grounding grid resistance of a ground system at a substation on the safety and transient overvoltage on the interior equipments</title><title>2012 11th International Conference on Environment and Electrical Engineering</title><addtitle>EEEIC</addtitle><description>In substations, protective equipments such as arresters and neutral transformer are being connected to substation ground grid to protect them against transient overvoltage, firing and other damages. But unfortunately, lack of grounding connection of electrical equipments or high resistance of grounding grid is one of the main reasons which cause risk for staffs and electrical equipments. In this paper, effect of increasing in grounding grid resistance on transient overvoltage which is caused by short circuit, switching and lightning on the interior equipments and safety in a grounding grid at substation is investigated. Effect of transient overvoltage with different short circuits is another subject that is considered. In this paper, indices for ground grid safety are expressed and grounding grid analysis will be done with CYMGrd software. Transient analysis simulations are carried out using DigSilent software and the results of investigation on a real system are presented.</description><subject>Electric potential</subject><subject>Grounding</subject><subject>Grounding Grid</subject><subject>Grounding Grid Resistance</subject><subject>Resistance</subject><subject>Safety</subject><subject>Soil</subject><subject>Substations</subject><subject>Transient analysis</subject><subject>Transient Overvoltage</subject><isbn>1457718308</isbn><isbn>9781457718304</isbn><isbn>9781457718281</isbn><isbn>1457718294</isbn><isbn>9781457718298</isbn><isbn>1457718286</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2012</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo1kMFOwzAMhoMQEjD2AnDJC2wkadOmRzQVmDSJy-6TmzolaE1Hkk7am_C4pKJYluzf_vRbMiGPnK05Z9VzXdfbzVowLtaFEFwKdUWWVal4LsuSK6H4NbmfRcbULVmG8MVSlJIzqe7IT20M6kgHQ63THiFY19H4ibTzw-jaSXXettRjsCGC0zixMK9puISIPYWYRmFsEhHt4GjKySOAwXihkMDowQWLLp06oz8Pxwgd_nPWRfR28BS_R3vqExUeyI2BY8DlXBdk_1rvN--r3cfbdvOyW9mKxZXUJucKJWTpki7aHHSrcpRNwzPeyFZro1IjsEKJOm-ywhTAGqZKDbJQOluQpz9bi4iHk7c9-Mth_mX2C1zJbT8</recordid><startdate>201205</startdate><enddate>201205</enddate><creator>Bashir, M.</creator><creator>Sadeh, J.</creator><creator>Kamyab, E.</creator><creator>Yaghobi, H.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201205</creationdate><title>Effect of increasing the grounding grid resistance of a ground system at a substation on the safety and transient overvoltage on the interior equipments</title><author>Bashir, M. ; Sadeh, J. ; Kamyab, E. ; Yaghobi, H.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-5cf418e5a3afec6d4acd84e5bb131b5dccf831b2e9e5ec4b36f6a0b087ca568c3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Electric potential</topic><topic>Grounding</topic><topic>Grounding Grid</topic><topic>Grounding Grid Resistance</topic><topic>Resistance</topic><topic>Safety</topic><topic>Soil</topic><topic>Substations</topic><topic>Transient analysis</topic><topic>Transient Overvoltage</topic><toplevel>online_resources</toplevel><creatorcontrib>Bashir, M.</creatorcontrib><creatorcontrib>Sadeh, J.</creatorcontrib><creatorcontrib>Kamyab, E.</creatorcontrib><creatorcontrib>Yaghobi, H.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Bashir, M.</au><au>Sadeh, J.</au><au>Kamyab, E.</au><au>Yaghobi, H.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Effect of increasing the grounding grid resistance of a ground system at a substation on the safety and transient overvoltage on the interior equipments</atitle><btitle>2012 11th International Conference on Environment and Electrical Engineering</btitle><stitle>EEEIC</stitle><date>2012-05</date><risdate>2012</risdate><spage>1022</spage><epage>1027</epage><pages>1022-1027</pages><isbn>1457718308</isbn><isbn>9781457718304</isbn><eisbn>9781457718281</eisbn><eisbn>1457718294</eisbn><eisbn>9781457718298</eisbn><eisbn>1457718286</eisbn><abstract>In substations, protective equipments such as arresters and neutral transformer are being connected to substation ground grid to protect them against transient overvoltage, firing and other damages. But unfortunately, lack of grounding connection of electrical equipments or high resistance of grounding grid is one of the main reasons which cause risk for staffs and electrical equipments. In this paper, effect of increasing in grounding grid resistance on transient overvoltage which is caused by short circuit, switching and lightning on the interior equipments and safety in a grounding grid at substation is investigated. Effect of transient overvoltage with different short circuits is another subject that is considered. In this paper, indices for ground grid safety are expressed and grounding grid analysis will be done with CYMGrd software. Transient analysis simulations are carried out using DigSilent software and the results of investigation on a real system are presented.</abstract><pub>IEEE</pub><doi>10.1109/EEEIC.2012.6221528</doi><tpages>6</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 1457718308
ispartof 2012 11th International Conference on Environment and Electrical Engineering, 2012, p.1022-1027
issn
language eng
recordid cdi_ieee_primary_6221528
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Electric potential
Grounding
Grounding Grid
Grounding Grid Resistance
Resistance
Safety
Soil
Substations
Transient analysis
Transient Overvoltage
title Effect of increasing the grounding grid resistance of a ground system at a substation on the safety and transient overvoltage on the interior equipments
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T06%3A14%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Effect%20of%20increasing%20the%20grounding%20grid%20resistance%20of%20a%20ground%20system%20at%20a%20substation%20on%20the%20safety%20and%20transient%20overvoltage%20on%20the%20interior%20equipments&rft.btitle=2012%2011th%20International%20Conference%20on%20Environment%20and%20Electrical%20Engineering&rft.au=Bashir,%20M.&rft.date=2012-05&rft.spage=1022&rft.epage=1027&rft.pages=1022-1027&rft.isbn=1457718308&rft.isbn_list=9781457718304&rft_id=info:doi/10.1109/EEEIC.2012.6221528&rft_dat=%3Cieee_6IE%3E6221528%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781457718281&rft.eisbn_list=1457718294&rft.eisbn_list=9781457718298&rft.eisbn_list=1457718286&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6221528&rfr_iscdi=true