A design and application of electric power system time synchronism system based on multi-sources timing

Considering the security, stability and technology trends of current time synchronism system on domestic and international, A Electric Power System Time Synchronism System was designed, which is based on the multi-sources timing synchronization, such as GPS, Bei-dou and IRIG-B sync signal, accord wi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Xu Bao-luo, Zhang Dao-nong, Yuan Wen-guang, Deng Zhi-gang, Liu Tong-jun, Yu Yue-hai
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2282
container_issue
container_start_page 2278
container_title
container_volume 3
creator Xu Bao-luo
Zhang Dao-nong
Yuan Wen-guang
Deng Zhi-gang
Liu Tong-jun
Yu Yue-hai
description Considering the security, stability and technology trends of current time synchronism system on domestic and international, A Electric Power System Time Synchronism System was designed, which is based on the multi-sources timing synchronization, such as GPS, Bei-dou and IRIG-B sync signal, accord with the Electric Power System time synchronization of the technical specification in this paper. And a high-stability crystal oscillator has been introduced to achieve high timekeeping precision in the case of the loss of external time synchronization sources. The time synchronism accuracy of the system is improved up to ±1us and punctual accuracy is better than 1us/min. The system satisfies the technical requirements for electrical power system time synchronization, which has practical application value.
doi_str_mv 10.1109/APAP.2011.6180807
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6180807</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6180807</ieee_id><sourcerecordid>6180807</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-ed7e17a8d52cba84b3e4762146ef235633298e38c24873edfff432ddafed97e93</originalsourceid><addsrcrecordid>eNo1UMtqwzAQVCmFtqk_oPSiH7CrVyzpaEJfEGgOuQdZWrkqtmwshZK_r0uTvczsMjMwi9AjJRWlRD83u2ZXMUJpVVNFFJFX6J4KJoSuGZXXqNBSXXamblGR0jdZRhImpbxDXYMdpNBFbKLDZpr6YE0OY8Sjx9CDzXOweBp_YMbplDIMOIcBFh7t1zzGkIbLvTUJHF6cw7HPoUzjcbaQ_uQhdg_oxps-QXHGFdq_vuw37-X28-1j02zLoEkuwUmg0ii3ZrY1SrQchFyKiBo84-uac6YVcGWZUJKD894LzpwzHpyWoPkKPf3HBgA4THMYzHw6nF_DfwFSo1m5</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>A design and application of electric power system time synchronism system based on multi-sources timing</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Xu Bao-luo ; Zhang Dao-nong ; Yuan Wen-guang ; Deng Zhi-gang ; Liu Tong-jun ; Yu Yue-hai</creator><creatorcontrib>Xu Bao-luo ; Zhang Dao-nong ; Yuan Wen-guang ; Deng Zhi-gang ; Liu Tong-jun ; Yu Yue-hai</creatorcontrib><description>Considering the security, stability and technology trends of current time synchronism system on domestic and international, A Electric Power System Time Synchronism System was designed, which is based on the multi-sources timing synchronization, such as GPS, Bei-dou and IRIG-B sync signal, accord with the Electric Power System time synchronization of the technical specification in this paper. And a high-stability crystal oscillator has been introduced to achieve high timekeeping precision in the case of the loss of external time synchronization sources. The time synchronism accuracy of the system is improved up to ±1us and punctual accuracy is better than 1us/min. The system satisfies the technical requirements for electrical power system time synchronization, which has practical application value.</description><identifier>ISBN: 9781424496228</identifier><identifier>ISBN: 1424496225</identifier><identifier>EISBN: 1424496217</identifier><identifier>EISBN: 9781424496211</identifier><identifier>EISBN: 1424496209</identifier><identifier>EISBN: 9781424496204</identifier><identifier>DOI: 10.1109/APAP.2011.6180807</identifier><language>eng</language><publisher>IEEE</publisher><subject>Bei-dou ; Face ; Global Positioning System ; GPS ; Ice ; Integrated optics ; Lead ; multi-sources timing ; Silicon ; time synchronism system ; Wires</subject><ispartof>2011 International Conference on Advanced Power System Automation and Protection, 2011, Vol.3, p.2278-2282</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6180807$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,27902,54895</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6180807$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Xu Bao-luo</creatorcontrib><creatorcontrib>Zhang Dao-nong</creatorcontrib><creatorcontrib>Yuan Wen-guang</creatorcontrib><creatorcontrib>Deng Zhi-gang</creatorcontrib><creatorcontrib>Liu Tong-jun</creatorcontrib><creatorcontrib>Yu Yue-hai</creatorcontrib><title>A design and application of electric power system time synchronism system based on multi-sources timing</title><title>2011 International Conference on Advanced Power System Automation and Protection</title><addtitle>APAP</addtitle><description>Considering the security, stability and technology trends of current time synchronism system on domestic and international, A Electric Power System Time Synchronism System was designed, which is based on the multi-sources timing synchronization, such as GPS, Bei-dou and IRIG-B sync signal, accord with the Electric Power System time synchronization of the technical specification in this paper. And a high-stability crystal oscillator has been introduced to achieve high timekeeping precision in the case of the loss of external time synchronization sources. The time synchronism accuracy of the system is improved up to ±1us and punctual accuracy is better than 1us/min. The system satisfies the technical requirements for electrical power system time synchronization, which has practical application value.</description><subject>Bei-dou</subject><subject>Face</subject><subject>Global Positioning System</subject><subject>GPS</subject><subject>Ice</subject><subject>Integrated optics</subject><subject>Lead</subject><subject>multi-sources timing</subject><subject>Silicon</subject><subject>time synchronism system</subject><subject>Wires</subject><isbn>9781424496228</isbn><isbn>1424496225</isbn><isbn>1424496217</isbn><isbn>9781424496211</isbn><isbn>1424496209</isbn><isbn>9781424496204</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2011</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo1UMtqwzAQVCmFtqk_oPSiH7CrVyzpaEJfEGgOuQdZWrkqtmwshZK_r0uTvczsMjMwi9AjJRWlRD83u2ZXMUJpVVNFFJFX6J4KJoSuGZXXqNBSXXamblGR0jdZRhImpbxDXYMdpNBFbKLDZpr6YE0OY8Sjx9CDzXOweBp_YMbplDIMOIcBFh7t1zzGkIbLvTUJHF6cw7HPoUzjcbaQ_uQhdg_oxps-QXHGFdq_vuw37-X28-1j02zLoEkuwUmg0ii3ZrY1SrQchFyKiBo84-uac6YVcGWZUJKD894LzpwzHpyWoPkKPf3HBgA4THMYzHw6nF_DfwFSo1m5</recordid><startdate>201110</startdate><enddate>201110</enddate><creator>Xu Bao-luo</creator><creator>Zhang Dao-nong</creator><creator>Yuan Wen-guang</creator><creator>Deng Zhi-gang</creator><creator>Liu Tong-jun</creator><creator>Yu Yue-hai</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201110</creationdate><title>A design and application of electric power system time synchronism system based on multi-sources timing</title><author>Xu Bao-luo ; Zhang Dao-nong ; Yuan Wen-guang ; Deng Zhi-gang ; Liu Tong-jun ; Yu Yue-hai</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-ed7e17a8d52cba84b3e4762146ef235633298e38c24873edfff432ddafed97e93</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Bei-dou</topic><topic>Face</topic><topic>Global Positioning System</topic><topic>GPS</topic><topic>Ice</topic><topic>Integrated optics</topic><topic>Lead</topic><topic>multi-sources timing</topic><topic>Silicon</topic><topic>time synchronism system</topic><topic>Wires</topic><toplevel>online_resources</toplevel><creatorcontrib>Xu Bao-luo</creatorcontrib><creatorcontrib>Zhang Dao-nong</creatorcontrib><creatorcontrib>Yuan Wen-guang</creatorcontrib><creatorcontrib>Deng Zhi-gang</creatorcontrib><creatorcontrib>Liu Tong-jun</creatorcontrib><creatorcontrib>Yu Yue-hai</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Xu Bao-luo</au><au>Zhang Dao-nong</au><au>Yuan Wen-guang</au><au>Deng Zhi-gang</au><au>Liu Tong-jun</au><au>Yu Yue-hai</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>A design and application of electric power system time synchronism system based on multi-sources timing</atitle><btitle>2011 International Conference on Advanced Power System Automation and Protection</btitle><stitle>APAP</stitle><date>2011-10</date><risdate>2011</risdate><volume>3</volume><spage>2278</spage><epage>2282</epage><pages>2278-2282</pages><isbn>9781424496228</isbn><isbn>1424496225</isbn><eisbn>1424496217</eisbn><eisbn>9781424496211</eisbn><eisbn>1424496209</eisbn><eisbn>9781424496204</eisbn><abstract>Considering the security, stability and technology trends of current time synchronism system on domestic and international, A Electric Power System Time Synchronism System was designed, which is based on the multi-sources timing synchronization, such as GPS, Bei-dou and IRIG-B sync signal, accord with the Electric Power System time synchronization of the technical specification in this paper. And a high-stability crystal oscillator has been introduced to achieve high timekeeping precision in the case of the loss of external time synchronization sources. The time synchronism accuracy of the system is improved up to ±1us and punctual accuracy is better than 1us/min. The system satisfies the technical requirements for electrical power system time synchronization, which has practical application value.</abstract><pub>IEEE</pub><doi>10.1109/APAP.2011.6180807</doi><tpages>5</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 9781424496228
ispartof 2011 International Conference on Advanced Power System Automation and Protection, 2011, Vol.3, p.2278-2282
issn
language eng
recordid cdi_ieee_primary_6180807
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Bei-dou
Face
Global Positioning System
GPS
Ice
Integrated optics
Lead
multi-sources timing
Silicon
time synchronism system
Wires
title A design and application of electric power system time synchronism system based on multi-sources timing
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T15%3A23%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=A%20design%20and%20application%20of%20electric%20power%20system%20time%20synchronism%20system%20based%20on%20multi-sources%20timing&rft.btitle=2011%20International%20Conference%20on%20Advanced%20Power%20System%20Automation%20and%20Protection&rft.au=Xu%20Bao-luo&rft.date=2011-10&rft.volume=3&rft.spage=2278&rft.epage=2282&rft.pages=2278-2282&rft.isbn=9781424496228&rft.isbn_list=1424496225&rft_id=info:doi/10.1109/APAP.2011.6180807&rft_dat=%3Cieee_6IE%3E6180807%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1424496217&rft.eisbn_list=9781424496211&rft.eisbn_list=1424496209&rft.eisbn_list=9781424496204&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6180807&rfr_iscdi=true