Multi-source third generation computed tomography for industrial multiphase flows applications

This work describes a multi-source computed tomography. It showed to be a feasible tool to study multiphase systems. In this CT scanner, two different radioactive sources, 192 Ir and 137 Cs, were placed together into a single lead collimated system. The CT is capable to determine and differentiate t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: de Mesquita, C. H., Vasquez, P. A. S., Calvo, W. A. P., Marcato, L. A., Carvalho, D. V. S., Martins, J. F. T., Hamada, M. M.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1302
container_issue
container_start_page 1294
container_title
container_volume
creator de Mesquita, C. H.
Vasquez, P. A. S.
Calvo, W. A. P.
Marcato, L. A.
Carvalho, D. V. S.
Martins, J. F. T.
Hamada, M. M.
description This work describes a multi-source computed tomography. It showed to be a feasible tool to study multiphase systems. In this CT scanner, two different radioactive sources, 192 Ir and 137 Cs, were placed together into a single lead collimated system. The CT is capable to determine and differentiate the attenuation coefficients of materials constituted of three phases (gas, liquid and solid), using two or more different radioisotope energies.
doi_str_mv 10.1109/NSSMIC.2011.6154329
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6154329</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6154329</ieee_id><sourcerecordid>6154329</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-a1ac899bbf6ee1512ff3bdc5aacb9051fac14e5cef96e766de0bfad21ba86a483</originalsourceid><addsrcrecordid>eNo9kMtOwzAURM1LopR-QTf-gRTfJHbiJap4VGphUdhS3TjXrVHSRLYj1L-nQMVsRprRnMUwNgUxAxD67mW9Xi3ms1QAzBTIPEv1GbuBXBWZgFTIczZKZVEkokz1xX8BZXbJRnAMk0zJ_JpNQvgURyml81yO2MdqaKJLQjd4QzzunK_5lvbkMbpuz03X9kOkmseu7bYe-92B285zt6-HEL3Dhrc_gH6Hgbhtuq_Ase8bZ3734ZZdWWwCTU4-Zu-PD2_z52T5-rSY3y8TB4WMCQKaUuuqsooIJKTWZlVtJKKptJBg0UBO0pDVigqlahKVxTqFCkuFeZmN2fSP64ho03vXoj9sTj9l3_sbXLA</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Multi-source third generation computed tomography for industrial multiphase flows applications</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>de Mesquita, C. H. ; Vasquez, P. A. S. ; Calvo, W. A. P. ; Marcato, L. A. ; Carvalho, D. V. S. ; Martins, J. F. T. ; Hamada, M. M.</creator><creatorcontrib>de Mesquita, C. H. ; Vasquez, P. A. S. ; Calvo, W. A. P. ; Marcato, L. A. ; Carvalho, D. V. S. ; Martins, J. F. T. ; Hamada, M. M.</creatorcontrib><description>This work describes a multi-source computed tomography. It showed to be a feasible tool to study multiphase systems. In this CT scanner, two different radioactive sources, 192 Ir and 137 Cs, were placed together into a single lead collimated system. The CT is capable to determine and differentiate the attenuation coefficients of materials constituted of three phases (gas, liquid and solid), using two or more different radioisotope energies.</description><identifier>ISSN: 1082-3654</identifier><identifier>ISBN: 1467301183</identifier><identifier>ISBN: 9781467301183</identifier><identifier>EISSN: 2577-0829</identifier><identifier>EISBN: 1467301205</identifier><identifier>EISBN: 1467301191</identifier><identifier>EISBN: 9781467301206</identifier><identifier>EISBN: 9781467301190</identifier><identifier>DOI: 10.1109/NSSMIC.2011.6154329</identifier><language>eng</language><publisher>IEEE</publisher><subject>Atomic measurements ; Collimators ; Detectors ; Gears ; Steel</subject><ispartof>2011 IEEE Nuclear Science Symposium Conference Record, 2011, p.1294-1302</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6154329$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2051,27904,54898</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6154329$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>de Mesquita, C. H.</creatorcontrib><creatorcontrib>Vasquez, P. A. S.</creatorcontrib><creatorcontrib>Calvo, W. A. P.</creatorcontrib><creatorcontrib>Marcato, L. A.</creatorcontrib><creatorcontrib>Carvalho, D. V. S.</creatorcontrib><creatorcontrib>Martins, J. F. T.</creatorcontrib><creatorcontrib>Hamada, M. M.</creatorcontrib><title>Multi-source third generation computed tomography for industrial multiphase flows applications</title><title>2011 IEEE Nuclear Science Symposium Conference Record</title><addtitle>NSSMIC</addtitle><description>This work describes a multi-source computed tomography. It showed to be a feasible tool to study multiphase systems. In this CT scanner, two different radioactive sources, 192 Ir and 137 Cs, were placed together into a single lead collimated system. The CT is capable to determine and differentiate the attenuation coefficients of materials constituted of three phases (gas, liquid and solid), using two or more different radioisotope energies.</description><subject>Atomic measurements</subject><subject>Collimators</subject><subject>Detectors</subject><subject>Gears</subject><subject>Steel</subject><issn>1082-3654</issn><issn>2577-0829</issn><isbn>1467301183</isbn><isbn>9781467301183</isbn><isbn>1467301205</isbn><isbn>1467301191</isbn><isbn>9781467301206</isbn><isbn>9781467301190</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2011</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo9kMtOwzAURM1LopR-QTf-gRTfJHbiJap4VGphUdhS3TjXrVHSRLYj1L-nQMVsRprRnMUwNgUxAxD67mW9Xi3ms1QAzBTIPEv1GbuBXBWZgFTIczZKZVEkokz1xX8BZXbJRnAMk0zJ_JpNQvgURyml81yO2MdqaKJLQjd4QzzunK_5lvbkMbpuz03X9kOkmseu7bYe-92B285zt6-HEL3Dhrc_gH6Hgbhtuq_Ase8bZ3734ZZdWWwCTU4-Zu-PD2_z52T5-rSY3y8TB4WMCQKaUuuqsooIJKTWZlVtJKKptJBg0UBO0pDVigqlahKVxTqFCkuFeZmN2fSP64ho03vXoj9sTj9l3_sbXLA</recordid><startdate>201110</startdate><enddate>201110</enddate><creator>de Mesquita, C. H.</creator><creator>Vasquez, P. A. S.</creator><creator>Calvo, W. A. P.</creator><creator>Marcato, L. A.</creator><creator>Carvalho, D. V. S.</creator><creator>Martins, J. F. T.</creator><creator>Hamada, M. M.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>201110</creationdate><title>Multi-source third generation computed tomography for industrial multiphase flows applications</title><author>de Mesquita, C. H. ; Vasquez, P. A. S. ; Calvo, W. A. P. ; Marcato, L. A. ; Carvalho, D. V. S. ; Martins, J. F. T. ; Hamada, M. M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-a1ac899bbf6ee1512ff3bdc5aacb9051fac14e5cef96e766de0bfad21ba86a483</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Atomic measurements</topic><topic>Collimators</topic><topic>Detectors</topic><topic>Gears</topic><topic>Steel</topic><toplevel>online_resources</toplevel><creatorcontrib>de Mesquita, C. H.</creatorcontrib><creatorcontrib>Vasquez, P. A. S.</creatorcontrib><creatorcontrib>Calvo, W. A. P.</creatorcontrib><creatorcontrib>Marcato, L. A.</creatorcontrib><creatorcontrib>Carvalho, D. V. S.</creatorcontrib><creatorcontrib>Martins, J. F. T.</creatorcontrib><creatorcontrib>Hamada, M. M.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>de Mesquita, C. H.</au><au>Vasquez, P. A. S.</au><au>Calvo, W. A. P.</au><au>Marcato, L. A.</au><au>Carvalho, D. V. S.</au><au>Martins, J. F. T.</au><au>Hamada, M. M.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Multi-source third generation computed tomography for industrial multiphase flows applications</atitle><btitle>2011 IEEE Nuclear Science Symposium Conference Record</btitle><stitle>NSSMIC</stitle><date>2011-10</date><risdate>2011</risdate><spage>1294</spage><epage>1302</epage><pages>1294-1302</pages><issn>1082-3654</issn><eissn>2577-0829</eissn><isbn>1467301183</isbn><isbn>9781467301183</isbn><eisbn>1467301205</eisbn><eisbn>1467301191</eisbn><eisbn>9781467301206</eisbn><eisbn>9781467301190</eisbn><abstract>This work describes a multi-source computed tomography. It showed to be a feasible tool to study multiphase systems. In this CT scanner, two different radioactive sources, 192 Ir and 137 Cs, were placed together into a single lead collimated system. The CT is capable to determine and differentiate the attenuation coefficients of materials constituted of three phases (gas, liquid and solid), using two or more different radioisotope energies.</abstract><pub>IEEE</pub><doi>10.1109/NSSMIC.2011.6154329</doi><tpages>9</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1082-3654
ispartof 2011 IEEE Nuclear Science Symposium Conference Record, 2011, p.1294-1302
issn 1082-3654
2577-0829
language eng
recordid cdi_ieee_primary_6154329
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Atomic measurements
Collimators
Detectors
Gears
Steel
title Multi-source third generation computed tomography for industrial multiphase flows applications
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T04%3A28%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Multi-source%20third%20generation%20computed%20tomography%20for%20industrial%20multiphase%20flows%20applications&rft.btitle=2011%20IEEE%20Nuclear%20Science%20Symposium%20Conference%20Record&rft.au=de%20Mesquita,%20C.%20H.&rft.date=2011-10&rft.spage=1294&rft.epage=1302&rft.pages=1294-1302&rft.issn=1082-3654&rft.eissn=2577-0829&rft.isbn=1467301183&rft.isbn_list=9781467301183&rft_id=info:doi/10.1109/NSSMIC.2011.6154329&rft_dat=%3Cieee_6IE%3E6154329%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1467301205&rft.eisbn_list=1467301191&rft.eisbn_list=9781467301206&rft.eisbn_list=9781467301190&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6154329&rfr_iscdi=true