Reduction of grid current harmonic injection in cosinusoidal modulated matrix converter controlled induction generator for wind applications part-II

In this paper electric power generation from wind is achieved by directly coupling wind turbine to a squirrel cage induction generator without gear box. A matrix converter (MC) is used as an interface between the grid and the generator for direct to grid power injection. For the control of the induc...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Chatterjee, J. K., Subramanian, S., Meena, V. K.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 5
container_issue
container_start_page 1
container_title
container_volume
creator Chatterjee, J. K.
Subramanian, S.
Meena, V. K.
description In this paper electric power generation from wind is achieved by directly coupling wind turbine to a squirrel cage induction generator without gear box. A matrix converter (MC) is used as an interface between the grid and the generator for direct to grid power injection. For the control of the induction generator voltage and frequency, a cosinusoidal modulation technique for switching of matrix converter devices has been applied. Present work relates to improvement of quality of the grid side current by having a composite structure of multiple matrix converter controlled induction generators in parallel. These aspects enhance the possibility of application of proposed matrix converter control in wind farms having multiple wind turbines.
doi_str_mv 10.1109/INDCON.2011.6139550
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6139550</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6139550</ieee_id><sourcerecordid>6139550</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-329e05d425b4e1c5d5b57b3bae34e420a6dc7324d00d989b69de75d5cd2dbede3</originalsourceid><addsrcrecordid>eNpNkNtqwzAMQD22wUrXL-iLfyCdr3H9OLpboLQwNthbcWy1c0mc4Di7_Mc-eCntYAIhiXOQQAhNKZlRSvRNsbpbrFczRiid5ZRrKckZmmg1p0IqNShzcf5_pkRdoBHjTGZakLcrNOm6PRkizzWjeoR-nsH1Nvkm4GaLd9E7bPsYIST8bmLdBG-xD3s4Kj5g23Q-9F3jnalw3bi-Mgkcrk2K_mug4QNignjoUmyqamA-_J3YQYBoUhPxdsjPAWDTtpW35oA73JqYsqK4RpdbU3UwOdUxen24f1k8Zcv1Y7G4XWaeKpkyzjQQ6QSTpQBqpZOlVCUvDXABghGTO6s4E44Qp-e6zLUDNVjWMVeCAz5G0-NeDwCbNvraxO_N6a_8F-RUbzY</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Reduction of grid current harmonic injection in cosinusoidal modulated matrix converter controlled induction generator for wind applications part-II</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Chatterjee, J. K. ; Subramanian, S. ; Meena, V. K.</creator><creatorcontrib>Chatterjee, J. K. ; Subramanian, S. ; Meena, V. K.</creatorcontrib><description>In this paper electric power generation from wind is achieved by directly coupling wind turbine to a squirrel cage induction generator without gear box. A matrix converter (MC) is used as an interface between the grid and the generator for direct to grid power injection. For the control of the induction generator voltage and frequency, a cosinusoidal modulation technique for switching of matrix converter devices has been applied. Present work relates to improvement of quality of the grid side current by having a composite structure of multiple matrix converter controlled induction generators in parallel. These aspects enhance the possibility of application of proposed matrix converter control in wind farms having multiple wind turbines.</description><identifier>ISSN: 2325-940X</identifier><identifier>ISBN: 9781457711107</identifier><identifier>ISBN: 1457711109</identifier><identifier>EISBN: 9781457711084</identifier><identifier>EISBN: 1457711087</identifier><identifier>EISBN: 1457711095</identifier><identifier>EISBN: 9781457711091</identifier><identifier>DOI: 10.1109/INDCON.2011.6139550</identifier><language>eng</language><publisher>IEEE</publisher><subject>cosinusoidal modulation ; Harmonic analysis ; Harmonic reduction ; Induction generators ; matrix converter ; Matrix converters ; Modulation ; parallel operation ; Power harmonic filters ; power quality ; Stators</subject><ispartof>2011 Annual IEEE India Conference, 2011, p.1-5</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6139550$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6139550$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Chatterjee, J. K.</creatorcontrib><creatorcontrib>Subramanian, S.</creatorcontrib><creatorcontrib>Meena, V. K.</creatorcontrib><title>Reduction of grid current harmonic injection in cosinusoidal modulated matrix converter controlled induction generator for wind applications part-II</title><title>2011 Annual IEEE India Conference</title><addtitle>INDCON</addtitle><description>In this paper electric power generation from wind is achieved by directly coupling wind turbine to a squirrel cage induction generator without gear box. A matrix converter (MC) is used as an interface between the grid and the generator for direct to grid power injection. For the control of the induction generator voltage and frequency, a cosinusoidal modulation technique for switching of matrix converter devices has been applied. Present work relates to improvement of quality of the grid side current by having a composite structure of multiple matrix converter controlled induction generators in parallel. These aspects enhance the possibility of application of proposed matrix converter control in wind farms having multiple wind turbines.</description><subject>cosinusoidal modulation</subject><subject>Harmonic analysis</subject><subject>Harmonic reduction</subject><subject>Induction generators</subject><subject>matrix converter</subject><subject>Matrix converters</subject><subject>Modulation</subject><subject>parallel operation</subject><subject>Power harmonic filters</subject><subject>power quality</subject><subject>Stators</subject><issn>2325-940X</issn><isbn>9781457711107</isbn><isbn>1457711109</isbn><isbn>9781457711084</isbn><isbn>1457711087</isbn><isbn>1457711095</isbn><isbn>9781457711091</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2011</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNpNkNtqwzAMQD22wUrXL-iLfyCdr3H9OLpboLQwNthbcWy1c0mc4Di7_Mc-eCntYAIhiXOQQAhNKZlRSvRNsbpbrFczRiid5ZRrKckZmmg1p0IqNShzcf5_pkRdoBHjTGZakLcrNOm6PRkizzWjeoR-nsH1Nvkm4GaLd9E7bPsYIST8bmLdBG-xD3s4Kj5g23Q-9F3jnalw3bi-Mgkcrk2K_mug4QNignjoUmyqamA-_J3YQYBoUhPxdsjPAWDTtpW35oA73JqYsqK4RpdbU3UwOdUxen24f1k8Zcv1Y7G4XWaeKpkyzjQQ6QSTpQBqpZOlVCUvDXABghGTO6s4E44Qp-e6zLUDNVjWMVeCAz5G0-NeDwCbNvraxO_N6a_8F-RUbzY</recordid><startdate>201112</startdate><enddate>201112</enddate><creator>Chatterjee, J. K.</creator><creator>Subramanian, S.</creator><creator>Meena, V. K.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201112</creationdate><title>Reduction of grid current harmonic injection in cosinusoidal modulated matrix converter controlled induction generator for wind applications part-II</title><author>Chatterjee, J. K. ; Subramanian, S. ; Meena, V. K.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-329e05d425b4e1c5d5b57b3bae34e420a6dc7324d00d989b69de75d5cd2dbede3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2011</creationdate><topic>cosinusoidal modulation</topic><topic>Harmonic analysis</topic><topic>Harmonic reduction</topic><topic>Induction generators</topic><topic>matrix converter</topic><topic>Matrix converters</topic><topic>Modulation</topic><topic>parallel operation</topic><topic>Power harmonic filters</topic><topic>power quality</topic><topic>Stators</topic><toplevel>online_resources</toplevel><creatorcontrib>Chatterjee, J. K.</creatorcontrib><creatorcontrib>Subramanian, S.</creatorcontrib><creatorcontrib>Meena, V. K.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Chatterjee, J. K.</au><au>Subramanian, S.</au><au>Meena, V. K.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Reduction of grid current harmonic injection in cosinusoidal modulated matrix converter controlled induction generator for wind applications part-II</atitle><btitle>2011 Annual IEEE India Conference</btitle><stitle>INDCON</stitle><date>2011-12</date><risdate>2011</risdate><spage>1</spage><epage>5</epage><pages>1-5</pages><issn>2325-940X</issn><isbn>9781457711107</isbn><isbn>1457711109</isbn><eisbn>9781457711084</eisbn><eisbn>1457711087</eisbn><eisbn>1457711095</eisbn><eisbn>9781457711091</eisbn><abstract>In this paper electric power generation from wind is achieved by directly coupling wind turbine to a squirrel cage induction generator without gear box. A matrix converter (MC) is used as an interface between the grid and the generator for direct to grid power injection. For the control of the induction generator voltage and frequency, a cosinusoidal modulation technique for switching of matrix converter devices has been applied. Present work relates to improvement of quality of the grid side current by having a composite structure of multiple matrix converter controlled induction generators in parallel. These aspects enhance the possibility of application of proposed matrix converter control in wind farms having multiple wind turbines.</abstract><pub>IEEE</pub><doi>10.1109/INDCON.2011.6139550</doi><tpages>5</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 2325-940X
ispartof 2011 Annual IEEE India Conference, 2011, p.1-5
issn 2325-940X
language eng
recordid cdi_ieee_primary_6139550
source IEEE Electronic Library (IEL) Conference Proceedings
subjects cosinusoidal modulation
Harmonic analysis
Harmonic reduction
Induction generators
matrix converter
Matrix converters
Modulation
parallel operation
Power harmonic filters
power quality
Stators
title Reduction of grid current harmonic injection in cosinusoidal modulated matrix converter controlled induction generator for wind applications part-II
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T20%3A29%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Reduction%20of%20grid%20current%20harmonic%20injection%20in%20cosinusoidal%20modulated%20matrix%20converter%20controlled%20induction%20generator%20for%20wind%20applications%20part-II&rft.btitle=2011%20Annual%20IEEE%20India%20Conference&rft.au=Chatterjee,%20J.%20K.&rft.date=2011-12&rft.spage=1&rft.epage=5&rft.pages=1-5&rft.issn=2325-940X&rft.isbn=9781457711107&rft.isbn_list=1457711109&rft_id=info:doi/10.1109/INDCON.2011.6139550&rft_dat=%3Cieee_6IE%3E6139550%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781457711084&rft.eisbn_list=1457711087&rft.eisbn_list=1457711095&rft.eisbn_list=9781457711091&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6139550&rfr_iscdi=true