Assessment of the effect of time in the repeatability of the stabilometric parameters in diabetic and non-diabetic subjects during bipedal standing using the LorAn pressure distribution measurement system
This study was designed to assess the effect of time on the repeatability of the LorAn pressure distribution measurement system, and evaluate the variability of plantar pressure and postural balance, during barefoot standing in diabetic and non-diabetic subjects, for future diabetic foot clinical ev...
Gespeichert in:
Hauptverfasser: | , , , , , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 8534 |
---|---|
container_issue | |
container_start_page | 8531 |
container_title | |
container_volume | 2011 |
creator | Zequera, M. L. Garavito, L. Sandham, W. Alvarado, J. A. Rodriguez, A. Wilches, C. A. Villa, A. C. Quintero, S. V. Bernal, J. C. |
description | This study was designed to assess the effect of time on the repeatability of the LorAn pressure distribution measurement system, and evaluate the variability of plantar pressure and postural balance, during barefoot standing in diabetic and non-diabetic subjects, for future diabetic foot clinical evaluation. Fourteen subjects were evaluated (8 females, 6 males, 8 non-diabetics and 6 diabetics, age range 30-70 years) and had no musculoskeletal symptoms. Four variables were measured with the platform in the barefoot standing position. Ten measurements were taken using two different techniques for feet and posture positioning, during three sessions, once a week. The MANOVA test confirmed that the platform measurements are reproducible for variables body baricenter (x) and foot baricenter (x) through time, being the coefficients of variation, with a 99% confidence interval, lower than 1.6% for body baricenter (x), and lower than 2.06% for foot baricenter (x), for all studied conditions. For the remaining variables, the results were not stabilized through time, which makes necessary to standardize the measurement protocol that guarantees the repeatability in all variables. |
doi_str_mv | 10.1109/IEMBS.2011.6092105 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>pubmed_6IE</sourceid><recordid>TN_cdi_ieee_primary_6092105</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6092105</ieee_id><sourcerecordid>22256329</sourcerecordid><originalsourceid>FETCH-LOGICAL-i300t-22ed63414f722d0ee231a5ca5f380c11d5f1ab1572542e1064b9b968bbfaa4593</originalsourceid><addsrcrecordid>eNo9kc1uEzEUhQ0F0VLyAiAhv8AEX_9lvAxVoZVSdQGVuqvs-A64ynhGtmeRd-Sh8CRNvfDPd4_PubIJ-QxsCcDMt9vru--_lpwBLDUzHJh6Qz6C5FJK4Fy_JRegVNtIDeqMLMyqPdUA3tUaM7LR7erxnCxyfmZ1aG2E4B_IOedcacHNBfm3zhlz7jEWOnS0_EWKXYfb4yn0SEM80IQj2mJd2IWyP0nzAQw9lhS2dLTJ1i2mPF_ywTosFdvoaRxi8wry5J5rQqZ-SiH-oS6M6O1udot-BlOe5zlgM6R1pGOqLU4Jq2euSW4qYYi0RzvDQ-t5nwv2n8j7zu4yLl7WS_Lw4_r31U2zuf95e7XeNEEwVhrO0WshQXYrzj1D5AKs2lrViZZtAbzqwDpQK64kR2BaOuOMbp3rrJXKiEvy9eg7Tq5H_zSm0Nu0fzo9axV8OQoCIr6WXz5R_AejLo7z</addsrcrecordid><sourcetype>Index Database</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Assessment of the effect of time in the repeatability of the stabilometric parameters in diabetic and non-diabetic subjects during bipedal standing using the LorAn pressure distribution measurement system</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Zequera, M. L. ; Garavito, L. ; Sandham, W. ; Alvarado, J. A. ; Rodriguez, A. ; Wilches, C. A. ; Villa, A. C. ; Quintero, S. V. ; Bernal, J. C.</creator><creatorcontrib>Zequera, M. L. ; Garavito, L. ; Sandham, W. ; Alvarado, J. A. ; Rodriguez, A. ; Wilches, C. A. ; Villa, A. C. ; Quintero, S. V. ; Bernal, J. C.</creatorcontrib><description>This study was designed to assess the effect of time on the repeatability of the LorAn pressure distribution measurement system, and evaluate the variability of plantar pressure and postural balance, during barefoot standing in diabetic and non-diabetic subjects, for future diabetic foot clinical evaluation. Fourteen subjects were evaluated (8 females, 6 males, 8 non-diabetics and 6 diabetics, age range 30-70 years) and had no musculoskeletal symptoms. Four variables were measured with the platform in the barefoot standing position. Ten measurements were taken using two different techniques for feet and posture positioning, during three sessions, once a week. The MANOVA test confirmed that the platform measurements are reproducible for variables body baricenter (x) and foot baricenter (x) through time, being the coefficients of variation, with a 99% confidence interval, lower than 1.6% for body baricenter (x), and lower than 2.06% for foot baricenter (x), for all studied conditions. For the remaining variables, the results were not stabilized through time, which makes necessary to standardize the measurement protocol that guarantees the repeatability in all variables.</description><identifier>ISSN: 1094-687X</identifier><identifier>ISSN: 1557-170X</identifier><identifier>ISBN: 9781424441211</identifier><identifier>ISBN: 1424441218</identifier><identifier>EISSN: 1558-4615</identifier><identifier>EISBN: 1424441226</identifier><identifier>EISBN: 1457715899</identifier><identifier>EISBN: 9781457715891</identifier><identifier>EISBN: 9781424441228</identifier><identifier>DOI: 10.1109/IEMBS.2011.6092105</identifier><identifier>PMID: 22256329</identifier><language>eng</language><publisher>United States: IEEE</publisher><subject>Adult ; Aged ; Biomechanical Phenomena ; Diabetes ; Diabetes Mellitus - physiopathology ; diabetic foot ; Female ; Foot ; Humans ; Male ; Middle Aged ; Physiology - methods ; plantar pressure ; Position measurement ; postural balance ; Posture - physiology ; Pressure ; Pressure measurement ; Radio navigation ; Reproducibility of Results ; statistical significance ; Three dimensional displays ; Time Factors ; Time measurement ; Weight-Bearing</subject><ispartof>2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2011, Vol.2011, p.8531-8534</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6092105$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6092105$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/22256329$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Zequera, M. L.</creatorcontrib><creatorcontrib>Garavito, L.</creatorcontrib><creatorcontrib>Sandham, W.</creatorcontrib><creatorcontrib>Alvarado, J. A.</creatorcontrib><creatorcontrib>Rodriguez, A.</creatorcontrib><creatorcontrib>Wilches, C. A.</creatorcontrib><creatorcontrib>Villa, A. C.</creatorcontrib><creatorcontrib>Quintero, S. V.</creatorcontrib><creatorcontrib>Bernal, J. C.</creatorcontrib><title>Assessment of the effect of time in the repeatability of the stabilometric parameters in diabetic and non-diabetic subjects during bipedal standing using the LorAn pressure distribution measurement system</title><title>2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society</title><addtitle>IEMBS</addtitle><addtitle>Conf Proc IEEE Eng Med Biol Soc</addtitle><description>This study was designed to assess the effect of time on the repeatability of the LorAn pressure distribution measurement system, and evaluate the variability of plantar pressure and postural balance, during barefoot standing in diabetic and non-diabetic subjects, for future diabetic foot clinical evaluation. Fourteen subjects were evaluated (8 females, 6 males, 8 non-diabetics and 6 diabetics, age range 30-70 years) and had no musculoskeletal symptoms. Four variables were measured with the platform in the barefoot standing position. Ten measurements were taken using two different techniques for feet and posture positioning, during three sessions, once a week. The MANOVA test confirmed that the platform measurements are reproducible for variables body baricenter (x) and foot baricenter (x) through time, being the coefficients of variation, with a 99% confidence interval, lower than 1.6% for body baricenter (x), and lower than 2.06% for foot baricenter (x), for all studied conditions. For the remaining variables, the results were not stabilized through time, which makes necessary to standardize the measurement protocol that guarantees the repeatability in all variables.</description><subject>Adult</subject><subject>Aged</subject><subject>Biomechanical Phenomena</subject><subject>Diabetes</subject><subject>Diabetes Mellitus - physiopathology</subject><subject>diabetic foot</subject><subject>Female</subject><subject>Foot</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Physiology - methods</subject><subject>plantar pressure</subject><subject>Position measurement</subject><subject>postural balance</subject><subject>Posture - physiology</subject><subject>Pressure</subject><subject>Pressure measurement</subject><subject>Radio navigation</subject><subject>Reproducibility of Results</subject><subject>statistical significance</subject><subject>Three dimensional displays</subject><subject>Time Factors</subject><subject>Time measurement</subject><subject>Weight-Bearing</subject><issn>1094-687X</issn><issn>1557-170X</issn><issn>1558-4615</issn><isbn>9781424441211</isbn><isbn>1424441218</isbn><isbn>1424441226</isbn><isbn>1457715899</isbn><isbn>9781457715891</isbn><isbn>9781424441228</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2011</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><sourceid>EIF</sourceid><recordid>eNo9kc1uEzEUhQ0F0VLyAiAhv8AEX_9lvAxVoZVSdQGVuqvs-A64ynhGtmeRd-Sh8CRNvfDPd4_PubIJ-QxsCcDMt9vru--_lpwBLDUzHJh6Qz6C5FJK4Fy_JRegVNtIDeqMLMyqPdUA3tUaM7LR7erxnCxyfmZ1aG2E4B_IOedcacHNBfm3zhlz7jEWOnS0_EWKXYfb4yn0SEM80IQj2mJd2IWyP0nzAQw9lhS2dLTJ1i2mPF_ywTosFdvoaRxi8wry5J5rQqZ-SiH-oS6M6O1udot-BlOe5zlgM6R1pGOqLU4Jq2euSW4qYYi0RzvDQ-t5nwv2n8j7zu4yLl7WS_Lw4_r31U2zuf95e7XeNEEwVhrO0WshQXYrzj1D5AKs2lrViZZtAbzqwDpQK64kR2BaOuOMbp3rrJXKiEvy9eg7Tq5H_zSm0Nu0fzo9axV8OQoCIr6WXz5R_AejLo7z</recordid><startdate>20110101</startdate><enddate>20110101</enddate><creator>Zequera, M. L.</creator><creator>Garavito, L.</creator><creator>Sandham, W.</creator><creator>Alvarado, J. A.</creator><creator>Rodriguez, A.</creator><creator>Wilches, C. A.</creator><creator>Villa, A. C.</creator><creator>Quintero, S. V.</creator><creator>Bernal, J. C.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope></search><sort><creationdate>20110101</creationdate><title>Assessment of the effect of time in the repeatability of the stabilometric parameters in diabetic and non-diabetic subjects during bipedal standing using the LorAn pressure distribution measurement system</title><author>Zequera, M. L. ; Garavito, L. ; Sandham, W. ; Alvarado, J. A. ; Rodriguez, A. ; Wilches, C. A. ; Villa, A. C. ; Quintero, S. V. ; Bernal, J. C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i300t-22ed63414f722d0ee231a5ca5f380c11d5f1ab1572542e1064b9b968bbfaa4593</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Biomechanical Phenomena</topic><topic>Diabetes</topic><topic>Diabetes Mellitus - physiopathology</topic><topic>diabetic foot</topic><topic>Female</topic><topic>Foot</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Physiology - methods</topic><topic>plantar pressure</topic><topic>Position measurement</topic><topic>postural balance</topic><topic>Posture - physiology</topic><topic>Pressure</topic><topic>Pressure measurement</topic><topic>Radio navigation</topic><topic>Reproducibility of Results</topic><topic>statistical significance</topic><topic>Three dimensional displays</topic><topic>Time Factors</topic><topic>Time measurement</topic><topic>Weight-Bearing</topic><toplevel>online_resources</toplevel><creatorcontrib>Zequera, M. L.</creatorcontrib><creatorcontrib>Garavito, L.</creatorcontrib><creatorcontrib>Sandham, W.</creatorcontrib><creatorcontrib>Alvarado, J. A.</creatorcontrib><creatorcontrib>Rodriguez, A.</creatorcontrib><creatorcontrib>Wilches, C. A.</creatorcontrib><creatorcontrib>Villa, A. C.</creatorcontrib><creatorcontrib>Quintero, S. V.</creatorcontrib><creatorcontrib>Bernal, J. C.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE/IET Electronic Library</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Zequera, M. L.</au><au>Garavito, L.</au><au>Sandham, W.</au><au>Alvarado, J. A.</au><au>Rodriguez, A.</au><au>Wilches, C. A.</au><au>Villa, A. C.</au><au>Quintero, S. V.</au><au>Bernal, J. C.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Assessment of the effect of time in the repeatability of the stabilometric parameters in diabetic and non-diabetic subjects during bipedal standing using the LorAn pressure distribution measurement system</atitle><btitle>2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society</btitle><stitle>IEMBS</stitle><addtitle>Conf Proc IEEE Eng Med Biol Soc</addtitle><date>2011-01-01</date><risdate>2011</risdate><volume>2011</volume><spage>8531</spage><epage>8534</epage><pages>8531-8534</pages><issn>1094-687X</issn><issn>1557-170X</issn><eissn>1558-4615</eissn><isbn>9781424441211</isbn><isbn>1424441218</isbn><eisbn>1424441226</eisbn><eisbn>1457715899</eisbn><eisbn>9781457715891</eisbn><eisbn>9781424441228</eisbn><abstract>This study was designed to assess the effect of time on the repeatability of the LorAn pressure distribution measurement system, and evaluate the variability of plantar pressure and postural balance, during barefoot standing in diabetic and non-diabetic subjects, for future diabetic foot clinical evaluation. Fourteen subjects were evaluated (8 females, 6 males, 8 non-diabetics and 6 diabetics, age range 30-70 years) and had no musculoskeletal symptoms. Four variables were measured with the platform in the barefoot standing position. Ten measurements were taken using two different techniques for feet and posture positioning, during three sessions, once a week. The MANOVA test confirmed that the platform measurements are reproducible for variables body baricenter (x) and foot baricenter (x) through time, being the coefficients of variation, with a 99% confidence interval, lower than 1.6% for body baricenter (x), and lower than 2.06% for foot baricenter (x), for all studied conditions. For the remaining variables, the results were not stabilized through time, which makes necessary to standardize the measurement protocol that guarantees the repeatability in all variables.</abstract><cop>United States</cop><pub>IEEE</pub><pmid>22256329</pmid><doi>10.1109/IEMBS.2011.6092105</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 1094-687X |
ispartof | 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2011, Vol.2011, p.8531-8534 |
issn | 1094-687X 1557-170X 1558-4615 |
language | eng |
recordid | cdi_ieee_primary_6092105 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Adult Aged Biomechanical Phenomena Diabetes Diabetes Mellitus - physiopathology diabetic foot Female Foot Humans Male Middle Aged Physiology - methods plantar pressure Position measurement postural balance Posture - physiology Pressure Pressure measurement Radio navigation Reproducibility of Results statistical significance Three dimensional displays Time Factors Time measurement Weight-Bearing |
title | Assessment of the effect of time in the repeatability of the stabilometric parameters in diabetic and non-diabetic subjects during bipedal standing using the LorAn pressure distribution measurement system |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T06%3A06%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Assessment%20of%20the%20effect%20of%20time%20in%20the%20repeatability%20of%20the%20stabilometric%20parameters%20in%20diabetic%20and%20non-diabetic%20subjects%20during%20bipedal%20standing%20using%20the%20LorAn%20pressure%20distribution%20measurement%20system&rft.btitle=2011%20Annual%20International%20Conference%20of%20the%20IEEE%20Engineering%20in%20Medicine%20and%20Biology%20Society&rft.au=Zequera,%20M.%20L.&rft.date=2011-01-01&rft.volume=2011&rft.spage=8531&rft.epage=8534&rft.pages=8531-8534&rft.issn=1094-687X&rft.eissn=1558-4615&rft.isbn=9781424441211&rft.isbn_list=1424441218&rft_id=info:doi/10.1109/IEMBS.2011.6092105&rft_dat=%3Cpubmed_6IE%3E22256329%3C/pubmed_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1424441226&rft.eisbn_list=1457715899&rft.eisbn_list=9781457715891&rft.eisbn_list=9781424441228&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/22256329&rft_ieee_id=6092105&rfr_iscdi=true |