Large artery biomechanical adaptation induced by flow-overload

The present study set out to examine alterations in the biomechanical characteristics of large-artery wall in response to moderate blood flow increase, as such information is scarce in the literature. For this purpose, a shunt was created between the right carotid artery and ipsilateral jugular vein...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Kritharis, E. P., Kakisis, J. D., Stergiopulos, N., Tsangaris, S., Sokolis, D. P.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 4
container_issue
container_start_page 1
container_title
container_volume
creator Kritharis, E. P.
Kakisis, J. D.
Stergiopulos, N.
Tsangaris, S.
Sokolis, D. P.
description The present study set out to examine alterations in the biomechanical characteristics of large-artery wall in response to moderate blood flow increase, as such information is scarce in the literature. For this purpose, a shunt was created between the right carotid artery and ipsilateral jugular vein in a porcine animal model, as a result of which pressure remained unchanged but flow doubled at the proximal arterial segment until animal sacrifice one month later. The shunted and contralateral arterial (proximal) segments were excised for morphological observation, i.e. delineation of the stress-free geometry, and triaxial mechanical testing, i.e. pressurization and longitudinal extension. Blood flow elevation was accompanied by significant lumen enlargement and wall thickening at in-vivo conditions, allowing restoration of shear and intramural-stresses to homeostatic values within one month. The diameter range and shape of the diameter-pressure curves of shunted arteries was also modified, indicating alterations in elastic properties. At mean working pressures, compliance increased and elastic modulus decreased in shunted than contralateral arteries. Our data imply that the arterial morphology under sustained flow-overload adapts within the one-month period of our study, in order to normalize intimal shear and intramural stresses, but this is not the case with the biomechanical characteristics.
doi_str_mv 10.1109/IWBE.2011.6079017
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6079017</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6079017</ieee_id><sourcerecordid>6079017</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-9b38f7893fb7363449e5da32de66dd28530070c2288fb9b35b994d049cc08783</originalsourceid><addsrcrecordid>eNo1kMtKxDAYheMNrGMfQNzkBVL_3JONoMOoAwUXCi6HpEk10mmHtCp9ewccz-YsvsO3OAhdUagoBXuzfrtfVQworRRoC1QfoQsqpNYgpYBjVFApDWGS0xNUWm3-GeenqACghlhmxTkqx_ET9lHKGFAFuq1dfo_Y5SnmGfs0bGPz4frUuA674HaTm9LQ49SHryYG7GfcdsMPGb5j7gYXLtFZ67oxlodeoJeH1evyidTPj-vlXU2ShYlYz02rjeWt11xxIWyUwXEWolIhMCM5gIaGMWNavx9Lb60IIGzTgNGGL9D1nzXFGDe7nLYuz5vDEfwXsPJMXw</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Large artery biomechanical adaptation induced by flow-overload</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Kritharis, E. P. ; Kakisis, J. D. ; Stergiopulos, N. ; Tsangaris, S. ; Sokolis, D. P.</creator><creatorcontrib>Kritharis, E. P. ; Kakisis, J. D. ; Stergiopulos, N. ; Tsangaris, S. ; Sokolis, D. P.</creatorcontrib><description>The present study set out to examine alterations in the biomechanical characteristics of large-artery wall in response to moderate blood flow increase, as such information is scarce in the literature. For this purpose, a shunt was created between the right carotid artery and ipsilateral jugular vein in a porcine animal model, as a result of which pressure remained unchanged but flow doubled at the proximal arterial segment until animal sacrifice one month later. The shunted and contralateral arterial (proximal) segments were excised for morphological observation, i.e. delineation of the stress-free geometry, and triaxial mechanical testing, i.e. pressurization and longitudinal extension. Blood flow elevation was accompanied by significant lumen enlargement and wall thickening at in-vivo conditions, allowing restoration of shear and intramural-stresses to homeostatic values within one month. The diameter range and shape of the diameter-pressure curves of shunted arteries was also modified, indicating alterations in elastic properties. At mean working pressures, compliance increased and elastic modulus decreased in shunted than contralateral arteries. Our data imply that the arterial morphology under sustained flow-overload adapts within the one-month period of our study, in order to normalize intimal shear and intramural stresses, but this is not the case with the biomechanical characteristics.</description><identifier>ISSN: 0018-9294</identifier><identifier>ISBN: 9781457705533</identifier><identifier>ISBN: 1457705532</identifier><identifier>EISSN: 1558-2531</identifier><identifier>EISBN: 1457705540</identifier><identifier>EISBN: 1457705524</identifier><identifier>EISBN: 9781457705540</identifier><identifier>EISBN: 9781457705526</identifier><identifier>DOI: 10.1109/IWBE.2011.6079017</identifier><language>eng</language><publisher>IEEE</publisher><subject>Animals ; Biomechanics ; Carotid arteries ; Hemodynamics ; Stress</subject><ispartof>2011 10th International Workshop on Biomedical Engineering, 2011, p.1-4</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6079017$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2056,27924,54919</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6079017$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Kritharis, E. P.</creatorcontrib><creatorcontrib>Kakisis, J. D.</creatorcontrib><creatorcontrib>Stergiopulos, N.</creatorcontrib><creatorcontrib>Tsangaris, S.</creatorcontrib><creatorcontrib>Sokolis, D. P.</creatorcontrib><title>Large artery biomechanical adaptation induced by flow-overload</title><title>2011 10th International Workshop on Biomedical Engineering</title><addtitle>IWBE</addtitle><description>The present study set out to examine alterations in the biomechanical characteristics of large-artery wall in response to moderate blood flow increase, as such information is scarce in the literature. For this purpose, a shunt was created between the right carotid artery and ipsilateral jugular vein in a porcine animal model, as a result of which pressure remained unchanged but flow doubled at the proximal arterial segment until animal sacrifice one month later. The shunted and contralateral arterial (proximal) segments were excised for morphological observation, i.e. delineation of the stress-free geometry, and triaxial mechanical testing, i.e. pressurization and longitudinal extension. Blood flow elevation was accompanied by significant lumen enlargement and wall thickening at in-vivo conditions, allowing restoration of shear and intramural-stresses to homeostatic values within one month. The diameter range and shape of the diameter-pressure curves of shunted arteries was also modified, indicating alterations in elastic properties. At mean working pressures, compliance increased and elastic modulus decreased in shunted than contralateral arteries. Our data imply that the arterial morphology under sustained flow-overload adapts within the one-month period of our study, in order to normalize intimal shear and intramural stresses, but this is not the case with the biomechanical characteristics.</description><subject>Animals</subject><subject>Biomechanics</subject><subject>Carotid arteries</subject><subject>Hemodynamics</subject><subject>Stress</subject><issn>0018-9294</issn><issn>1558-2531</issn><isbn>9781457705533</isbn><isbn>1457705532</isbn><isbn>1457705540</isbn><isbn>1457705524</isbn><isbn>9781457705540</isbn><isbn>9781457705526</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2011</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo1kMtKxDAYheMNrGMfQNzkBVL_3JONoMOoAwUXCi6HpEk10mmHtCp9ewccz-YsvsO3OAhdUagoBXuzfrtfVQworRRoC1QfoQsqpNYgpYBjVFApDWGS0xNUWm3-GeenqACghlhmxTkqx_ET9lHKGFAFuq1dfo_Y5SnmGfs0bGPz4frUuA674HaTm9LQ49SHryYG7GfcdsMPGb5j7gYXLtFZ67oxlodeoJeH1evyidTPj-vlXU2ShYlYz02rjeWt11xxIWyUwXEWolIhMCM5gIaGMWNavx9Lb60IIGzTgNGGL9D1nzXFGDe7nLYuz5vDEfwXsPJMXw</recordid><startdate>201110</startdate><enddate>201110</enddate><creator>Kritharis, E. P.</creator><creator>Kakisis, J. D.</creator><creator>Stergiopulos, N.</creator><creator>Tsangaris, S.</creator><creator>Sokolis, D. P.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201110</creationdate><title>Large artery biomechanical adaptation induced by flow-overload</title><author>Kritharis, E. P. ; Kakisis, J. D. ; Stergiopulos, N. ; Tsangaris, S. ; Sokolis, D. P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-9b38f7893fb7363449e5da32de66dd28530070c2288fb9b35b994d049cc08783</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Animals</topic><topic>Biomechanics</topic><topic>Carotid arteries</topic><topic>Hemodynamics</topic><topic>Stress</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kritharis, E. P.</creatorcontrib><creatorcontrib>Kakisis, J. D.</creatorcontrib><creatorcontrib>Stergiopulos, N.</creatorcontrib><creatorcontrib>Tsangaris, S.</creatorcontrib><creatorcontrib>Sokolis, D. P.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Kritharis, E. P.</au><au>Kakisis, J. D.</au><au>Stergiopulos, N.</au><au>Tsangaris, S.</au><au>Sokolis, D. P.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Large artery biomechanical adaptation induced by flow-overload</atitle><btitle>2011 10th International Workshop on Biomedical Engineering</btitle><stitle>IWBE</stitle><date>2011-10</date><risdate>2011</risdate><spage>1</spage><epage>4</epage><pages>1-4</pages><issn>0018-9294</issn><eissn>1558-2531</eissn><isbn>9781457705533</isbn><isbn>1457705532</isbn><eisbn>1457705540</eisbn><eisbn>1457705524</eisbn><eisbn>9781457705540</eisbn><eisbn>9781457705526</eisbn><abstract>The present study set out to examine alterations in the biomechanical characteristics of large-artery wall in response to moderate blood flow increase, as such information is scarce in the literature. For this purpose, a shunt was created between the right carotid artery and ipsilateral jugular vein in a porcine animal model, as a result of which pressure remained unchanged but flow doubled at the proximal arterial segment until animal sacrifice one month later. The shunted and contralateral arterial (proximal) segments were excised for morphological observation, i.e. delineation of the stress-free geometry, and triaxial mechanical testing, i.e. pressurization and longitudinal extension. Blood flow elevation was accompanied by significant lumen enlargement and wall thickening at in-vivo conditions, allowing restoration of shear and intramural-stresses to homeostatic values within one month. The diameter range and shape of the diameter-pressure curves of shunted arteries was also modified, indicating alterations in elastic properties. At mean working pressures, compliance increased and elastic modulus decreased in shunted than contralateral arteries. Our data imply that the arterial morphology under sustained flow-overload adapts within the one-month period of our study, in order to normalize intimal shear and intramural stresses, but this is not the case with the biomechanical characteristics.</abstract><pub>IEEE</pub><doi>10.1109/IWBE.2011.6079017</doi><tpages>4</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0018-9294
ispartof 2011 10th International Workshop on Biomedical Engineering, 2011, p.1-4
issn 0018-9294
1558-2531
language eng
recordid cdi_ieee_primary_6079017
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Animals
Biomechanics
Carotid arteries
Hemodynamics
Stress
title Large artery biomechanical adaptation induced by flow-overload
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T07%3A05%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Large%20artery%20biomechanical%20adaptation%20induced%20by%20flow-overload&rft.btitle=2011%2010th%20International%20Workshop%20on%20Biomedical%20Engineering&rft.au=Kritharis,%20E.%20P.&rft.date=2011-10&rft.spage=1&rft.epage=4&rft.pages=1-4&rft.issn=0018-9294&rft.eissn=1558-2531&rft.isbn=9781457705533&rft.isbn_list=1457705532&rft_id=info:doi/10.1109/IWBE.2011.6079017&rft_dat=%3Cieee_6IE%3E6079017%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1457705540&rft.eisbn_list=1457705524&rft.eisbn_list=9781457705540&rft.eisbn_list=9781457705526&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6079017&rfr_iscdi=true