An adaptive protection method for the inverter dominated microgrid

Recently, many technical challenges of the microgrid, such as operation stability, energy management and relay protection, need to be met with the development of the smart gird. Protection is one of the most significant problems. In this paper, the issues related to the protection of microgrid are d...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Ke Dang, Xin He, Daqiang Bi, Cunliang Feng
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 5
container_issue
container_start_page 1
container_title
container_volume
creator Ke Dang
Xin He
Daqiang Bi
Cunliang Feng
description Recently, many technical challenges of the microgrid, such as operation stability, energy management and relay protection, need to be met with the development of the smart gird. Protection is one of the most significant problems. In this paper, the issues related to the protection of microgrid are discussed at first. Thus, after comparing the existing microgrid protection methods, the ideal structure and parameters of the study microgrid are given. Moreover, this paper presents a new protection strategy, which adaptively selects the different fault detection methods in the grid-connected mode and islanded mode of operation. Finally, the selectivity and reliability of the microgrid protection are improved by utilization of this new protection strategy.
doi_str_mv 10.1109/ICEMS.2011.6073457
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6073457</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6073457</ieee_id><sourcerecordid>6073457</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-4fed37b0dbecf9fc2aa242ee67197a7fcc6b23399790bb48eec43d830dc059313</originalsourceid><addsrcrecordid>eNpVj8FOwzAQRI0QEqjkB-DiH0hYx06cPZaqQKUiDvReOfaaGpE4cqxK_D2V6KVzmTeXJw1jDwIqIQCfNqv1-2dVgxBVC1qqRl-xAnUnTqQFKNldX2zV3LJinr_hlLZFgeKOPS9HbpyZcjgSn1LMZHOIIx8oH6LjPiaeD8TDeKSUKXEXhzCaTI4Pwab4lYK7Zzfe_MxUnHvBdi_r3eqt3H68blbLbRkQcqk8Oal7cD1Zj97WxtSqJmq1QG20t7btaykRNULfq47IKuk6Cc5Cg1LIBXv81wYi2k8pDCb97s_H5R-0l00E</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>An adaptive protection method for the inverter dominated microgrid</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Ke Dang ; Xin He ; Daqiang Bi ; Cunliang Feng</creator><creatorcontrib>Ke Dang ; Xin He ; Daqiang Bi ; Cunliang Feng</creatorcontrib><description>Recently, many technical challenges of the microgrid, such as operation stability, energy management and relay protection, need to be met with the development of the smart gird. Protection is one of the most significant problems. In this paper, the issues related to the protection of microgrid are discussed at first. Thus, after comparing the existing microgrid protection methods, the ideal structure and parameters of the study microgrid are given. Moreover, this paper presents a new protection strategy, which adaptively selects the different fault detection methods in the grid-connected mode and islanded mode of operation. Finally, the selectivity and reliability of the microgrid protection are improved by utilization of this new protection strategy.</description><identifier>ISBN: 9781457710445</identifier><identifier>ISBN: 1457710447</identifier><identifier>EISBN: 9781457710438</identifier><identifier>EISBN: 1457710439</identifier><identifier>EISBN: 1457710420</identifier><identifier>EISBN: 9781457710421</identifier><identifier>DOI: 10.1109/ICEMS.2011.6073457</identifier><language>eng</language><publisher>IEEE</publisher><subject>Earth ; Fault currents ; Generators ; Grounding ; Impedance ; Power transformers ; Relays</subject><ispartof>2011 International Conference on Electrical Machines and Systems, 2011, p.1-5</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6073457$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6073457$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Ke Dang</creatorcontrib><creatorcontrib>Xin He</creatorcontrib><creatorcontrib>Daqiang Bi</creatorcontrib><creatorcontrib>Cunliang Feng</creatorcontrib><title>An adaptive protection method for the inverter dominated microgrid</title><title>2011 International Conference on Electrical Machines and Systems</title><addtitle>ICEMS</addtitle><description>Recently, many technical challenges of the microgrid, such as operation stability, energy management and relay protection, need to be met with the development of the smart gird. Protection is one of the most significant problems. In this paper, the issues related to the protection of microgrid are discussed at first. Thus, after comparing the existing microgrid protection methods, the ideal structure and parameters of the study microgrid are given. Moreover, this paper presents a new protection strategy, which adaptively selects the different fault detection methods in the grid-connected mode and islanded mode of operation. Finally, the selectivity and reliability of the microgrid protection are improved by utilization of this new protection strategy.</description><subject>Earth</subject><subject>Fault currents</subject><subject>Generators</subject><subject>Grounding</subject><subject>Impedance</subject><subject>Power transformers</subject><subject>Relays</subject><isbn>9781457710445</isbn><isbn>1457710447</isbn><isbn>9781457710438</isbn><isbn>1457710439</isbn><isbn>1457710420</isbn><isbn>9781457710421</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2011</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNpVj8FOwzAQRI0QEqjkB-DiH0hYx06cPZaqQKUiDvReOfaaGpE4cqxK_D2V6KVzmTeXJw1jDwIqIQCfNqv1-2dVgxBVC1qqRl-xAnUnTqQFKNldX2zV3LJinr_hlLZFgeKOPS9HbpyZcjgSn1LMZHOIIx8oH6LjPiaeD8TDeKSUKXEXhzCaTI4Pwab4lYK7Zzfe_MxUnHvBdi_r3eqt3H68blbLbRkQcqk8Oal7cD1Zj97WxtSqJmq1QG20t7btaykRNULfq47IKuk6Cc5Cg1LIBXv81wYi2k8pDCb97s_H5R-0l00E</recordid><startdate>201108</startdate><enddate>201108</enddate><creator>Ke Dang</creator><creator>Xin He</creator><creator>Daqiang Bi</creator><creator>Cunliang Feng</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201108</creationdate><title>An adaptive protection method for the inverter dominated microgrid</title><author>Ke Dang ; Xin He ; Daqiang Bi ; Cunliang Feng</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-4fed37b0dbecf9fc2aa242ee67197a7fcc6b23399790bb48eec43d830dc059313</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Earth</topic><topic>Fault currents</topic><topic>Generators</topic><topic>Grounding</topic><topic>Impedance</topic><topic>Power transformers</topic><topic>Relays</topic><toplevel>online_resources</toplevel><creatorcontrib>Ke Dang</creatorcontrib><creatorcontrib>Xin He</creatorcontrib><creatorcontrib>Daqiang Bi</creatorcontrib><creatorcontrib>Cunliang Feng</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Ke Dang</au><au>Xin He</au><au>Daqiang Bi</au><au>Cunliang Feng</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>An adaptive protection method for the inverter dominated microgrid</atitle><btitle>2011 International Conference on Electrical Machines and Systems</btitle><stitle>ICEMS</stitle><date>2011-08</date><risdate>2011</risdate><spage>1</spage><epage>5</epage><pages>1-5</pages><isbn>9781457710445</isbn><isbn>1457710447</isbn><eisbn>9781457710438</eisbn><eisbn>1457710439</eisbn><eisbn>1457710420</eisbn><eisbn>9781457710421</eisbn><abstract>Recently, many technical challenges of the microgrid, such as operation stability, energy management and relay protection, need to be met with the development of the smart gird. Protection is one of the most significant problems. In this paper, the issues related to the protection of microgrid are discussed at first. Thus, after comparing the existing microgrid protection methods, the ideal structure and parameters of the study microgrid are given. Moreover, this paper presents a new protection strategy, which adaptively selects the different fault detection methods in the grid-connected mode and islanded mode of operation. Finally, the selectivity and reliability of the microgrid protection are improved by utilization of this new protection strategy.</abstract><pub>IEEE</pub><doi>10.1109/ICEMS.2011.6073457</doi><tpages>5</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 9781457710445
ispartof 2011 International Conference on Electrical Machines and Systems, 2011, p.1-5
issn
language eng
recordid cdi_ieee_primary_6073457
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Earth
Fault currents
Generators
Grounding
Impedance
Power transformers
Relays
title An adaptive protection method for the inverter dominated microgrid
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T16%3A49%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=An%20adaptive%20protection%20method%20for%20the%20inverter%20dominated%20microgrid&rft.btitle=2011%20International%20Conference%20on%20Electrical%20Machines%20and%20Systems&rft.au=Ke%20Dang&rft.date=2011-08&rft.spage=1&rft.epage=5&rft.pages=1-5&rft.isbn=9781457710445&rft.isbn_list=1457710447&rft_id=info:doi/10.1109/ICEMS.2011.6073457&rft_dat=%3Cieee_6IE%3E6073457%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781457710438&rft.eisbn_list=1457710439&rft.eisbn_list=1457710420&rft.eisbn_list=9781457710421&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6073457&rfr_iscdi=true