Lightning, grounding, and protection for control and communications systems: Re-evaluated

Protection for installations that have been modernized or retrofitted presents a unique mix of problems that require a different perspective from a new installation. The paper addresses lightning, transients, and radiation that causes problems on programmable logic controllers, distributed control s...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Durham, R. A., Durham, M. O.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 11
container_issue
container_start_page 1
container_title
container_volume
creator Durham, R. A.
Durham, M. O.
description Protection for installations that have been modernized or retrofitted presents a unique mix of problems that require a different perspective from a new installation. The paper addresses lightning, transients, and radiation that causes problems on programmable logic controllers, distributed control systems, and remote electronic transducers. While complex grounding grids and networks were not often required for analog systems, digital equipment requires a more effective means of maintaining equal potential throughout the facility. Methods of protecting circuits include a variety of sophisticated and not so elegant techniques. Special consideration must be given to the impact that towers have on a protection system. The investigation ranges from no air terminals to lightning arrays. The protection problem is compounded when different soils such as clay and rock are encountered. Methods of calculating the grounding circuit resistance are identified. Although the paper is based on a retrofit to a pipeline station, the techniques are appropriate for any industrial installation using distributed control.
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_5936962</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5936962</ieee_id><sourcerecordid>5936962</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-9d2ff7877b58525fbca307ec4282f60bebd23e8e3f77bdfed92c1a329443b5f93</originalsourceid><addsrcrecordid>eNotjMtKAzEYhQMqWOo8gZt5AAdymdzcSfEGA4J046pkkj9jpJOUJCP07a3Vs_kOfIdzgRotFem5lBhTIi_RihJOOikEv0ZNKV_4FIFVj8kKfQxh-qwxxOmunXJaojtXE117yKmCrSHF1qfc2hRrTvuzsmmelxis-bWlLcdSYS737Tt08G32i6ngbtCVN_sCzT_XaPv0uN28dMPb8-vmYeiCxrXTjnovlZQjV5xyP1rDsATbU0W9wCOMjjJQwPxp4jw4TS0xjOq-ZyP3mq3R7d9tAIDdIYfZ5OOOaya0oOwHvgJO8w</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Lightning, grounding, and protection for control and communications systems: Re-evaluated</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Durham, R. A. ; Durham, M. O.</creator><creatorcontrib>Durham, R. A. ; Durham, M. O.</creatorcontrib><description>Protection for installations that have been modernized or retrofitted presents a unique mix of problems that require a different perspective from a new installation. The paper addresses lightning, transients, and radiation that causes problems on programmable logic controllers, distributed control systems, and remote electronic transducers. While complex grounding grids and networks were not often required for analog systems, digital equipment requires a more effective means of maintaining equal potential throughout the facility. Methods of protecting circuits include a variety of sophisticated and not so elegant techniques. Special consideration must be given to the impact that towers have on a protection system. The investigation ranges from no air terminals to lightning arrays. The protection problem is compounded when different soils such as clay and rock are encountered. Methods of calculating the grounding circuit resistance are identified. Although the paper is based on a retrofit to a pipeline station, the techniques are appropriate for any industrial installation using distributed control.</description><identifier>ISSN: 2151-7665</identifier><identifier>ISBN: 9781457700217</identifier><identifier>ISBN: 1457700212</identifier><language>eng</language><publisher>IEEE</publisher><subject>Air Terminals ; Conductivity ; Electric potential ; Electrodes ; Ground Radials ; Ground Ring ; Grounding ; Lightning ; Lightning Protection ; Poles and towers ; Soil</subject><ispartof>Petroleum and Chemical Industry Conference Europe Electrical and Instrumentation Applications, 2011, p.1-11</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5936962$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5936962$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Durham, R. A.</creatorcontrib><creatorcontrib>Durham, M. O.</creatorcontrib><title>Lightning, grounding, and protection for control and communications systems: Re-evaluated</title><title>Petroleum and Chemical Industry Conference Europe Electrical and Instrumentation Applications</title><addtitle>PCICEUROPE</addtitle><description>Protection for installations that have been modernized or retrofitted presents a unique mix of problems that require a different perspective from a new installation. The paper addresses lightning, transients, and radiation that causes problems on programmable logic controllers, distributed control systems, and remote electronic transducers. While complex grounding grids and networks were not often required for analog systems, digital equipment requires a more effective means of maintaining equal potential throughout the facility. Methods of protecting circuits include a variety of sophisticated and not so elegant techniques. Special consideration must be given to the impact that towers have on a protection system. The investigation ranges from no air terminals to lightning arrays. The protection problem is compounded when different soils such as clay and rock are encountered. Methods of calculating the grounding circuit resistance are identified. Although the paper is based on a retrofit to a pipeline station, the techniques are appropriate for any industrial installation using distributed control.</description><subject>Air Terminals</subject><subject>Conductivity</subject><subject>Electric potential</subject><subject>Electrodes</subject><subject>Ground Radials</subject><subject>Ground Ring</subject><subject>Grounding</subject><subject>Lightning</subject><subject>Lightning Protection</subject><subject>Poles and towers</subject><subject>Soil</subject><issn>2151-7665</issn><isbn>9781457700217</isbn><isbn>1457700212</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2011</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotjMtKAzEYhQMqWOo8gZt5AAdymdzcSfEGA4J046pkkj9jpJOUJCP07a3Vs_kOfIdzgRotFem5lBhTIi_RihJOOikEv0ZNKV_4FIFVj8kKfQxh-qwxxOmunXJaojtXE117yKmCrSHF1qfc2hRrTvuzsmmelxis-bWlLcdSYS737Tt08G32i6ngbtCVN_sCzT_XaPv0uN28dMPb8-vmYeiCxrXTjnovlZQjV5xyP1rDsATbU0W9wCOMjjJQwPxp4jw4TS0xjOq-ZyP3mq3R7d9tAIDdIYfZ5OOOaya0oOwHvgJO8w</recordid><startdate>201106</startdate><enddate>201106</enddate><creator>Durham, R. A.</creator><creator>Durham, M. O.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201106</creationdate><title>Lightning, grounding, and protection for control and communications systems: Re-evaluated</title><author>Durham, R. A. ; Durham, M. O.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-9d2ff7877b58525fbca307ec4282f60bebd23e8e3f77bdfed92c1a329443b5f93</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Air Terminals</topic><topic>Conductivity</topic><topic>Electric potential</topic><topic>Electrodes</topic><topic>Ground Radials</topic><topic>Ground Ring</topic><topic>Grounding</topic><topic>Lightning</topic><topic>Lightning Protection</topic><topic>Poles and towers</topic><topic>Soil</topic><toplevel>online_resources</toplevel><creatorcontrib>Durham, R. A.</creatorcontrib><creatorcontrib>Durham, M. O.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Durham, R. A.</au><au>Durham, M. O.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Lightning, grounding, and protection for control and communications systems: Re-evaluated</atitle><btitle>Petroleum and Chemical Industry Conference Europe Electrical and Instrumentation Applications</btitle><stitle>PCICEUROPE</stitle><date>2011-06</date><risdate>2011</risdate><spage>1</spage><epage>11</epage><pages>1-11</pages><issn>2151-7665</issn><isbn>9781457700217</isbn><isbn>1457700212</isbn><abstract>Protection for installations that have been modernized or retrofitted presents a unique mix of problems that require a different perspective from a new installation. The paper addresses lightning, transients, and radiation that causes problems on programmable logic controllers, distributed control systems, and remote electronic transducers. While complex grounding grids and networks were not often required for analog systems, digital equipment requires a more effective means of maintaining equal potential throughout the facility. Methods of protecting circuits include a variety of sophisticated and not so elegant techniques. Special consideration must be given to the impact that towers have on a protection system. The investigation ranges from no air terminals to lightning arrays. The protection problem is compounded when different soils such as clay and rock are encountered. Methods of calculating the grounding circuit resistance are identified. Although the paper is based on a retrofit to a pipeline station, the techniques are appropriate for any industrial installation using distributed control.</abstract><pub>IEEE</pub><tpages>11</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 2151-7665
ispartof Petroleum and Chemical Industry Conference Europe Electrical and Instrumentation Applications, 2011, p.1-11
issn 2151-7665
language eng
recordid cdi_ieee_primary_5936962
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Air Terminals
Conductivity
Electric potential
Electrodes
Ground Radials
Ground Ring
Grounding
Lightning
Lightning Protection
Poles and towers
Soil
title Lightning, grounding, and protection for control and communications systems: Re-evaluated
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T03%3A59%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Lightning,%20grounding,%20and%20protection%20for%20control%20and%20communications%20systems:%20Re-evaluated&rft.btitle=Petroleum%20and%20Chemical%20Industry%20Conference%20Europe%20Electrical%20and%20Instrumentation%20Applications&rft.au=Durham,%20R.%20A.&rft.date=2011-06&rft.spage=1&rft.epage=11&rft.pages=1-11&rft.issn=2151-7665&rft.isbn=9781457700217&rft.isbn_list=1457700212&rft_id=info:doi/&rft_dat=%3Cieee_6IE%3E5936962%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=5936962&rfr_iscdi=true