Wastewater treatment and clean production in a coated paper mill

The plant products coated white paper with implementing clean production, which toke UASB-aerobic biological treatment system to treat the wastewater and pollutant. Although the new emission standard is deeply rigid, the emission wastewater could satisfy National standard 18918 Grade 1A which is mor...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Xikai Fei, Yanling He, Xun'an Li, Cuiping Zhang, Qingyi Wang
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1374
container_issue
container_start_page 1372
container_title
container_volume 2
creator Xikai Fei
Yanling He
Xun'an Li
Cuiping Zhang
Qingyi Wang
description The plant products coated white paper with implementing clean production, which toke UASB-aerobic biological treatment system to treat the wastewater and pollutant. Although the new emission standard is deeply rigid, the emission wastewater could satisfy National standard 18918 Grade 1A which is more strictly than National standard 3544-2008. The whole treatment system reduced pollutants to 4.5% and the emission water could be reused. The activated sludge system is maintaining DO at a low level between 0.96 and 1.15mg·L -1 ,and HRT 11hrs,which helped to reduce power, and it explains that activated sludge system has great ability to save energy. When the plant toke measures to water-saving, the product consumed fresh water only 7-9 m 3 ·t -1 much below the half of National standard 3544-2008 requirement.
doi_str_mv 10.1109/ISWREP.2011.5893275
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_5893275</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5893275</ieee_id><sourcerecordid>5893275</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-a9bd338d7a9b134ff7b235b80c6b64c4bc3e7d93e22e2057e5a9e220f9de88483</originalsourceid><addsrcrecordid>eNpVT9tKAzEUjIig1P2CvuQHds1tN8mbUqoWCooW-ljOJmchsjeyEfHvDdiXzsvMwMzhDCFrzirOmX3YfR4_tu-VYJxXtbFS6PqKFFYb3nBhlJRGXV94y29JsSxfLKNprOH6jjweYUn4AwkjTREhDTgmCqOnrkcY6Rwn_-1SmEYaRgrUTTnq6QxzLgyh7-_JTQf9gsWZV-TwvD1sXsv928tu87Qvg2WpBNv6_JDXWXCpuk63QtatYa5pG-VU6yRqbyUKgYLVGmuwWbPOejRGGbki6_-zARFPcwwDxN_Tebb8AxnhS8w</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Wastewater treatment and clean production in a coated paper mill</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Xikai Fei ; Yanling He ; Xun'an Li ; Cuiping Zhang ; Qingyi Wang</creator><creatorcontrib>Xikai Fei ; Yanling He ; Xun'an Li ; Cuiping Zhang ; Qingyi Wang</creatorcontrib><description>The plant products coated white paper with implementing clean production, which toke UASB-aerobic biological treatment system to treat the wastewater and pollutant. Although the new emission standard is deeply rigid, the emission wastewater could satisfy National standard 18918 Grade 1A which is more strictly than National standard 3544-2008. The whole treatment system reduced pollutants to 4.5% and the emission water could be reused. The activated sludge system is maintaining DO at a low level between 0.96 and 1.15mg·L -1 ,and HRT 11hrs,which helped to reduce power, and it explains that activated sludge system has great ability to save energy. When the plant toke measures to water-saving, the product consumed fresh water only 7-9 m 3 ·t -1 much below the half of National standard 3544-2008 requirement.</description><identifier>ISBN: 9781612843391</identifier><identifier>ISBN: 1612843395</identifier><identifier>EISBN: 9781612843384</identifier><identifier>EISBN: 1612843387</identifier><identifier>EISBN: 9781612843407</identifier><identifier>EISBN: 1612843409</identifier><identifier>DOI: 10.1109/ISWREP.2011.5893275</identifier><language>eng</language><publisher>IEEE</publisher><subject>clean production ; coated white paper ; Conferences ; Paper mills ; Wastewater ; Wastewater treatment ; Water pollution ; Water resources</subject><ispartof>2011 International Symposium on Water Resource and Environmental Protection, 2011, Vol.2, p.1372-1374</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5893275$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,27902,54895</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5893275$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Xikai Fei</creatorcontrib><creatorcontrib>Yanling He</creatorcontrib><creatorcontrib>Xun'an Li</creatorcontrib><creatorcontrib>Cuiping Zhang</creatorcontrib><creatorcontrib>Qingyi Wang</creatorcontrib><title>Wastewater treatment and clean production in a coated paper mill</title><title>2011 International Symposium on Water Resource and Environmental Protection</title><addtitle>ISWREP</addtitle><description>The plant products coated white paper with implementing clean production, which toke UASB-aerobic biological treatment system to treat the wastewater and pollutant. Although the new emission standard is deeply rigid, the emission wastewater could satisfy National standard 18918 Grade 1A which is more strictly than National standard 3544-2008. The whole treatment system reduced pollutants to 4.5% and the emission water could be reused. The activated sludge system is maintaining DO at a low level between 0.96 and 1.15mg·L -1 ,and HRT 11hrs,which helped to reduce power, and it explains that activated sludge system has great ability to save energy. When the plant toke measures to water-saving, the product consumed fresh water only 7-9 m 3 ·t -1 much below the half of National standard 3544-2008 requirement.</description><subject>clean production</subject><subject>coated white paper</subject><subject>Conferences</subject><subject>Paper mills</subject><subject>Wastewater</subject><subject>Wastewater treatment</subject><subject>Water pollution</subject><subject>Water resources</subject><isbn>9781612843391</isbn><isbn>1612843395</isbn><isbn>9781612843384</isbn><isbn>1612843387</isbn><isbn>9781612843407</isbn><isbn>1612843409</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2011</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNpVT9tKAzEUjIig1P2CvuQHds1tN8mbUqoWCooW-ljOJmchsjeyEfHvDdiXzsvMwMzhDCFrzirOmX3YfR4_tu-VYJxXtbFS6PqKFFYb3nBhlJRGXV94y29JsSxfLKNprOH6jjweYUn4AwkjTREhDTgmCqOnrkcY6Rwn_-1SmEYaRgrUTTnq6QxzLgyh7-_JTQf9gsWZV-TwvD1sXsv928tu87Qvg2WpBNv6_JDXWXCpuk63QtatYa5pG-VU6yRqbyUKgYLVGmuwWbPOejRGGbki6_-zARFPcwwDxN_Tebb8AxnhS8w</recordid><startdate>201105</startdate><enddate>201105</enddate><creator>Xikai Fei</creator><creator>Yanling He</creator><creator>Xun'an Li</creator><creator>Cuiping Zhang</creator><creator>Qingyi Wang</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201105</creationdate><title>Wastewater treatment and clean production in a coated paper mill</title><author>Xikai Fei ; Yanling He ; Xun'an Li ; Cuiping Zhang ; Qingyi Wang</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-a9bd338d7a9b134ff7b235b80c6b64c4bc3e7d93e22e2057e5a9e220f9de88483</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2011</creationdate><topic>clean production</topic><topic>coated white paper</topic><topic>Conferences</topic><topic>Paper mills</topic><topic>Wastewater</topic><topic>Wastewater treatment</topic><topic>Water pollution</topic><topic>Water resources</topic><toplevel>online_resources</toplevel><creatorcontrib>Xikai Fei</creatorcontrib><creatorcontrib>Yanling He</creatorcontrib><creatorcontrib>Xun'an Li</creatorcontrib><creatorcontrib>Cuiping Zhang</creatorcontrib><creatorcontrib>Qingyi Wang</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Xikai Fei</au><au>Yanling He</au><au>Xun'an Li</au><au>Cuiping Zhang</au><au>Qingyi Wang</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Wastewater treatment and clean production in a coated paper mill</atitle><btitle>2011 International Symposium on Water Resource and Environmental Protection</btitle><stitle>ISWREP</stitle><date>2011-05</date><risdate>2011</risdate><volume>2</volume><spage>1372</spage><epage>1374</epage><pages>1372-1374</pages><isbn>9781612843391</isbn><isbn>1612843395</isbn><eisbn>9781612843384</eisbn><eisbn>1612843387</eisbn><eisbn>9781612843407</eisbn><eisbn>1612843409</eisbn><abstract>The plant products coated white paper with implementing clean production, which toke UASB-aerobic biological treatment system to treat the wastewater and pollutant. Although the new emission standard is deeply rigid, the emission wastewater could satisfy National standard 18918 Grade 1A which is more strictly than National standard 3544-2008. The whole treatment system reduced pollutants to 4.5% and the emission water could be reused. The activated sludge system is maintaining DO at a low level between 0.96 and 1.15mg·L -1 ,and HRT 11hrs,which helped to reduce power, and it explains that activated sludge system has great ability to save energy. When the plant toke measures to water-saving, the product consumed fresh water only 7-9 m 3 ·t -1 much below the half of National standard 3544-2008 requirement.</abstract><pub>IEEE</pub><doi>10.1109/ISWREP.2011.5893275</doi><tpages>3</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 9781612843391
ispartof 2011 International Symposium on Water Resource and Environmental Protection, 2011, Vol.2, p.1372-1374
issn
language eng
recordid cdi_ieee_primary_5893275
source IEEE Electronic Library (IEL) Conference Proceedings
subjects clean production
coated white paper
Conferences
Paper mills
Wastewater
Wastewater treatment
Water pollution
Water resources
title Wastewater treatment and clean production in a coated paper mill
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T11%3A12%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Wastewater%20treatment%20and%20clean%20production%20in%20a%20coated%20paper%20mill&rft.btitle=2011%20International%20Symposium%20on%20Water%20Resource%20and%20Environmental%20Protection&rft.au=Xikai%20Fei&rft.date=2011-05&rft.volume=2&rft.spage=1372&rft.epage=1374&rft.pages=1372-1374&rft.isbn=9781612843391&rft.isbn_list=1612843395&rft_id=info:doi/10.1109/ISWREP.2011.5893275&rft_dat=%3Cieee_6IE%3E5893275%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781612843384&rft.eisbn_list=1612843387&rft.eisbn_list=9781612843407&rft.eisbn_list=1612843409&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=5893275&rfr_iscdi=true