Laboratory setup of a grid-tied PM WECS for experimental investigation

This paper presents a laboratory-based implementation of a variable-speed Permanent Magnet (PM) Wind Energy Conversion System (WECS). The theory behind such a system is presented, after which simulated and experimental results are presented. The behavior of a wind turbine is emulated through the use...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Sager, S T, Khan, M A, Barendse, P S
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 529
container_issue
container_start_page 524
container_title
container_volume
creator Sager, S T
Khan, M A
Barendse, P S
description This paper presents a laboratory-based implementation of a variable-speed Permanent Magnet (PM) Wind Energy Conversion System (WECS). The theory behind such a system is presented, after which simulated and experimental results are presented. The behavior of a wind turbine is emulated through the use of a torque-controlled DC-motor coupled to the PMSG. A full back-to-back power converter is employed to rectify and subsequently invert the produced power and supply it to the grid through a LCL-type grid-filter. The control of the PMSG is realized through the appropriate control of the machine-side power converter while the grid-side converter maintains the DC-link voltage while transferring the produced power to the grid.
doi_str_mv 10.1109/ENERGYCON.2010.5771738
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_5771738</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5771738</ieee_id><sourcerecordid>5771738</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-3c6b59c691420339aa925399289128daa7e53554371347063b63db483bf973973</originalsourceid><addsrcrecordid>eNotT21LwzAYjIigzv4CQfIHOpM-eXs-SummUDfRgfhppGs6IrMdaRT37w3Y4-C4-3DcEXLH2ZxzhvfVqnpdfpTr1bxgKZNacw3mjGSoDReFEAiG6XNyPZmUXpJsHD9ZglIIXFyRRW2bIdg4hBMdXfw-0qGjlu6Db_PoXUtfnul7Vb7RbgjU_R5d8F-uj_ZAff_jxuj3NvqhvyEXnT2MLpt0RjaLalM-5vV6-VQ-1LlHFnPYqUbiTmFaxADQWiwkIBYGeWFaa7WTIKUAzUFopqBR0DbCQNOhhsQZuf2v9c657TFtseG0nZ7DH2yBS7I</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Laboratory setup of a grid-tied PM WECS for experimental investigation</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Sager, S T ; Khan, M A ; Barendse, P S</creator><creatorcontrib>Sager, S T ; Khan, M A ; Barendse, P S</creatorcontrib><description>This paper presents a laboratory-based implementation of a variable-speed Permanent Magnet (PM) Wind Energy Conversion System (WECS). The theory behind such a system is presented, after which simulated and experimental results are presented. The behavior of a wind turbine is emulated through the use of a torque-controlled DC-motor coupled to the PMSG. A full back-to-back power converter is employed to rectify and subsequently invert the produced power and supply it to the grid through a LCL-type grid-filter. The control of the PMSG is realized through the appropriate control of the machine-side power converter while the grid-side converter maintains the DC-link voltage while transferring the produced power to the grid.</description><identifier>ISBN: 1424493781</identifier><identifier>ISBN: 9781424493784</identifier><identifier>EISBN: 9781424493807</identifier><identifier>EISBN: 9781424493791</identifier><identifier>EISBN: 1424493803</identifier><identifier>EISBN: 142449379X</identifier><identifier>DOI: 10.1109/ENERGYCON.2010.5771738</identifier><language>eng</language><publisher>IEEE</publisher><subject>Equations ; Generators ; Mathematical model ; Torque ; Voltage measurement ; Wind speed ; Wind turbines</subject><ispartof>2010 IEEE International Energy Conference, 2010, p.524-529</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5771738$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,27902,54895</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5771738$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Sager, S T</creatorcontrib><creatorcontrib>Khan, M A</creatorcontrib><creatorcontrib>Barendse, P S</creatorcontrib><title>Laboratory setup of a grid-tied PM WECS for experimental investigation</title><title>2010 IEEE International Energy Conference</title><addtitle>ENERGYCON</addtitle><description>This paper presents a laboratory-based implementation of a variable-speed Permanent Magnet (PM) Wind Energy Conversion System (WECS). The theory behind such a system is presented, after which simulated and experimental results are presented. The behavior of a wind turbine is emulated through the use of a torque-controlled DC-motor coupled to the PMSG. A full back-to-back power converter is employed to rectify and subsequently invert the produced power and supply it to the grid through a LCL-type grid-filter. The control of the PMSG is realized through the appropriate control of the machine-side power converter while the grid-side converter maintains the DC-link voltage while transferring the produced power to the grid.</description><subject>Equations</subject><subject>Generators</subject><subject>Mathematical model</subject><subject>Torque</subject><subject>Voltage measurement</subject><subject>Wind speed</subject><subject>Wind turbines</subject><isbn>1424493781</isbn><isbn>9781424493784</isbn><isbn>9781424493807</isbn><isbn>9781424493791</isbn><isbn>1424493803</isbn><isbn>142449379X</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2010</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotT21LwzAYjIigzv4CQfIHOpM-eXs-SummUDfRgfhppGs6IrMdaRT37w3Y4-C4-3DcEXLH2ZxzhvfVqnpdfpTr1bxgKZNacw3mjGSoDReFEAiG6XNyPZmUXpJsHD9ZglIIXFyRRW2bIdg4hBMdXfw-0qGjlu6Db_PoXUtfnul7Vb7RbgjU_R5d8F-uj_ZAff_jxuj3NvqhvyEXnT2MLpt0RjaLalM-5vV6-VQ-1LlHFnPYqUbiTmFaxADQWiwkIBYGeWFaa7WTIKUAzUFopqBR0DbCQNOhhsQZuf2v9c657TFtseG0nZ7DH2yBS7I</recordid><startdate>201012</startdate><enddate>201012</enddate><creator>Sager, S T</creator><creator>Khan, M A</creator><creator>Barendse, P S</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201012</creationdate><title>Laboratory setup of a grid-tied PM WECS for experimental investigation</title><author>Sager, S T ; Khan, M A ; Barendse, P S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-3c6b59c691420339aa925399289128daa7e53554371347063b63db483bf973973</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Equations</topic><topic>Generators</topic><topic>Mathematical model</topic><topic>Torque</topic><topic>Voltage measurement</topic><topic>Wind speed</topic><topic>Wind turbines</topic><toplevel>online_resources</toplevel><creatorcontrib>Sager, S T</creatorcontrib><creatorcontrib>Khan, M A</creatorcontrib><creatorcontrib>Barendse, P S</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Sager, S T</au><au>Khan, M A</au><au>Barendse, P S</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Laboratory setup of a grid-tied PM WECS for experimental investigation</atitle><btitle>2010 IEEE International Energy Conference</btitle><stitle>ENERGYCON</stitle><date>2010-12</date><risdate>2010</risdate><spage>524</spage><epage>529</epage><pages>524-529</pages><isbn>1424493781</isbn><isbn>9781424493784</isbn><eisbn>9781424493807</eisbn><eisbn>9781424493791</eisbn><eisbn>1424493803</eisbn><eisbn>142449379X</eisbn><abstract>This paper presents a laboratory-based implementation of a variable-speed Permanent Magnet (PM) Wind Energy Conversion System (WECS). The theory behind such a system is presented, after which simulated and experimental results are presented. The behavior of a wind turbine is emulated through the use of a torque-controlled DC-motor coupled to the PMSG. A full back-to-back power converter is employed to rectify and subsequently invert the produced power and supply it to the grid through a LCL-type grid-filter. The control of the PMSG is realized through the appropriate control of the machine-side power converter while the grid-side converter maintains the DC-link voltage while transferring the produced power to the grid.</abstract><pub>IEEE</pub><doi>10.1109/ENERGYCON.2010.5771738</doi><tpages>6</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 1424493781
ispartof 2010 IEEE International Energy Conference, 2010, p.524-529
issn
language eng
recordid cdi_ieee_primary_5771738
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Equations
Generators
Mathematical model
Torque
Voltage measurement
Wind speed
Wind turbines
title Laboratory setup of a grid-tied PM WECS for experimental investigation
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T09%3A46%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Laboratory%20setup%20of%20a%20grid-tied%20PM%20WECS%20for%20experimental%20investigation&rft.btitle=2010%20IEEE%20International%20Energy%20Conference&rft.au=Sager,%20S%20T&rft.date=2010-12&rft.spage=524&rft.epage=529&rft.pages=524-529&rft.isbn=1424493781&rft.isbn_list=9781424493784&rft_id=info:doi/10.1109/ENERGYCON.2010.5771738&rft_dat=%3Cieee_6IE%3E5771738%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781424493807&rft.eisbn_list=9781424493791&rft.eisbn_list=1424493803&rft.eisbn_list=142449379X&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=5771738&rfr_iscdi=true