Model of an NMR imaging "bird cage" coil: Enhancing axial homogeneity of the magnetic field

A bird cage coil was modified in order to increase the longitudinal magnetic field. This was obtained using a phase difference circuit between the internal wires. model based on the circuit theory. Theoretical results show the advantage of this modified structure.

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Hedjiedj, A., Nadi, M., Kourtiche, D., Rouane, A., Prieur, G.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1982
container_issue
container_start_page 1981
container_title
container_volume 5
creator Hedjiedj, A.
Nadi, M.
Kourtiche, D.
Rouane, A.
Prieur, G.
description A bird cage coil was modified in order to increase the longitudinal magnetic field. This was obtained using a phase difference circuit between the internal wires. model based on the circuit theory. Theoretical results show the advantage of this modified structure.
doi_str_mv 10.1109/IEMBS.1992.5762130
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_5762130</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5762130</ieee_id><sourcerecordid>5762130</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-c52a4d18399b44a807bb03b8021e6961f6d59285bc37e1e13809dbc0927def963</originalsourceid><addsrcrecordid>eNo1UEtLw0AYXBFBrf0Dell6T_12t_vypqVqoVHQ3jyUfXxJV9JEkhzaf2-KdS7DMMzADCG3DKaMgb1fLvKnzymzlk-lVpwJOCPXoA0IMEyp83-hjeSXZNx13zBASsO1uiJfeROxok1BXU3f8g-adq5MdUknPrWRBlfihIYmVQ90UW9dHY6e2ydX0W2za0qsMfWHY77fIh2yNfYp0CJhFW_IReGqDscnHpH182I9f81W7y_L-eMqSxb6LEjuZpEZYa2fzZwB7T0Ib4AzVFaxQkVpuZE-CI0MmTBgow9guY5YWCVG5O6vNiHi5qcdFrSHzekL8Qs3nlFk</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Model of an NMR imaging "bird cage" coil: Enhancing axial homogeneity of the magnetic field</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Hedjiedj, A. ; Nadi, M. ; Kourtiche, D. ; Rouane, A. ; Prieur, G.</creator><creatorcontrib>Hedjiedj, A. ; Nadi, M. ; Kourtiche, D. ; Rouane, A. ; Prieur, G.</creatorcontrib><description>A bird cage coil was modified in order to increase the longitudinal magnetic field. This was obtained using a phase difference circuit between the internal wires. model based on the circuit theory. Theoretical results show the advantage of this modified structure.</description><identifier>ISBN: 0780307852</identifier><identifier>ISBN: 9780780307858</identifier><identifier>EISBN: 0780308166</identifier><identifier>EISBN: 9780780308169</identifier><identifier>DOI: 10.1109/IEMBS.1992.5762130</identifier><language>eng</language><publisher>IEEE</publisher><subject>Biological system modeling ; Instruments ; Magnetic fields ; Magnetic resonance imaging ; Periodic structures ; Wires</subject><ispartof>1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 1992, Vol.5, p.1981-1982</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5762130$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>310,311,781,785,790,791,2059,27927,54922</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5762130$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Hedjiedj, A.</creatorcontrib><creatorcontrib>Nadi, M.</creatorcontrib><creatorcontrib>Kourtiche, D.</creatorcontrib><creatorcontrib>Rouane, A.</creatorcontrib><creatorcontrib>Prieur, G.</creatorcontrib><title>Model of an NMR imaging "bird cage" coil: Enhancing axial homogeneity of the magnetic field</title><title>1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society</title><addtitle>IEMBS</addtitle><description>A bird cage coil was modified in order to increase the longitudinal magnetic field. This was obtained using a phase difference circuit between the internal wires. model based on the circuit theory. Theoretical results show the advantage of this modified structure.</description><subject>Biological system modeling</subject><subject>Instruments</subject><subject>Magnetic fields</subject><subject>Magnetic resonance imaging</subject><subject>Periodic structures</subject><subject>Wires</subject><isbn>0780307852</isbn><isbn>9780780307858</isbn><isbn>0780308166</isbn><isbn>9780780308169</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>1992</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo1UEtLw0AYXBFBrf0Dell6T_12t_vypqVqoVHQ3jyUfXxJV9JEkhzaf2-KdS7DMMzADCG3DKaMgb1fLvKnzymzlk-lVpwJOCPXoA0IMEyp83-hjeSXZNx13zBASsO1uiJfeROxok1BXU3f8g-adq5MdUknPrWRBlfihIYmVQ90UW9dHY6e2ydX0W2za0qsMfWHY77fIh2yNfYp0CJhFW_IReGqDscnHpH182I9f81W7y_L-eMqSxb6LEjuZpEZYa2fzZwB7T0Ib4AzVFaxQkVpuZE-CI0MmTBgow9guY5YWCVG5O6vNiHi5qcdFrSHzekL8Qs3nlFk</recordid><startdate>199210</startdate><enddate>199210</enddate><creator>Hedjiedj, A.</creator><creator>Nadi, M.</creator><creator>Kourtiche, D.</creator><creator>Rouane, A.</creator><creator>Prieur, G.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>199210</creationdate><title>Model of an NMR imaging "bird cage" coil: Enhancing axial homogeneity of the magnetic field</title><author>Hedjiedj, A. ; Nadi, M. ; Kourtiche, D. ; Rouane, A. ; Prieur, G.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-c52a4d18399b44a807bb03b8021e6961f6d59285bc37e1e13809dbc0927def963</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>1992</creationdate><topic>Biological system modeling</topic><topic>Instruments</topic><topic>Magnetic fields</topic><topic>Magnetic resonance imaging</topic><topic>Periodic structures</topic><topic>Wires</topic><toplevel>online_resources</toplevel><creatorcontrib>Hedjiedj, A.</creatorcontrib><creatorcontrib>Nadi, M.</creatorcontrib><creatorcontrib>Kourtiche, D.</creatorcontrib><creatorcontrib>Rouane, A.</creatorcontrib><creatorcontrib>Prieur, G.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Hedjiedj, A.</au><au>Nadi, M.</au><au>Kourtiche, D.</au><au>Rouane, A.</au><au>Prieur, G.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Model of an NMR imaging "bird cage" coil: Enhancing axial homogeneity of the magnetic field</atitle><btitle>1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society</btitle><stitle>IEMBS</stitle><date>1992-10</date><risdate>1992</risdate><volume>5</volume><spage>1981</spage><epage>1982</epage><pages>1981-1982</pages><isbn>0780307852</isbn><isbn>9780780307858</isbn><eisbn>0780308166</eisbn><eisbn>9780780308169</eisbn><abstract>A bird cage coil was modified in order to increase the longitudinal magnetic field. This was obtained using a phase difference circuit between the internal wires. model based on the circuit theory. Theoretical results show the advantage of this modified structure.</abstract><pub>IEEE</pub><doi>10.1109/IEMBS.1992.5762130</doi><tpages>2</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 0780307852
ispartof 1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 1992, Vol.5, p.1981-1982
issn
language eng
recordid cdi_ieee_primary_5762130
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Biological system modeling
Instruments
Magnetic fields
Magnetic resonance imaging
Periodic structures
Wires
title Model of an NMR imaging "bird cage" coil: Enhancing axial homogeneity of the magnetic field
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-18T01%3A35%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Model%20of%20an%20NMR%20imaging%20%22bird%20cage%22%20coil:%20Enhancing%20axial%20homogeneity%20of%20the%20magnetic%20field&rft.btitle=1992%2014th%20Annual%20International%20Conference%20of%20the%20IEEE%20Engineering%20in%20Medicine%20and%20Biology%20Society&rft.au=Hedjiedj,%20A.&rft.date=1992-10&rft.volume=5&rft.spage=1981&rft.epage=1982&rft.pages=1981-1982&rft.isbn=0780307852&rft.isbn_list=9780780307858&rft_id=info:doi/10.1109/IEMBS.1992.5762130&rft_dat=%3Cieee_6IE%3E5762130%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=0780308166&rft.eisbn_list=9780780308169&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=5762130&rfr_iscdi=true