A method for determining the effects of electromagnetic pulse on cardiac pacemakers

As part of a larger effort to investigate the effects of high-altitude electromagnetic pulse (EMP) simulators on medical electronics, a test method was developed to determine the effects of EMP on cardiac pacemakers (CPMs) without subjecting the CPMs to radiated EMP. The method uses experimental and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Ellis, Vincent J.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2836
container_issue
container_start_page 2835
container_title
container_volume 7
creator Ellis, Vincent J.
description As part of a larger effort to investigate the effects of high-altitude electromagnetic pulse (EMP) simulators on medical electronics, a test method was developed to determine the effects of EMP on cardiac pacemakers (CPMs) without subjecting the CPMs to radiated EMP. The method uses experimental and computational techniques to determine the EMP stress applied to a CPM, and subsequently the strength (response) of a CPM under stress. These experimental results were compared to the results of an independent analytical study, and found to be in good agreement. Although the method developed was specific in its application, the method may be applied to electromagnetic interference studies of CPMs and other medical electronics in general.
doi_str_mv 10.1109/IEMBS.1992.5761715
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_5761715</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5761715</ieee_id><sourcerecordid>5761715</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-5873219cc78ed86b89e8f60c5208ea3e14a0c0eb843f268dfc8f7bda304473ba3</originalsourceid><addsrcrecordid>eNo1UMtOAjEUrTEmKvIDuukPDPYxbW-XSBBJMC5gTzrtLVSZGdKpC__eScSzOa_kLA4hj5zNOGf2eb18f9nOuLVipozmhqsrcs8MMMmAa339bwwocUumw_DJRigFwug7sp3TFsuxDzT2mQYsmNvUpe5AyxEpxoi-DLSPFE-jyn3rDh2W5On5-zQg7TvqXQ7JjYHz2LovzMMDuYlubKcXnpDd63K3eKs2H6v1Yr6pkmWlUmCk4NZ7AxhAN2ARomZeCQboJPLaMc-wgVpGoSFED9E0wUlW10Y2Tk7I099sQsT9OafW5Z_95QP5C99wUSo</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>A method for determining the effects of electromagnetic pulse on cardiac pacemakers</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Ellis, Vincent J.</creator><creatorcontrib>Ellis, Vincent J.</creatorcontrib><description>As part of a larger effort to investigate the effects of high-altitude electromagnetic pulse (EMP) simulators on medical electronics, a test method was developed to determine the effects of EMP on cardiac pacemakers (CPMs) without subjecting the CPMs to radiated EMP. The method uses experimental and computational techniques to determine the EMP stress applied to a CPM, and subsequently the strength (response) of a CPM under stress. These experimental results were compared to the results of an independent analytical study, and found to be in good agreement. Although the method developed was specific in its application, the method may be applied to electromagnetic interference studies of CPMs and other medical electronics in general.</description><identifier>ISBN: 0780307852</identifier><identifier>ISBN: 9780780307858</identifier><identifier>EISBN: 0780308166</identifier><identifier>EISBN: 9780780308169</identifier><identifier>DOI: 10.1109/IEMBS.1992.5761715</identifier><language>eng</language><publisher>IEEE</publisher><subject>Atmospheric measurements ; Conductivity ; Lead ; Particle measurements ; Phantoms</subject><ispartof>1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 1992, Vol.7, p.2835-2836</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5761715$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,27902,54895</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5761715$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Ellis, Vincent J.</creatorcontrib><title>A method for determining the effects of electromagnetic pulse on cardiac pacemakers</title><title>1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society</title><addtitle>IEMBS</addtitle><description>As part of a larger effort to investigate the effects of high-altitude electromagnetic pulse (EMP) simulators on medical electronics, a test method was developed to determine the effects of EMP on cardiac pacemakers (CPMs) without subjecting the CPMs to radiated EMP. The method uses experimental and computational techniques to determine the EMP stress applied to a CPM, and subsequently the strength (response) of a CPM under stress. These experimental results were compared to the results of an independent analytical study, and found to be in good agreement. Although the method developed was specific in its application, the method may be applied to electromagnetic interference studies of CPMs and other medical electronics in general.</description><subject>Atmospheric measurements</subject><subject>Conductivity</subject><subject>Lead</subject><subject>Particle measurements</subject><subject>Phantoms</subject><isbn>0780307852</isbn><isbn>9780780307858</isbn><isbn>0780308166</isbn><isbn>9780780308169</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>1992</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo1UMtOAjEUrTEmKvIDuukPDPYxbW-XSBBJMC5gTzrtLVSZGdKpC__eScSzOa_kLA4hj5zNOGf2eb18f9nOuLVipozmhqsrcs8MMMmAa339bwwocUumw_DJRigFwug7sp3TFsuxDzT2mQYsmNvUpe5AyxEpxoi-DLSPFE-jyn3rDh2W5On5-zQg7TvqXQ7JjYHz2LovzMMDuYlubKcXnpDd63K3eKs2H6v1Yr6pkmWlUmCk4NZ7AxhAN2ARomZeCQboJPLaMc-wgVpGoSFED9E0wUlW10Y2Tk7I099sQsT9OafW5Z_95QP5C99wUSo</recordid><startdate>199210</startdate><enddate>199210</enddate><creator>Ellis, Vincent J.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>199210</creationdate><title>A method for determining the effects of electromagnetic pulse on cardiac pacemakers</title><author>Ellis, Vincent J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-5873219cc78ed86b89e8f60c5208ea3e14a0c0eb843f268dfc8f7bda304473ba3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>1992</creationdate><topic>Atmospheric measurements</topic><topic>Conductivity</topic><topic>Lead</topic><topic>Particle measurements</topic><topic>Phantoms</topic><toplevel>online_resources</toplevel><creatorcontrib>Ellis, Vincent J.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Ellis, Vincent J.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>A method for determining the effects of electromagnetic pulse on cardiac pacemakers</atitle><btitle>1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society</btitle><stitle>IEMBS</stitle><date>1992-10</date><risdate>1992</risdate><volume>7</volume><spage>2835</spage><epage>2836</epage><pages>2835-2836</pages><isbn>0780307852</isbn><isbn>9780780307858</isbn><eisbn>0780308166</eisbn><eisbn>9780780308169</eisbn><abstract>As part of a larger effort to investigate the effects of high-altitude electromagnetic pulse (EMP) simulators on medical electronics, a test method was developed to determine the effects of EMP on cardiac pacemakers (CPMs) without subjecting the CPMs to radiated EMP. The method uses experimental and computational techniques to determine the EMP stress applied to a CPM, and subsequently the strength (response) of a CPM under stress. These experimental results were compared to the results of an independent analytical study, and found to be in good agreement. Although the method developed was specific in its application, the method may be applied to electromagnetic interference studies of CPMs and other medical electronics in general.</abstract><pub>IEEE</pub><doi>10.1109/IEMBS.1992.5761715</doi><tpages>2</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 0780307852
ispartof 1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 1992, Vol.7, p.2835-2836
issn
language eng
recordid cdi_ieee_primary_5761715
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Atmospheric measurements
Conductivity
Lead
Particle measurements
Phantoms
title A method for determining the effects of electromagnetic pulse on cardiac pacemakers
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T23%3A37%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=A%20method%20for%20determining%20the%20effects%20of%20electromagnetic%20pulse%20on%20cardiac%20pacemakers&rft.btitle=1992%2014th%20Annual%20International%20Conference%20of%20the%20IEEE%20Engineering%20in%20Medicine%20and%20Biology%20Society&rft.au=Ellis,%20Vincent%20J.&rft.date=1992-10&rft.volume=7&rft.spage=2835&rft.epage=2836&rft.pages=2835-2836&rft.isbn=0780307852&rft.isbn_list=9780780307858&rft_id=info:doi/10.1109/IEMBS.1992.5761715&rft_dat=%3Cieee_6IE%3E5761715%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=0780308166&rft.eisbn_list=9780780308169&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=5761715&rfr_iscdi=true