Analysis and Improving Methods of Efficiency of Solar Energy in Municipal Heating System

This paper introduces the current state of solar heating system among Wanzleben city heating net. In view of low efficiency (only 20-30%) of this system, it analyses the shortcomings of this applied system from sensors' situation, fixed flow problem, the influence of the user's water tempe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Mingsan Ouyang, Beyer, H G, Yongjian Ding
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 4
container_issue
container_start_page 1
container_title
container_volume
creator Mingsan Ouyang
Beyer, H G
Yongjian Ding
description This paper introduces the current state of solar heating system among Wanzleben city heating net. In view of low efficiency (only 20-30%) of this system, it analyses the shortcomings of this applied system from sensors' situation, fixed flow problem, the influence of the user's water temperature and the length of pipe separately. Some improving methods which are effective by theoretical analysis are suggested. The implementation steps have to be discussed in more detail with the utility.
doi_str_mv 10.1109/APPEEC.2011.5748434
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_5748434</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5748434</ieee_id><sourcerecordid>5748434</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-60f2de2c650c71a5281582da5661cdbf68cd26511e03b3edfe31b3f385a4b68c3</originalsourceid><addsrcrecordid>eNpVkM1Kw0AcxFdUsNQ-QS_7Aqn73-8cQ4i20GKhCt7KJrtbV9JNyUYhb2-LvTiXYfgxcxiE5kAWACR_KrbbqioXlAAshOKaM36DZrnSwCnnkgrOb_9lpu7QhIJQGdcsf0CzlL7IWVLmPFcT9FFE044pJGyixavjqe9-QjzgjRs-O5tw53HlfWiCi814SbuuNT2uousPIw4Rb77jmZ5Mi5fODJfqbkyDOz6ie2_a5GZXn6L35-qtXGbr15dVWayzAEoMmSSeWkcbKUijwAiqQWhqjZASGlt7qRtLpQBwhNXMWe8Y1MwzLQyvz5BN0fxvNzjn9qc-HE0_7q_fsF-_-FXv</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Analysis and Improving Methods of Efficiency of Solar Energy in Municipal Heating System</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Mingsan Ouyang ; Beyer, H G ; Yongjian Ding</creator><creatorcontrib>Mingsan Ouyang ; Beyer, H G ; Yongjian Ding</creatorcontrib><description>This paper introduces the current state of solar heating system among Wanzleben city heating net. In view of low efficiency (only 20-30%) of this system, it analyses the shortcomings of this applied system from sensors' situation, fixed flow problem, the influence of the user's water temperature and the length of pipe separately. Some improving methods which are effective by theoretical analysis are suggested. The implementation steps have to be discussed in more detail with the utility.</description><identifier>ISSN: 2157-4839</identifier><identifier>ISBN: 9781424462537</identifier><identifier>ISBN: 1424462533</identifier><identifier>EISBN: 9781424462544</identifier><identifier>EISBN: 142446255X</identifier><identifier>EISBN: 9781424462551</identifier><identifier>EISBN: 1424462541</identifier><identifier>DOI: 10.1109/APPEEC.2011.5748434</identifier><language>eng</language><publisher>IEEE</publisher><subject>Fluids ; Solar energy ; Solar heating ; Temperature measurement ; Temperature sensors ; Water heating</subject><ispartof>2011 Asia-Pacific Power and Energy Engineering Conference, 2011, p.1-4</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5748434$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5748434$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Mingsan Ouyang</creatorcontrib><creatorcontrib>Beyer, H G</creatorcontrib><creatorcontrib>Yongjian Ding</creatorcontrib><title>Analysis and Improving Methods of Efficiency of Solar Energy in Municipal Heating System</title><title>2011 Asia-Pacific Power and Energy Engineering Conference</title><addtitle>APPEEC</addtitle><description>This paper introduces the current state of solar heating system among Wanzleben city heating net. In view of low efficiency (only 20-30%) of this system, it analyses the shortcomings of this applied system from sensors' situation, fixed flow problem, the influence of the user's water temperature and the length of pipe separately. Some improving methods which are effective by theoretical analysis are suggested. The implementation steps have to be discussed in more detail with the utility.</description><subject>Fluids</subject><subject>Solar energy</subject><subject>Solar heating</subject><subject>Temperature measurement</subject><subject>Temperature sensors</subject><subject>Water heating</subject><issn>2157-4839</issn><isbn>9781424462537</isbn><isbn>1424462533</isbn><isbn>9781424462544</isbn><isbn>142446255X</isbn><isbn>9781424462551</isbn><isbn>1424462541</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2011</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNpVkM1Kw0AcxFdUsNQ-QS_7Aqn73-8cQ4i20GKhCt7KJrtbV9JNyUYhb2-LvTiXYfgxcxiE5kAWACR_KrbbqioXlAAshOKaM36DZrnSwCnnkgrOb_9lpu7QhIJQGdcsf0CzlL7IWVLmPFcT9FFE044pJGyixavjqe9-QjzgjRs-O5tw53HlfWiCi814SbuuNT2uousPIw4Rb77jmZ5Mi5fODJfqbkyDOz6ie2_a5GZXn6L35-qtXGbr15dVWayzAEoMmSSeWkcbKUijwAiqQWhqjZASGlt7qRtLpQBwhNXMWe8Y1MwzLQyvz5BN0fxvNzjn9qc-HE0_7q_fsF-_-FXv</recordid><startdate>201103</startdate><enddate>201103</enddate><creator>Mingsan Ouyang</creator><creator>Beyer, H G</creator><creator>Yongjian Ding</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201103</creationdate><title>Analysis and Improving Methods of Efficiency of Solar Energy in Municipal Heating System</title><author>Mingsan Ouyang ; Beyer, H G ; Yongjian Ding</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-60f2de2c650c71a5281582da5661cdbf68cd26511e03b3edfe31b3f385a4b68c3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Fluids</topic><topic>Solar energy</topic><topic>Solar heating</topic><topic>Temperature measurement</topic><topic>Temperature sensors</topic><topic>Water heating</topic><toplevel>online_resources</toplevel><creatorcontrib>Mingsan Ouyang</creatorcontrib><creatorcontrib>Beyer, H G</creatorcontrib><creatorcontrib>Yongjian Ding</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Mingsan Ouyang</au><au>Beyer, H G</au><au>Yongjian Ding</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Analysis and Improving Methods of Efficiency of Solar Energy in Municipal Heating System</atitle><btitle>2011 Asia-Pacific Power and Energy Engineering Conference</btitle><stitle>APPEEC</stitle><date>2011-03</date><risdate>2011</risdate><spage>1</spage><epage>4</epage><pages>1-4</pages><issn>2157-4839</issn><isbn>9781424462537</isbn><isbn>1424462533</isbn><eisbn>9781424462544</eisbn><eisbn>142446255X</eisbn><eisbn>9781424462551</eisbn><eisbn>1424462541</eisbn><abstract>This paper introduces the current state of solar heating system among Wanzleben city heating net. In view of low efficiency (only 20-30%) of this system, it analyses the shortcomings of this applied system from sensors' situation, fixed flow problem, the influence of the user's water temperature and the length of pipe separately. Some improving methods which are effective by theoretical analysis are suggested. The implementation steps have to be discussed in more detail with the utility.</abstract><pub>IEEE</pub><doi>10.1109/APPEEC.2011.5748434</doi><tpages>4</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 2157-4839
ispartof 2011 Asia-Pacific Power and Energy Engineering Conference, 2011, p.1-4
issn 2157-4839
language eng
recordid cdi_ieee_primary_5748434
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Fluids
Solar energy
Solar heating
Temperature measurement
Temperature sensors
Water heating
title Analysis and Improving Methods of Efficiency of Solar Energy in Municipal Heating System
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T13%3A50%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Analysis%20and%20Improving%20Methods%20of%20Efficiency%20of%20Solar%20Energy%20in%20Municipal%20Heating%20System&rft.btitle=2011%20Asia-Pacific%20Power%20and%20Energy%20Engineering%20Conference&rft.au=Mingsan%20Ouyang&rft.date=2011-03&rft.spage=1&rft.epage=4&rft.pages=1-4&rft.issn=2157-4839&rft.isbn=9781424462537&rft.isbn_list=1424462533&rft_id=info:doi/10.1109/APPEEC.2011.5748434&rft_dat=%3Cieee_6IE%3E5748434%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781424462544&rft.eisbn_list=142446255X&rft.eisbn_list=9781424462551&rft.eisbn_list=1424462541&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=5748434&rfr_iscdi=true