Fusion of MSCT imaging, Electro-Anatomical Mapping and Speckle Tracking Echocardiography for the characterization of local electro-mechanical delays in CRT optimization
In this work, we sought to assist the optimization of Cardiac Resynchronization Therapy (CRT) through the characterization of electro-mechanical delays for each region of the Left Ventricle. This characterization is based on the fusion of electrical, mechanical and anatomical data acquired from Elec...
Gespeichert in:
Hauptverfasser: | , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 404 |
---|---|
container_issue | |
container_start_page | 401 |
container_title | |
container_volume | |
creator | Tavard, F Simon, A Donal, E Hernández, A I Garreau, M |
description | In this work, we sought to assist the optimization of Cardiac Resynchronization Therapy (CRT) through the characterization of electro-mechanical delays for each region of the Left Ventricle. This characterization is based on the fusion of electrical, mechanical and anatomical data acquired from Electro-Anatomical Mapping (EAM), Speckle Tracking Echocardiography (STE) and Multislice CT (MSCT) imaging, respectively. Using MSCT as a reference, the first step is the registration of EAM 3D maps and STE 2D Contours on extracted MSCT LV-surfaces. After this registration step, local electrical and mechanical activation times can be displayed in the same space through 2D quantitative maps, therefore allowing the computation of local electro-mechanical delays. Local and global electro-mechanical delays from septal and lateral walls were calculated for three patients. The complementary information obtained may be useful for a better patient selection for CRT. |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_5737994</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5737994</ieee_id><sourcerecordid>5737994</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-bd3278cb4973495d60133d3a1b4ce99d41f9730398faef734496875d9e0812313</originalsourceid><addsrcrecordid>eNo1kE1OwzAQRs2fRFt6AjY-AJHi2I7tZRW1FKkVEg3ryrUnjWkSR05YlBNxTFIIq5Hme_M9aa7QlLCEMUGJ4tdoktCER1JyeoPmSsj_TCa3aBInIo1SLtg9mnbdRxwTpQSfoO_VZ-d8g32Bt7ssx67WR9ccn_CyAtMHHy0a3fvaGV3hrW7bIcO6sXjXgjlVgPOgzemyXJrSGx2s88eg2_KMCx9wXwI2pR6YHoL70v2oqvylD0ZFDQPT_CosVPrcYdfg7C3Hvu1dPZ49oLtCVx3MxzlD76tlnq2jzevzS7bYRI4I3kcHSxMhzYEpQZniNo0JpZZqcmAGlLKMFEMSUyULDcXAMJVKwa2CWJKEEjpDj3-9DgD2bRgeEs57LqhQitEfZh1tcg</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Fusion of MSCT imaging, Electro-Anatomical Mapping and Speckle Tracking Echocardiography for the characterization of local electro-mechanical delays in CRT optimization</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Tavard, F ; Simon, A ; Donal, E ; Hernández, A I ; Garreau, M</creator><creatorcontrib>Tavard, F ; Simon, A ; Donal, E ; Hernández, A I ; Garreau, M</creatorcontrib><description>In this work, we sought to assist the optimization of Cardiac Resynchronization Therapy (CRT) through the characterization of electro-mechanical delays for each region of the Left Ventricle. This characterization is based on the fusion of electrical, mechanical and anatomical data acquired from Electro-Anatomical Mapping (EAM), Speckle Tracking Echocardiography (STE) and Multislice CT (MSCT) imaging, respectively. Using MSCT as a reference, the first step is the registration of EAM 3D maps and STE 2D Contours on extracted MSCT LV-surfaces. After this registration step, local electrical and mechanical activation times can be displayed in the same space through 2D quantitative maps, therefore allowing the computation of local electro-mechanical delays. Local and global electro-mechanical delays from septal and lateral walls were calculated for three patients. The complementary information obtained may be useful for a better patient selection for CRT.</description><identifier>ISSN: 0276-6574</identifier><identifier>ISBN: 9781424473182</identifier><identifier>ISBN: 1424473187</identifier><identifier>EISSN: 2325-8853</identifier><identifier>EISBN: 1424473195</identifier><identifier>EISBN: 9781424473199</identifier><language>eng</language><publisher>IEEE</publisher><subject>Biomedical imaging ; Cathode ray tubes ; Delay ; Heart ; Strain ; Three dimensional displays</subject><ispartof>2010 Computing in Cardiology, 2010, p.401-404</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5737994$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5737994$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Tavard, F</creatorcontrib><creatorcontrib>Simon, A</creatorcontrib><creatorcontrib>Donal, E</creatorcontrib><creatorcontrib>Hernández, A I</creatorcontrib><creatorcontrib>Garreau, M</creatorcontrib><title>Fusion of MSCT imaging, Electro-Anatomical Mapping and Speckle Tracking Echocardiography for the characterization of local electro-mechanical delays in CRT optimization</title><title>2010 Computing in Cardiology</title><addtitle>CIC</addtitle><description>In this work, we sought to assist the optimization of Cardiac Resynchronization Therapy (CRT) through the characterization of electro-mechanical delays for each region of the Left Ventricle. This characterization is based on the fusion of electrical, mechanical and anatomical data acquired from Electro-Anatomical Mapping (EAM), Speckle Tracking Echocardiography (STE) and Multislice CT (MSCT) imaging, respectively. Using MSCT as a reference, the first step is the registration of EAM 3D maps and STE 2D Contours on extracted MSCT LV-surfaces. After this registration step, local electrical and mechanical activation times can be displayed in the same space through 2D quantitative maps, therefore allowing the computation of local electro-mechanical delays. Local and global electro-mechanical delays from septal and lateral walls were calculated for three patients. The complementary information obtained may be useful for a better patient selection for CRT.</description><subject>Biomedical imaging</subject><subject>Cathode ray tubes</subject><subject>Delay</subject><subject>Heart</subject><subject>Strain</subject><subject>Three dimensional displays</subject><issn>0276-6574</issn><issn>2325-8853</issn><isbn>9781424473182</isbn><isbn>1424473187</isbn><isbn>1424473195</isbn><isbn>9781424473199</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2010</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo1kE1OwzAQRs2fRFt6AjY-AJHi2I7tZRW1FKkVEg3ryrUnjWkSR05YlBNxTFIIq5Hme_M9aa7QlLCEMUGJ4tdoktCER1JyeoPmSsj_TCa3aBInIo1SLtg9mnbdRxwTpQSfoO_VZ-d8g32Bt7ssx67WR9ccn_CyAtMHHy0a3fvaGV3hrW7bIcO6sXjXgjlVgPOgzemyXJrSGx2s88eg2_KMCx9wXwI2pR6YHoL70v2oqvylD0ZFDQPT_CosVPrcYdfg7C3Hvu1dPZ49oLtCVx3MxzlD76tlnq2jzevzS7bYRI4I3kcHSxMhzYEpQZniNo0JpZZqcmAGlLKMFEMSUyULDcXAMJVKwa2CWJKEEjpDj3-9DgD2bRgeEs57LqhQitEfZh1tcg</recordid><startdate>201009</startdate><enddate>201009</enddate><creator>Tavard, F</creator><creator>Simon, A</creator><creator>Donal, E</creator><creator>Hernández, A I</creator><creator>Garreau, M</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>201009</creationdate><title>Fusion of MSCT imaging, Electro-Anatomical Mapping and Speckle Tracking Echocardiography for the characterization of local electro-mechanical delays in CRT optimization</title><author>Tavard, F ; Simon, A ; Donal, E ; Hernández, A I ; Garreau, M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-bd3278cb4973495d60133d3a1b4ce99d41f9730398faef734496875d9e0812313</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Biomedical imaging</topic><topic>Cathode ray tubes</topic><topic>Delay</topic><topic>Heart</topic><topic>Strain</topic><topic>Three dimensional displays</topic><toplevel>online_resources</toplevel><creatorcontrib>Tavard, F</creatorcontrib><creatorcontrib>Simon, A</creatorcontrib><creatorcontrib>Donal, E</creatorcontrib><creatorcontrib>Hernández, A I</creatorcontrib><creatorcontrib>Garreau, M</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Tavard, F</au><au>Simon, A</au><au>Donal, E</au><au>Hernández, A I</au><au>Garreau, M</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Fusion of MSCT imaging, Electro-Anatomical Mapping and Speckle Tracking Echocardiography for the characterization of local electro-mechanical delays in CRT optimization</atitle><btitle>2010 Computing in Cardiology</btitle><stitle>CIC</stitle><date>2010-09</date><risdate>2010</risdate><spage>401</spage><epage>404</epage><pages>401-404</pages><issn>0276-6574</issn><eissn>2325-8853</eissn><isbn>9781424473182</isbn><isbn>1424473187</isbn><eisbn>1424473195</eisbn><eisbn>9781424473199</eisbn><abstract>In this work, we sought to assist the optimization of Cardiac Resynchronization Therapy (CRT) through the characterization of electro-mechanical delays for each region of the Left Ventricle. This characterization is based on the fusion of electrical, mechanical and anatomical data acquired from Electro-Anatomical Mapping (EAM), Speckle Tracking Echocardiography (STE) and Multislice CT (MSCT) imaging, respectively. Using MSCT as a reference, the first step is the registration of EAM 3D maps and STE 2D Contours on extracted MSCT LV-surfaces. After this registration step, local electrical and mechanical activation times can be displayed in the same space through 2D quantitative maps, therefore allowing the computation of local electro-mechanical delays. Local and global electro-mechanical delays from septal and lateral walls were calculated for three patients. The complementary information obtained may be useful for a better patient selection for CRT.</abstract><pub>IEEE</pub><tpages>4</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0276-6574 |
ispartof | 2010 Computing in Cardiology, 2010, p.401-404 |
issn | 0276-6574 2325-8853 |
language | eng |
recordid | cdi_ieee_primary_5737994 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Biomedical imaging Cathode ray tubes Delay Heart Strain Three dimensional displays |
title | Fusion of MSCT imaging, Electro-Anatomical Mapping and Speckle Tracking Echocardiography for the characterization of local electro-mechanical delays in CRT optimization |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T22%3A42%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Fusion%20of%20MSCT%20imaging,%20Electro-Anatomical%20Mapping%20and%20Speckle%20Tracking%20Echocardiography%20for%20the%20characterization%20of%20local%20electro-mechanical%20delays%20in%20CRT%20optimization&rft.btitle=2010%20Computing%20in%20Cardiology&rft.au=Tavard,%20F&rft.date=2010-09&rft.spage=401&rft.epage=404&rft.pages=401-404&rft.issn=0276-6574&rft.eissn=2325-8853&rft.isbn=9781424473182&rft.isbn_list=1424473187&rft_id=info:doi/&rft_dat=%3Cieee_6IE%3E5737994%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1424473195&rft.eisbn_list=9781424473199&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=5737994&rfr_iscdi=true |