In Vitro Evaluation and Theoretical Modeling of the Dissolution Behavior of a Microbubble Contrast Agent for Ultrasound Imaging
Recent literature has reported increasing interest in using contrast agents for ultrasound imaging, in the form of shelled gas microbubbles, for innovative advanced purposes such as noninvasive targeted imaging and drug delivery. Effectiveness of such agents is time-dependent and is determined by mi...
Gespeichert in:
Veröffentlicht in: | IEEE sensors journal 2012-03, Vol.12 (3), p.496-503 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 503 |
---|---|
container_issue | 3 |
container_start_page | 496 |
container_title | IEEE sensors journal |
container_volume | 12 |
creator | Conversano, Francesco Franchini, R. Lay-Ekuakille, A. Casciaro, S. |
description | Recent literature has reported increasing interest in using contrast agents for ultrasound imaging, in the form of shelled gas microbubbles, for innovative advanced purposes such as noninvasive targeted imaging and drug delivery. Effectiveness of such agents is time-dependent and is determined by microbubble dissolution behavior, a complex phenomenon whose knowledge is still limited. In the present study, we monitored the microbubbles of an experimental phospholipid-shelled perfluorobutane contrast agent through time-scheduled size distribution measurements. The diameter-time curve we obtained for shelled perfluorobutane microbubbles showed a rapid diameter increment up to about 1.4 times the initial value, followed by a slow decrement towards bubble disappearance. This behavior is qualitatively similar to the one theoretically predicted by Kabalnov's model for unshelled bubbles, with an extended lifetime due to shell effect. Kabalnov's model, devised for spontaneous dissolution of unshelled microbubbles, was consequently modified in order to get a proper prediction of experimental results also in the case of encapsulated bubbles. A theoretical diameter-time curve was then derived from this new model and fitted to our experimental data points, to estimate microbubble surface tension and to determine the value of an empirical parameter accounting for the shell effect. The proposed model has the potential to predict the dissolution behavior of all kinds of microbubble contrast agents for ultrasound imaging and the adopted experimental methodology represents a new and simple way to estimate microbubble surface tension, essential also for predicting microbubble oscillation performance. |
doi_str_mv | 10.1109/JSEN.2011.2109707 |
format | Article |
fullrecord | <record><control><sourceid>crossref_RIE</sourceid><recordid>TN_cdi_ieee_primary_5727902</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5727902</ieee_id><sourcerecordid>10_1109_JSEN_2011_2109707</sourcerecordid><originalsourceid>FETCH-LOGICAL-c265t-414367aee46a557f0901c8d52ac5eb232fc3603794fe381eb1adb0167798090c3</originalsourceid><addsrcrecordid>eNo9kE1OwzAQhS0EEqVwAMTGF0jx2HGcLEspUNTCghaxi5x00hqlMbKdSqy4OgmtWM3f955Gj5BrYCMAlt0-v01fRpwBjHg3KqZOyACkTCNQcXra94JFsVAf5-TC-0_GIFNSDcjPrKHvJjhLp3tdtzoY21DdrOlyi9ZhMKWu6cKusTbNhtqKhi3Se-O9rds_9g63em-s62-aLkzpbNEWRY10YpvgtA90vMEm0KpjVnW_sW3nP9vpTWd5Sc4qXXu8OtYhWT1Ml5OnaP76OJuM51HJExmiGGKRKI0YJ1pKVbGMQZmuJdelxIILXpUiYUJlcYUiBSxArwsGiVJZ2rGlGBI4-Hb_ee-wyr-c2Wn3nQPL-wTzPsG8TzA_Jthpbg4ag4j_vFRcZYyLX7uDbl4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>In Vitro Evaluation and Theoretical Modeling of the Dissolution Behavior of a Microbubble Contrast Agent for Ultrasound Imaging</title><source>IEEE Electronic Library (IEL)</source><creator>Conversano, Francesco ; Franchini, R. ; Lay-Ekuakille, A. ; Casciaro, S.</creator><creatorcontrib>Conversano, Francesco ; Franchini, R. ; Lay-Ekuakille, A. ; Casciaro, S.</creatorcontrib><description>Recent literature has reported increasing interest in using contrast agents for ultrasound imaging, in the form of shelled gas microbubbles, for innovative advanced purposes such as noninvasive targeted imaging and drug delivery. Effectiveness of such agents is time-dependent and is determined by microbubble dissolution behavior, a complex phenomenon whose knowledge is still limited. In the present study, we monitored the microbubbles of an experimental phospholipid-shelled perfluorobutane contrast agent through time-scheduled size distribution measurements. The diameter-time curve we obtained for shelled perfluorobutane microbubbles showed a rapid diameter increment up to about 1.4 times the initial value, followed by a slow decrement towards bubble disappearance. This behavior is qualitatively similar to the one theoretically predicted by Kabalnov's model for unshelled bubbles, with an extended lifetime due to shell effect. Kabalnov's model, devised for spontaneous dissolution of unshelled microbubbles, was consequently modified in order to get a proper prediction of experimental results also in the case of encapsulated bubbles. A theoretical diameter-time curve was then derived from this new model and fitted to our experimental data points, to estimate microbubble surface tension and to determine the value of an empirical parameter accounting for the shell effect. The proposed model has the potential to predict the dissolution behavior of all kinds of microbubble contrast agents for ultrasound imaging and the adopted experimental methodology represents a new and simple way to estimate microbubble surface tension, essential also for predicting microbubble oscillation performance.</description><identifier>ISSN: 1530-437X</identifier><identifier>EISSN: 1558-1748</identifier><identifier>DOI: 10.1109/JSEN.2011.2109707</identifier><identifier>CODEN: ISJEAZ</identifier><language>eng</language><publisher>IEEE</publisher><subject>Atmospheric measurements ; Atmospheric modeling ; Biomedical acoustic imaging ; biomedical applications of acoustic radiation ; diffusion processes ; modeling ; Particle measurements ; Predictive models ; Size measurement ; Surface tension ; Time measurement ; ultrasound contrast agents</subject><ispartof>IEEE sensors journal, 2012-03, Vol.12 (3), p.496-503</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c265t-414367aee46a557f0901c8d52ac5eb232fc3603794fe381eb1adb0167798090c3</citedby><cites>FETCH-LOGICAL-c265t-414367aee46a557f0901c8d52ac5eb232fc3603794fe381eb1adb0167798090c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5727902$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,796,27924,27925,54758</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5727902$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Conversano, Francesco</creatorcontrib><creatorcontrib>Franchini, R.</creatorcontrib><creatorcontrib>Lay-Ekuakille, A.</creatorcontrib><creatorcontrib>Casciaro, S.</creatorcontrib><title>In Vitro Evaluation and Theoretical Modeling of the Dissolution Behavior of a Microbubble Contrast Agent for Ultrasound Imaging</title><title>IEEE sensors journal</title><addtitle>JSEN</addtitle><description>Recent literature has reported increasing interest in using contrast agents for ultrasound imaging, in the form of shelled gas microbubbles, for innovative advanced purposes such as noninvasive targeted imaging and drug delivery. Effectiveness of such agents is time-dependent and is determined by microbubble dissolution behavior, a complex phenomenon whose knowledge is still limited. In the present study, we monitored the microbubbles of an experimental phospholipid-shelled perfluorobutane contrast agent through time-scheduled size distribution measurements. The diameter-time curve we obtained for shelled perfluorobutane microbubbles showed a rapid diameter increment up to about 1.4 times the initial value, followed by a slow decrement towards bubble disappearance. This behavior is qualitatively similar to the one theoretically predicted by Kabalnov's model for unshelled bubbles, with an extended lifetime due to shell effect. Kabalnov's model, devised for spontaneous dissolution of unshelled microbubbles, was consequently modified in order to get a proper prediction of experimental results also in the case of encapsulated bubbles. A theoretical diameter-time curve was then derived from this new model and fitted to our experimental data points, to estimate microbubble surface tension and to determine the value of an empirical parameter accounting for the shell effect. The proposed model has the potential to predict the dissolution behavior of all kinds of microbubble contrast agents for ultrasound imaging and the adopted experimental methodology represents a new and simple way to estimate microbubble surface tension, essential also for predicting microbubble oscillation performance.</description><subject>Atmospheric measurements</subject><subject>Atmospheric modeling</subject><subject>Biomedical acoustic imaging</subject><subject>biomedical applications of acoustic radiation</subject><subject>diffusion processes</subject><subject>modeling</subject><subject>Particle measurements</subject><subject>Predictive models</subject><subject>Size measurement</subject><subject>Surface tension</subject><subject>Time measurement</subject><subject>ultrasound contrast agents</subject><issn>1530-437X</issn><issn>1558-1748</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNo9kE1OwzAQhS0EEqVwAMTGF0jx2HGcLEspUNTCghaxi5x00hqlMbKdSqy4OgmtWM3f955Gj5BrYCMAlt0-v01fRpwBjHg3KqZOyACkTCNQcXra94JFsVAf5-TC-0_GIFNSDcjPrKHvJjhLp3tdtzoY21DdrOlyi9ZhMKWu6cKusTbNhtqKhi3Se-O9rds_9g63em-s62-aLkzpbNEWRY10YpvgtA90vMEm0KpjVnW_sW3nP9vpTWd5Sc4qXXu8OtYhWT1Ml5OnaP76OJuM51HJExmiGGKRKI0YJ1pKVbGMQZmuJdelxIILXpUiYUJlcYUiBSxArwsGiVJZ2rGlGBI4-Hb_ee-wyr-c2Wn3nQPL-wTzPsG8TzA_Jthpbg4ag4j_vFRcZYyLX7uDbl4</recordid><startdate>20120301</startdate><enddate>20120301</enddate><creator>Conversano, Francesco</creator><creator>Franchini, R.</creator><creator>Lay-Ekuakille, A.</creator><creator>Casciaro, S.</creator><general>IEEE</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20120301</creationdate><title>In Vitro Evaluation and Theoretical Modeling of the Dissolution Behavior of a Microbubble Contrast Agent for Ultrasound Imaging</title><author>Conversano, Francesco ; Franchini, R. ; Lay-Ekuakille, A. ; Casciaro, S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c265t-414367aee46a557f0901c8d52ac5eb232fc3603794fe381eb1adb0167798090c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Atmospheric measurements</topic><topic>Atmospheric modeling</topic><topic>Biomedical acoustic imaging</topic><topic>biomedical applications of acoustic radiation</topic><topic>diffusion processes</topic><topic>modeling</topic><topic>Particle measurements</topic><topic>Predictive models</topic><topic>Size measurement</topic><topic>Surface tension</topic><topic>Time measurement</topic><topic>ultrasound contrast agents</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Conversano, Francesco</creatorcontrib><creatorcontrib>Franchini, R.</creatorcontrib><creatorcontrib>Lay-Ekuakille, A.</creatorcontrib><creatorcontrib>Casciaro, S.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><jtitle>IEEE sensors journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Conversano, Francesco</au><au>Franchini, R.</au><au>Lay-Ekuakille, A.</au><au>Casciaro, S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>In Vitro Evaluation and Theoretical Modeling of the Dissolution Behavior of a Microbubble Contrast Agent for Ultrasound Imaging</atitle><jtitle>IEEE sensors journal</jtitle><stitle>JSEN</stitle><date>2012-03-01</date><risdate>2012</risdate><volume>12</volume><issue>3</issue><spage>496</spage><epage>503</epage><pages>496-503</pages><issn>1530-437X</issn><eissn>1558-1748</eissn><coden>ISJEAZ</coden><abstract>Recent literature has reported increasing interest in using contrast agents for ultrasound imaging, in the form of shelled gas microbubbles, for innovative advanced purposes such as noninvasive targeted imaging and drug delivery. Effectiveness of such agents is time-dependent and is determined by microbubble dissolution behavior, a complex phenomenon whose knowledge is still limited. In the present study, we monitored the microbubbles of an experimental phospholipid-shelled perfluorobutane contrast agent through time-scheduled size distribution measurements. The diameter-time curve we obtained for shelled perfluorobutane microbubbles showed a rapid diameter increment up to about 1.4 times the initial value, followed by a slow decrement towards bubble disappearance. This behavior is qualitatively similar to the one theoretically predicted by Kabalnov's model for unshelled bubbles, with an extended lifetime due to shell effect. Kabalnov's model, devised for spontaneous dissolution of unshelled microbubbles, was consequently modified in order to get a proper prediction of experimental results also in the case of encapsulated bubbles. A theoretical diameter-time curve was then derived from this new model and fitted to our experimental data points, to estimate microbubble surface tension and to determine the value of an empirical parameter accounting for the shell effect. The proposed model has the potential to predict the dissolution behavior of all kinds of microbubble contrast agents for ultrasound imaging and the adopted experimental methodology represents a new and simple way to estimate microbubble surface tension, essential also for predicting microbubble oscillation performance.</abstract><pub>IEEE</pub><doi>10.1109/JSEN.2011.2109707</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 1530-437X |
ispartof | IEEE sensors journal, 2012-03, Vol.12 (3), p.496-503 |
issn | 1530-437X 1558-1748 |
language | eng |
recordid | cdi_ieee_primary_5727902 |
source | IEEE Electronic Library (IEL) |
subjects | Atmospheric measurements Atmospheric modeling Biomedical acoustic imaging biomedical applications of acoustic radiation diffusion processes modeling Particle measurements Predictive models Size measurement Surface tension Time measurement ultrasound contrast agents |
title | In Vitro Evaluation and Theoretical Modeling of the Dissolution Behavior of a Microbubble Contrast Agent for Ultrasound Imaging |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T01%3A44%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=In%20Vitro%20Evaluation%20and%20Theoretical%20Modeling%20of%20the%20Dissolution%20Behavior%20of%20a%20Microbubble%20Contrast%20Agent%20for%20Ultrasound%20Imaging&rft.jtitle=IEEE%20sensors%20journal&rft.au=Conversano,%20Francesco&rft.date=2012-03-01&rft.volume=12&rft.issue=3&rft.spage=496&rft.epage=503&rft.pages=496-503&rft.issn=1530-437X&rft.eissn=1558-1748&rft.coden=ISJEAZ&rft_id=info:doi/10.1109/JSEN.2011.2109707&rft_dat=%3Ccrossref_RIE%3E10_1109_JSEN_2011_2109707%3C/crossref_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=5727902&rfr_iscdi=true |