Smartening cable connections by an intelligent health monitor system
A new technology for smartening existing cable connections by means of implementing an intelligent heath monitoring system is described. The system is called PD-OL and monitors the condition of power cable connections continuously by means of partial discharge detection and location while the cable...
Gespeichert in:
Hauptverfasser: | , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 7 |
---|---|
container_issue | |
container_start_page | 1 |
container_title | |
container_volume | |
creator | van der Wielen, P C J M Steennis, E F |
description | A new technology for smartening existing cable connections by means of implementing an intelligent heath monitoring system is described. The system is called PD-OL and monitors the condition of power cable connections continuously by means of partial discharge detection and location while the cable connection remains in-service. The system (called PD-OL) is able to locate the origin(s) of PDs from a complete cable connection by using only two inductive sensors, each at one cable termination. Data is measured continuously and measurement results are collected in a centralized Control Center, in which the results are analyzed and interpreted. The paper describes the system and gives field results. The effectiveness in which the system was able to detect weak spots shows to be over 80%. This means the system can help significantly to prevent outages, have continuous insight in risks and determine optimal replacement moments. Thereby intelligence is brought to cable connections. |
doi_str_mv | 10.1109/ISGTEUROPE.2010.5638869 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_5638869</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5638869</ieee_id><sourcerecordid>5638869</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-93ebb03896de4d278a6259f6ddf506a26dd2792c1d30d51b5cb959bb0e3652ab3</originalsourceid><addsrcrecordid>eNo9UEtqwzAUVH_QNPUJuqgu4FR_S8uSumkgkNIk0F2Q7OdExZaLrY1vH0NNZzOPGWZ4DELPlCwoJeZlvVvt88PX9jNfMDKKUnGtlblCD1QwIbSk5PsazRhVMhWaiRuUmExPHtHq9t-j6h4lff9DRigiMpPN0NuusV2E4MMJF9bVgIs2BCiib0OP3YBtwD5EqGt_ghDxGWwdz7hpg49th_uhj9A8orvK1j0kE8_R4T3fLz_SzXa1Xr5uUk8zGVPDwTnCtVEliJJl2iomTaXKspJEWTYeLDOsoCUnpaROFs5IM0aAK8ms43P09NfrAeD42_nx9-E4DcIvOaBScQ</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Smartening cable connections by an intelligent health monitor system</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>van der Wielen, P C J M ; Steennis, E F</creator><creatorcontrib>van der Wielen, P C J M ; Steennis, E F</creatorcontrib><description>A new technology for smartening existing cable connections by means of implementing an intelligent heath monitoring system is described. The system is called PD-OL and monitors the condition of power cable connections continuously by means of partial discharge detection and location while the cable connection remains in-service. The system (called PD-OL) is able to locate the origin(s) of PDs from a complete cable connection by using only two inductive sensors, each at one cable termination. Data is measured continuously and measurement results are collected in a centralized Control Center, in which the results are analyzed and interpreted. The paper describes the system and gives field results. The effectiveness in which the system was able to detect weak spots shows to be over 80%. This means the system can help significantly to prevent outages, have continuous insight in risks and determine optimal replacement moments. Thereby intelligence is brought to cable connections.</description><identifier>ISSN: 2165-4816</identifier><identifier>ISBN: 9781424485086</identifier><identifier>ISBN: 1424485088</identifier><identifier>EISSN: 2165-4824</identifier><identifier>EISBN: 142448510X</identifier><identifier>EISBN: 9781424485093</identifier><identifier>EISBN: 9781424485109</identifier><identifier>EISBN: 1424485096</identifier><identifier>DOI: 10.1109/ISGTEUROPE.2010.5638869</identifier><language>eng</language><publisher>IEEE</publisher><subject>Cable insulation ; defect location ; fault diagnosis ; intelligent networks ; intelligent sensors ; intelligent systems ; Joints ; Monitoring ; Partial discharges ; power cable insulation ; power cable testing ; Power cables ; Sensors ; Temperature measurement</subject><ispartof>2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe), 2010, p.1-7</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5638869$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5638869$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>van der Wielen, P C J M</creatorcontrib><creatorcontrib>Steennis, E F</creatorcontrib><title>Smartening cable connections by an intelligent health monitor system</title><title>2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe)</title><addtitle>ISGTEUROPE</addtitle><description>A new technology for smartening existing cable connections by means of implementing an intelligent heath monitoring system is described. The system is called PD-OL and monitors the condition of power cable connections continuously by means of partial discharge detection and location while the cable connection remains in-service. The system (called PD-OL) is able to locate the origin(s) of PDs from a complete cable connection by using only two inductive sensors, each at one cable termination. Data is measured continuously and measurement results are collected in a centralized Control Center, in which the results are analyzed and interpreted. The paper describes the system and gives field results. The effectiveness in which the system was able to detect weak spots shows to be over 80%. This means the system can help significantly to prevent outages, have continuous insight in risks and determine optimal replacement moments. Thereby intelligence is brought to cable connections.</description><subject>Cable insulation</subject><subject>defect location</subject><subject>fault diagnosis</subject><subject>intelligent networks</subject><subject>intelligent sensors</subject><subject>intelligent systems</subject><subject>Joints</subject><subject>Monitoring</subject><subject>Partial discharges</subject><subject>power cable insulation</subject><subject>power cable testing</subject><subject>Power cables</subject><subject>Sensors</subject><subject>Temperature measurement</subject><issn>2165-4816</issn><issn>2165-4824</issn><isbn>9781424485086</isbn><isbn>1424485088</isbn><isbn>142448510X</isbn><isbn>9781424485093</isbn><isbn>9781424485109</isbn><isbn>1424485096</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2010</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo9UEtqwzAUVH_QNPUJuqgu4FR_S8uSumkgkNIk0F2Q7OdExZaLrY1vH0NNZzOPGWZ4DELPlCwoJeZlvVvt88PX9jNfMDKKUnGtlblCD1QwIbSk5PsazRhVMhWaiRuUmExPHtHq9t-j6h4lff9DRigiMpPN0NuusV2E4MMJF9bVgIs2BCiib0OP3YBtwD5EqGt_ghDxGWwdz7hpg49th_uhj9A8orvK1j0kE8_R4T3fLz_SzXa1Xr5uUk8zGVPDwTnCtVEliJJl2iomTaXKspJEWTYeLDOsoCUnpaROFs5IM0aAK8ms43P09NfrAeD42_nx9-E4DcIvOaBScQ</recordid><startdate>201010</startdate><enddate>201010</enddate><creator>van der Wielen, P C J M</creator><creator>Steennis, E F</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201010</creationdate><title>Smartening cable connections by an intelligent health monitor system</title><author>van der Wielen, P C J M ; Steennis, E F</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-93ebb03896de4d278a6259f6ddf506a26dd2792c1d30d51b5cb959bb0e3652ab3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Cable insulation</topic><topic>defect location</topic><topic>fault diagnosis</topic><topic>intelligent networks</topic><topic>intelligent sensors</topic><topic>intelligent systems</topic><topic>Joints</topic><topic>Monitoring</topic><topic>Partial discharges</topic><topic>power cable insulation</topic><topic>power cable testing</topic><topic>Power cables</topic><topic>Sensors</topic><topic>Temperature measurement</topic><toplevel>online_resources</toplevel><creatorcontrib>van der Wielen, P C J M</creatorcontrib><creatorcontrib>Steennis, E F</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>van der Wielen, P C J M</au><au>Steennis, E F</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Smartening cable connections by an intelligent health monitor system</atitle><btitle>2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe)</btitle><stitle>ISGTEUROPE</stitle><date>2010-10</date><risdate>2010</risdate><spage>1</spage><epage>7</epage><pages>1-7</pages><issn>2165-4816</issn><eissn>2165-4824</eissn><isbn>9781424485086</isbn><isbn>1424485088</isbn><eisbn>142448510X</eisbn><eisbn>9781424485093</eisbn><eisbn>9781424485109</eisbn><eisbn>1424485096</eisbn><abstract>A new technology for smartening existing cable connections by means of implementing an intelligent heath monitoring system is described. The system is called PD-OL and monitors the condition of power cable connections continuously by means of partial discharge detection and location while the cable connection remains in-service. The system (called PD-OL) is able to locate the origin(s) of PDs from a complete cable connection by using only two inductive sensors, each at one cable termination. Data is measured continuously and measurement results are collected in a centralized Control Center, in which the results are analyzed and interpreted. The paper describes the system and gives field results. The effectiveness in which the system was able to detect weak spots shows to be over 80%. This means the system can help significantly to prevent outages, have continuous insight in risks and determine optimal replacement moments. Thereby intelligence is brought to cable connections.</abstract><pub>IEEE</pub><doi>10.1109/ISGTEUROPE.2010.5638869</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 2165-4816 |
ispartof | 2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe), 2010, p.1-7 |
issn | 2165-4816 2165-4824 |
language | eng |
recordid | cdi_ieee_primary_5638869 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Cable insulation defect location fault diagnosis intelligent networks intelligent sensors intelligent systems Joints Monitoring Partial discharges power cable insulation power cable testing Power cables Sensors Temperature measurement |
title | Smartening cable connections by an intelligent health monitor system |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-23T03%3A18%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Smartening%20cable%20connections%20by%20an%20intelligent%20health%20monitor%20system&rft.btitle=2010%20IEEE%20PES%20Innovative%20Smart%20Grid%20Technologies%20Conference%20Europe%20(ISGT%20Europe)&rft.au=van%20der%20Wielen,%20P%20C%20J%20M&rft.date=2010-10&rft.spage=1&rft.epage=7&rft.pages=1-7&rft.issn=2165-4816&rft.eissn=2165-4824&rft.isbn=9781424485086&rft.isbn_list=1424485088&rft_id=info:doi/10.1109/ISGTEUROPE.2010.5638869&rft_dat=%3Cieee_6IE%3E5638869%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=142448510X&rft.eisbn_list=9781424485093&rft.eisbn_list=9781424485109&rft.eisbn_list=1424485096&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=5638869&rfr_iscdi=true |