Evaluation of ambulatory ECG sensors for a clinical trial on outpatient cardiac rehabilitation
The objective of this paper is to investigate an R wave extraction function of the ECG signals from different sensors and electrodes used in an ICT-based home care cardiac rehabilitation (CR) program called the Care Assessment Platform (CAP). The CAP's focus is to provide patients an alternativ...
Gespeichert in:
Hauptverfasser: | , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 243 |
---|---|
container_issue | |
container_start_page | 240 |
container_title | |
container_volume | |
creator | Hang Ding Sarela, A Helmer, R Mestrovic, M Karunanithi, M |
description | The objective of this paper is to investigate an R wave extraction function of the ECG signals from different sensors and electrodes used in an ICT-based home care cardiac rehabilitation (CR) program called the Care Assessment Platform (CAP). The CAP's focus is to provide patients an alternative option to undertake CR program at home to improve the uptake of CR programs that is currently underutilised. The CAP uses ambulatory monitoring devices to collect physiological data such as Heart Rate (HR) for a home setting. In this study we evaluated the performance of HR measurement by testing two ECG sensors and four different brands of electrodes intended for ambulatory use. ECG noise levels and error rates of R-wave extractions were analyzed under different test conditions, activities, and combinations of sensors and electrodes. The results display that the textile electrodes can have better performance than the conventional Ag/AgCl gel based electrodes and the R wave detection error rates for walking activity, the major exercise for the CR patients, are generally lower than 0.6% for all the tested textile electrodes. The study demonstrates that all the tested electrodes and sensors can obtain sufficient ECG signals for heart rate and heart rate variability studies in the CAP. It also indicates that the textile electrodes may outperform the conventional Ag/AgCl gel electrodes in particular to applications of the CR study. |
doi_str_mv | 10.1109/ICCME.2010.5558835 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_5558835</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5558835</ieee_id><sourcerecordid>5558835</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-18e609f77d723cee726fe61cfc9b4cc991ae4cd2debad21a85045fc9e654388d3</originalsourceid><addsrcrecordid>eNo1kM1OwzAQhI0QElDyAnDxC6T4N7GPKAqlUhGXnqk29loYpUnluEh9ewKUPexqNJpPqyHknrMl58w-rpvmtV0KNmuttTFSX5DC1oYroVRllGSX5PZfcHNNimn6ZPMoLVRtbsh7-wX9EXIcBzoGCvvu2EMe04m2zYpOOExjmmgYEwXq-jhEBz3NKc77J3HMhzmLQ6YOko_gaMIP6GIf8y_zjlwF6CcszndBts_ttnkpN2-rdfO0KaNlueQGK2ZDXftaSIdYiypgxV1wtlPOWcsBlfPCYwdecDB6_n82sdJKGuPlgjz8YSMi7g4p7iGddudG5Df5O1ad</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Evaluation of ambulatory ECG sensors for a clinical trial on outpatient cardiac rehabilitation</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Hang Ding ; Sarela, A ; Helmer, R ; Mestrovic, M ; Karunanithi, M</creator><creatorcontrib>Hang Ding ; Sarela, A ; Helmer, R ; Mestrovic, M ; Karunanithi, M</creatorcontrib><description>The objective of this paper is to investigate an R wave extraction function of the ECG signals from different sensors and electrodes used in an ICT-based home care cardiac rehabilitation (CR) program called the Care Assessment Platform (CAP). The CAP's focus is to provide patients an alternative option to undertake CR program at home to improve the uptake of CR programs that is currently underutilised. The CAP uses ambulatory monitoring devices to collect physiological data such as Heart Rate (HR) for a home setting. In this study we evaluated the performance of HR measurement by testing two ECG sensors and four different brands of electrodes intended for ambulatory use. ECG noise levels and error rates of R-wave extractions were analyzed under different test conditions, activities, and combinations of sensors and electrodes. The results display that the textile electrodes can have better performance than the conventional Ag/AgCl gel based electrodes and the R wave detection error rates for walking activity, the major exercise for the CR patients, are generally lower than 0.6% for all the tested textile electrodes. The study demonstrates that all the tested electrodes and sensors can obtain sufficient ECG signals for heart rate and heart rate variability studies in the CAP. It also indicates that the textile electrodes may outperform the conventional Ag/AgCl gel electrodes in particular to applications of the CR study.</description><identifier>ISBN: 1424468418</identifier><identifier>ISBN: 9781424468416</identifier><identifier>EISBN: 9781424468430</identifier><identifier>EISBN: 1424468426</identifier><identifier>EISBN: 1424468434</identifier><identifier>EISBN: 9781424468423</identifier><identifier>DOI: 10.1109/ICCME.2010.5558835</identifier><language>eng</language><publisher>IEEE</publisher><subject>Biomedical monitoring ; Electrocardiography ; Electrodes ; Heart rate variability ; Monitoring ; Noise measurement</subject><ispartof>IEEE/ICME International Conference on Complex Medical Engineering, 2010, p.240-243</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5558835$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2051,27904,54898</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5558835$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Hang Ding</creatorcontrib><creatorcontrib>Sarela, A</creatorcontrib><creatorcontrib>Helmer, R</creatorcontrib><creatorcontrib>Mestrovic, M</creatorcontrib><creatorcontrib>Karunanithi, M</creatorcontrib><title>Evaluation of ambulatory ECG sensors for a clinical trial on outpatient cardiac rehabilitation</title><title>IEEE/ICME International Conference on Complex Medical Engineering</title><addtitle>ICCME</addtitle><description>The objective of this paper is to investigate an R wave extraction function of the ECG signals from different sensors and electrodes used in an ICT-based home care cardiac rehabilitation (CR) program called the Care Assessment Platform (CAP). The CAP's focus is to provide patients an alternative option to undertake CR program at home to improve the uptake of CR programs that is currently underutilised. The CAP uses ambulatory monitoring devices to collect physiological data such as Heart Rate (HR) for a home setting. In this study we evaluated the performance of HR measurement by testing two ECG sensors and four different brands of electrodes intended for ambulatory use. ECG noise levels and error rates of R-wave extractions were analyzed under different test conditions, activities, and combinations of sensors and electrodes. The results display that the textile electrodes can have better performance than the conventional Ag/AgCl gel based electrodes and the R wave detection error rates for walking activity, the major exercise for the CR patients, are generally lower than 0.6% for all the tested textile electrodes. The study demonstrates that all the tested electrodes and sensors can obtain sufficient ECG signals for heart rate and heart rate variability studies in the CAP. It also indicates that the textile electrodes may outperform the conventional Ag/AgCl gel electrodes in particular to applications of the CR study.</description><subject>Biomedical monitoring</subject><subject>Electrocardiography</subject><subject>Electrodes</subject><subject>Heart rate variability</subject><subject>Monitoring</subject><subject>Noise measurement</subject><isbn>1424468418</isbn><isbn>9781424468416</isbn><isbn>9781424468430</isbn><isbn>1424468426</isbn><isbn>1424468434</isbn><isbn>9781424468423</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2010</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo1kM1OwzAQhI0QElDyAnDxC6T4N7GPKAqlUhGXnqk29loYpUnluEh9ewKUPexqNJpPqyHknrMl58w-rpvmtV0KNmuttTFSX5DC1oYroVRllGSX5PZfcHNNimn6ZPMoLVRtbsh7-wX9EXIcBzoGCvvu2EMe04m2zYpOOExjmmgYEwXq-jhEBz3NKc77J3HMhzmLQ6YOko_gaMIP6GIf8y_zjlwF6CcszndBts_ttnkpN2-rdfO0KaNlueQGK2ZDXftaSIdYiypgxV1wtlPOWcsBlfPCYwdecDB6_n82sdJKGuPlgjz8YSMi7g4p7iGddudG5Df5O1ad</recordid><startdate>201007</startdate><enddate>201007</enddate><creator>Hang Ding</creator><creator>Sarela, A</creator><creator>Helmer, R</creator><creator>Mestrovic, M</creator><creator>Karunanithi, M</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201007</creationdate><title>Evaluation of ambulatory ECG sensors for a clinical trial on outpatient cardiac rehabilitation</title><author>Hang Ding ; Sarela, A ; Helmer, R ; Mestrovic, M ; Karunanithi, M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-18e609f77d723cee726fe61cfc9b4cc991ae4cd2debad21a85045fc9e654388d3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Biomedical monitoring</topic><topic>Electrocardiography</topic><topic>Electrodes</topic><topic>Heart rate variability</topic><topic>Monitoring</topic><topic>Noise measurement</topic><toplevel>online_resources</toplevel><creatorcontrib>Hang Ding</creatorcontrib><creatorcontrib>Sarela, A</creatorcontrib><creatorcontrib>Helmer, R</creatorcontrib><creatorcontrib>Mestrovic, M</creatorcontrib><creatorcontrib>Karunanithi, M</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Hang Ding</au><au>Sarela, A</au><au>Helmer, R</au><au>Mestrovic, M</au><au>Karunanithi, M</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Evaluation of ambulatory ECG sensors for a clinical trial on outpatient cardiac rehabilitation</atitle><btitle>IEEE/ICME International Conference on Complex Medical Engineering</btitle><stitle>ICCME</stitle><date>2010-07</date><risdate>2010</risdate><spage>240</spage><epage>243</epage><pages>240-243</pages><isbn>1424468418</isbn><isbn>9781424468416</isbn><eisbn>9781424468430</eisbn><eisbn>1424468426</eisbn><eisbn>1424468434</eisbn><eisbn>9781424468423</eisbn><abstract>The objective of this paper is to investigate an R wave extraction function of the ECG signals from different sensors and electrodes used in an ICT-based home care cardiac rehabilitation (CR) program called the Care Assessment Platform (CAP). The CAP's focus is to provide patients an alternative option to undertake CR program at home to improve the uptake of CR programs that is currently underutilised. The CAP uses ambulatory monitoring devices to collect physiological data such as Heart Rate (HR) for a home setting. In this study we evaluated the performance of HR measurement by testing two ECG sensors and four different brands of electrodes intended for ambulatory use. ECG noise levels and error rates of R-wave extractions were analyzed under different test conditions, activities, and combinations of sensors and electrodes. The results display that the textile electrodes can have better performance than the conventional Ag/AgCl gel based electrodes and the R wave detection error rates for walking activity, the major exercise for the CR patients, are generally lower than 0.6% for all the tested textile electrodes. The study demonstrates that all the tested electrodes and sensors can obtain sufficient ECG signals for heart rate and heart rate variability studies in the CAP. It also indicates that the textile electrodes may outperform the conventional Ag/AgCl gel electrodes in particular to applications of the CR study.</abstract><pub>IEEE</pub><doi>10.1109/ICCME.2010.5558835</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISBN: 1424468418 |
ispartof | IEEE/ICME International Conference on Complex Medical Engineering, 2010, p.240-243 |
issn | |
language | eng |
recordid | cdi_ieee_primary_5558835 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Biomedical monitoring Electrocardiography Electrodes Heart rate variability Monitoring Noise measurement |
title | Evaluation of ambulatory ECG sensors for a clinical trial on outpatient cardiac rehabilitation |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-26T03%3A27%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Evaluation%20of%20ambulatory%20ECG%20sensors%20for%20a%20clinical%20trial%20on%20outpatient%20cardiac%20rehabilitation&rft.btitle=IEEE/ICME%20International%20Conference%20on%20Complex%20Medical%20Engineering&rft.au=Hang%20Ding&rft.date=2010-07&rft.spage=240&rft.epage=243&rft.pages=240-243&rft.isbn=1424468418&rft.isbn_list=9781424468416&rft_id=info:doi/10.1109/ICCME.2010.5558835&rft_dat=%3Cieee_6IE%3E5558835%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781424468430&rft.eisbn_list=1424468426&rft.eisbn_list=1424468434&rft.eisbn_list=9781424468423&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=5558835&rfr_iscdi=true |