About high-voltage insulating of 750 kV circuit-breaker
The study analyses the nonuniform repartition of high voltage on the blow-out chambers of a 750 kV circuit breaker. The authors develop a 750 kV circuit breaker model, on which basis they establish the repartition of a large spectrum of impulse waves. By keeping account of the behaviour of the insul...
Gespeichert in:
Hauptverfasser: | , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 817 vol.2 |
---|---|
container_issue | |
container_start_page | 814 |
container_title | |
container_volume | 2 |
creator | Tusaliu, P. Ciontu, M. Tusaliu, V. |
description | The study analyses the nonuniform repartition of high voltage on the blow-out chambers of a 750 kV circuit breaker. The authors develop a 750 kV circuit breaker model, on which basis they establish the repartition of a large spectrum of impulse waves. By keeping account of the behaviour of the insulation during overvoltage waves and studying the self-capacity and stray capacity of the apparatus construction, they elaborate the circuit breaker model. On this basis, the repartition of impulse voltage waves is studied. |
doi_str_mv | 10.1109/ELINSL.1996.549469 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_549469</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>549469</ieee_id><sourcerecordid>549469</sourcerecordid><originalsourceid>FETCH-ieee_primary_5494693</originalsourceid><addsrcrecordid>eNp9jsEKgjAAQAcVZOUPeNoPzLa2OXeMMAqiSxHdZMrUpWnMGfT3BXXuXd7hXR4AAcEhIVguk8P-eDqERMoo5EyySI7ADIsYU8opEWPgERxLhGN2nQK_72_4A-N8FQkPiHXWDQ5WpqzQs2ucKjU0bT80ypm2hF0BBcewvsDc2HwwDmVWq1rbBZgUqum1__McBNvkvNkho7VOH9bclX2l3x36N74BwIo21A</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>About high-voltage insulating of 750 kV circuit-breaker</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Tusaliu, P. ; Ciontu, M. ; Tusaliu, V.</creator><creatorcontrib>Tusaliu, P. ; Ciontu, M. ; Tusaliu, V.</creatorcontrib><description>The study analyses the nonuniform repartition of high voltage on the blow-out chambers of a 750 kV circuit breaker. The authors develop a 750 kV circuit breaker model, on which basis they establish the repartition of a large spectrum of impulse waves. By keeping account of the behaviour of the insulation during overvoltage waves and studying the self-capacity and stray capacity of the apparatus construction, they elaborate the circuit breaker model. On this basis, the repartition of impulse voltage waves is studied.</description><identifier>ISSN: 1089-084X</identifier><identifier>ISBN: 0780335317</identifier><identifier>ISBN: 9780780335318</identifier><identifier>DOI: 10.1109/ELINSL.1996.549469</identifier><language>eng</language><publisher>IEEE</publisher><subject>Circuit breakers ; Dielectrics and electrical insulation ; Frequency ; Oil insulation ; Petroleum ; Power system reliability ; Power system security ; Resistors ; Stress ; Voltage</subject><ispartof>Conference Record of the 1996 IEEE International Symposium on Electrical Insulation, 1996, Vol.2, p.814-817 vol.2</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/549469$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,4036,4037,27902,54895</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/549469$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Tusaliu, P.</creatorcontrib><creatorcontrib>Ciontu, M.</creatorcontrib><creatorcontrib>Tusaliu, V.</creatorcontrib><title>About high-voltage insulating of 750 kV circuit-breaker</title><title>Conference Record of the 1996 IEEE International Symposium on Electrical Insulation</title><addtitle>ELINSL</addtitle><description>The study analyses the nonuniform repartition of high voltage on the blow-out chambers of a 750 kV circuit breaker. The authors develop a 750 kV circuit breaker model, on which basis they establish the repartition of a large spectrum of impulse waves. By keeping account of the behaviour of the insulation during overvoltage waves and studying the self-capacity and stray capacity of the apparatus construction, they elaborate the circuit breaker model. On this basis, the repartition of impulse voltage waves is studied.</description><subject>Circuit breakers</subject><subject>Dielectrics and electrical insulation</subject><subject>Frequency</subject><subject>Oil insulation</subject><subject>Petroleum</subject><subject>Power system reliability</subject><subject>Power system security</subject><subject>Resistors</subject><subject>Stress</subject><subject>Voltage</subject><issn>1089-084X</issn><isbn>0780335317</isbn><isbn>9780780335318</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>1996</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNp9jsEKgjAAQAcVZOUPeNoPzLa2OXeMMAqiSxHdZMrUpWnMGfT3BXXuXd7hXR4AAcEhIVguk8P-eDqERMoo5EyySI7ADIsYU8opEWPgERxLhGN2nQK_72_4A-N8FQkPiHXWDQ5WpqzQs2ucKjU0bT80ypm2hF0BBcewvsDc2HwwDmVWq1rbBZgUqum1__McBNvkvNkho7VOH9bclX2l3x36N74BwIo21A</recordid><startdate>1996</startdate><enddate>1996</enddate><creator>Tusaliu, P.</creator><creator>Ciontu, M.</creator><creator>Tusaliu, V.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>1996</creationdate><title>About high-voltage insulating of 750 kV circuit-breaker</title><author>Tusaliu, P. ; Ciontu, M. ; Tusaliu, V.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-ieee_primary_5494693</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>1996</creationdate><topic>Circuit breakers</topic><topic>Dielectrics and electrical insulation</topic><topic>Frequency</topic><topic>Oil insulation</topic><topic>Petroleum</topic><topic>Power system reliability</topic><topic>Power system security</topic><topic>Resistors</topic><topic>Stress</topic><topic>Voltage</topic><toplevel>online_resources</toplevel><creatorcontrib>Tusaliu, P.</creatorcontrib><creatorcontrib>Ciontu, M.</creatorcontrib><creatorcontrib>Tusaliu, V.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Tusaliu, P.</au><au>Ciontu, M.</au><au>Tusaliu, V.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>About high-voltage insulating of 750 kV circuit-breaker</atitle><btitle>Conference Record of the 1996 IEEE International Symposium on Electrical Insulation</btitle><stitle>ELINSL</stitle><date>1996</date><risdate>1996</risdate><volume>2</volume><spage>814</spage><epage>817 vol.2</epage><pages>814-817 vol.2</pages><issn>1089-084X</issn><isbn>0780335317</isbn><isbn>9780780335318</isbn><abstract>The study analyses the nonuniform repartition of high voltage on the blow-out chambers of a 750 kV circuit breaker. The authors develop a 750 kV circuit breaker model, on which basis they establish the repartition of a large spectrum of impulse waves. By keeping account of the behaviour of the insulation during overvoltage waves and studying the self-capacity and stray capacity of the apparatus construction, they elaborate the circuit breaker model. On this basis, the repartition of impulse voltage waves is studied.</abstract><pub>IEEE</pub><doi>10.1109/ELINSL.1996.549469</doi></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 1089-084X |
ispartof | Conference Record of the 1996 IEEE International Symposium on Electrical Insulation, 1996, Vol.2, p.814-817 vol.2 |
issn | 1089-084X |
language | eng |
recordid | cdi_ieee_primary_549469 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Circuit breakers Dielectrics and electrical insulation Frequency Oil insulation Petroleum Power system reliability Power system security Resistors Stress Voltage |
title | About high-voltage insulating of 750 kV circuit-breaker |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T13%3A50%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=About%20high-voltage%20insulating%20of%20750%20kV%20circuit-breaker&rft.btitle=Conference%20Record%20of%20the%201996%20IEEE%20International%20Symposium%20on%20Electrical%20Insulation&rft.au=Tusaliu,%20P.&rft.date=1996&rft.volume=2&rft.spage=814&rft.epage=817%20vol.2&rft.pages=814-817%20vol.2&rft.issn=1089-084X&rft.isbn=0780335317&rft.isbn_list=9780780335318&rft_id=info:doi/10.1109/ELINSL.1996.549469&rft_dat=%3Cieee_6IE%3E549469%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=549469&rfr_iscdi=true |