Lessons learned from generator event reports

Generators are critical components of the power system. In addition to being some of the most expensive pieces of equipment on the system, they are also extremely critical to power system stability. A false trip can lead to extensive testing in search of a nonexistent fault, while a delayed trip can...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Scharlach, Rogerio C, Young, Jason
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 23
container_issue
container_start_page 1
container_title
container_volume
creator Scharlach, Rogerio C
Young, Jason
description Generators are critical components of the power system. In addition to being some of the most expensive pieces of equipment on the system, they are also extremely critical to power system stability. A false trip can lead to extensive testing in search of a nonexistent fault, while a delayed trip can result in unnecessary additional damage to equipment. Both misoperations result in excessive equipment outages, increasing the utility's outage costs and placing additional strain on the system. Therefore, the misoperation of protective relay schemes at generating stations is very expensive and must be avoided. This paper analyzes real-world event report data in the interest of uncovering valuable lessons for setting and commissioning generator relays. The paper reviews the application of phase differential relays for protection of the generator stator windings against phase faults and the application of third-harmonic voltage elements for 100 percent stator ground protection. Additionally, the effects of negative-sequence currents and overexcitation on a generator are discussed, as well as the importance of detecting and removing both conditions. With event report data, the paper teaches important lessons to be used in applying each function to protect generators. The paper discusses application limitations and considerations for each case.
doi_str_mv 10.1109/CPRE.2010.5469503
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_5469503</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5469503</ieee_id><sourcerecordid>5469503</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-c31afa9cf2f843f7d65e9fe4d14175261d55dd674ac3b5afa28cbee8fed7eda03</originalsourceid><addsrcrecordid>eNpVj81KAzEUhSMiKHUeQNzkAZyam9z8LWWoVhiwlO5LOrmRkXamJIPg2ztgN57N4YOPA4exBxBLAOGfm812tZRiRo3Ga6GuWOWtA5SIRlh01_9YwS2rSvkSc1BL9OaOPbVUyjgUfqSQB4o85fHEP2mgHKYxc_qmYeKZzmOeyj27SeFYqLr0gu1eV7tmXbcfb-_NS1v3Xkx1pyCk4Lskk0OVbDSafCKMgGC1NBC1jtFYDJ066FmVrjsQuUTRUgxCLdjj32xPRPtz7k8h_-wvF9UvFlhFPQ</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Lessons learned from generator event reports</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Scharlach, Rogerio C ; Young, Jason</creator><creatorcontrib>Scharlach, Rogerio C ; Young, Jason</creatorcontrib><description>Generators are critical components of the power system. In addition to being some of the most expensive pieces of equipment on the system, they are also extremely critical to power system stability. A false trip can lead to extensive testing in search of a nonexistent fault, while a delayed trip can result in unnecessary additional damage to equipment. Both misoperations result in excessive equipment outages, increasing the utility's outage costs and placing additional strain on the system. Therefore, the misoperation of protective relay schemes at generating stations is very expensive and must be avoided. This paper analyzes real-world event report data in the interest of uncovering valuable lessons for setting and commissioning generator relays. The paper reviews the application of phase differential relays for protection of the generator stator windings against phase faults and the application of third-harmonic voltage elements for 100 percent stator ground protection. Additionally, the effects of negative-sequence currents and overexcitation on a generator are discussed, as well as the importance of detecting and removing both conditions. With event report data, the paper teaches important lessons to be used in applying each function to protect generators. The paper discusses application limitations and considerations for each case.</description><identifier>ISBN: 9781424460731</identifier><identifier>ISBN: 1424460735</identifier><identifier>EISBN: 9781424460748</identifier><identifier>EISBN: 1424460743</identifier><identifier>EISBN: 9781424460755</identifier><identifier>EISBN: 1424460751</identifier><identifier>DOI: 10.1109/CPRE.2010.5469503</identifier><language>eng</language><publisher>IEEE</publisher><subject>Capacitive sensors ; Costs ; Delay ; Power generation ; Power system faults ; Power system stability ; Protection ; Protective relaying ; Stator windings ; Testing</subject><ispartof>2010 63rd Annual Conference for Protective Relay Engineers, 2010, p.1-23</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5469503$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2056,27923,54918</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5469503$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Scharlach, Rogerio C</creatorcontrib><creatorcontrib>Young, Jason</creatorcontrib><title>Lessons learned from generator event reports</title><title>2010 63rd Annual Conference for Protective Relay Engineers</title><addtitle>CPRE</addtitle><description>Generators are critical components of the power system. In addition to being some of the most expensive pieces of equipment on the system, they are also extremely critical to power system stability. A false trip can lead to extensive testing in search of a nonexistent fault, while a delayed trip can result in unnecessary additional damage to equipment. Both misoperations result in excessive equipment outages, increasing the utility's outage costs and placing additional strain on the system. Therefore, the misoperation of protective relay schemes at generating stations is very expensive and must be avoided. This paper analyzes real-world event report data in the interest of uncovering valuable lessons for setting and commissioning generator relays. The paper reviews the application of phase differential relays for protection of the generator stator windings against phase faults and the application of third-harmonic voltage elements for 100 percent stator ground protection. Additionally, the effects of negative-sequence currents and overexcitation on a generator are discussed, as well as the importance of detecting and removing both conditions. With event report data, the paper teaches important lessons to be used in applying each function to protect generators. The paper discusses application limitations and considerations for each case.</description><subject>Capacitive sensors</subject><subject>Costs</subject><subject>Delay</subject><subject>Power generation</subject><subject>Power system faults</subject><subject>Power system stability</subject><subject>Protection</subject><subject>Protective relaying</subject><subject>Stator windings</subject><subject>Testing</subject><isbn>9781424460731</isbn><isbn>1424460735</isbn><isbn>9781424460748</isbn><isbn>1424460743</isbn><isbn>9781424460755</isbn><isbn>1424460751</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2010</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNpVj81KAzEUhSMiKHUeQNzkAZyam9z8LWWoVhiwlO5LOrmRkXamJIPg2ztgN57N4YOPA4exBxBLAOGfm812tZRiRo3Ga6GuWOWtA5SIRlh01_9YwS2rSvkSc1BL9OaOPbVUyjgUfqSQB4o85fHEP2mgHKYxc_qmYeKZzmOeyj27SeFYqLr0gu1eV7tmXbcfb-_NS1v3Xkx1pyCk4Lskk0OVbDSafCKMgGC1NBC1jtFYDJ066FmVrjsQuUTRUgxCLdjj32xPRPtz7k8h_-wvF9UvFlhFPQ</recordid><startdate>201003</startdate><enddate>201003</enddate><creator>Scharlach, Rogerio C</creator><creator>Young, Jason</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201003</creationdate><title>Lessons learned from generator event reports</title><author>Scharlach, Rogerio C ; Young, Jason</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-c31afa9cf2f843f7d65e9fe4d14175261d55dd674ac3b5afa28cbee8fed7eda03</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Capacitive sensors</topic><topic>Costs</topic><topic>Delay</topic><topic>Power generation</topic><topic>Power system faults</topic><topic>Power system stability</topic><topic>Protection</topic><topic>Protective relaying</topic><topic>Stator windings</topic><topic>Testing</topic><toplevel>online_resources</toplevel><creatorcontrib>Scharlach, Rogerio C</creatorcontrib><creatorcontrib>Young, Jason</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Scharlach, Rogerio C</au><au>Young, Jason</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Lessons learned from generator event reports</atitle><btitle>2010 63rd Annual Conference for Protective Relay Engineers</btitle><stitle>CPRE</stitle><date>2010-03</date><risdate>2010</risdate><spage>1</spage><epage>23</epage><pages>1-23</pages><isbn>9781424460731</isbn><isbn>1424460735</isbn><eisbn>9781424460748</eisbn><eisbn>1424460743</eisbn><eisbn>9781424460755</eisbn><eisbn>1424460751</eisbn><abstract>Generators are critical components of the power system. In addition to being some of the most expensive pieces of equipment on the system, they are also extremely critical to power system stability. A false trip can lead to extensive testing in search of a nonexistent fault, while a delayed trip can result in unnecessary additional damage to equipment. Both misoperations result in excessive equipment outages, increasing the utility's outage costs and placing additional strain on the system. Therefore, the misoperation of protective relay schemes at generating stations is very expensive and must be avoided. This paper analyzes real-world event report data in the interest of uncovering valuable lessons for setting and commissioning generator relays. The paper reviews the application of phase differential relays for protection of the generator stator windings against phase faults and the application of third-harmonic voltage elements for 100 percent stator ground protection. Additionally, the effects of negative-sequence currents and overexcitation on a generator are discussed, as well as the importance of detecting and removing both conditions. With event report data, the paper teaches important lessons to be used in applying each function to protect generators. The paper discusses application limitations and considerations for each case.</abstract><pub>IEEE</pub><doi>10.1109/CPRE.2010.5469503</doi><tpages>23</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 9781424460731
ispartof 2010 63rd Annual Conference for Protective Relay Engineers, 2010, p.1-23
issn
language eng
recordid cdi_ieee_primary_5469503
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Capacitive sensors
Costs
Delay
Power generation
Power system faults
Power system stability
Protection
Protective relaying
Stator windings
Testing
title Lessons learned from generator event reports
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T13%3A48%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Lessons%20learned%20from%20generator%20event%20reports&rft.btitle=2010%2063rd%20Annual%20Conference%20for%20Protective%20Relay%20Engineers&rft.au=Scharlach,%20Rogerio%20C&rft.date=2010-03&rft.spage=1&rft.epage=23&rft.pages=1-23&rft.isbn=9781424460731&rft.isbn_list=1424460735&rft_id=info:doi/10.1109/CPRE.2010.5469503&rft_dat=%3Cieee_6IE%3E5469503%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781424460748&rft.eisbn_list=1424460743&rft.eisbn_list=9781424460755&rft.eisbn_list=1424460751&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=5469503&rfr_iscdi=true