Control of an inverter output active du/dt filtering method
Frequency converters are used to increase the controllability and efficiency of electric motor drives. Induction motors may experience an insulation failure caused by an overvoltage at the motor terminals. The overvoltage is caused by an impedance mismatch between the motor terminals and the motor c...
Gespeichert in:
Hauptverfasser: | , , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Frequency converters are used to increase the controllability and efficiency of electric motor drives. Induction motors may experience an insulation failure caused by an overvoltage at the motor terminals. The overvoltage is caused by an impedance mismatch between the motor terminals and the motor cable. Fast pulse rise times compared with the propagation delay in the motor cable will make the terminal voltage exceed the DC link voltage level. Passive filtering techniques for two-level inverters have been developed to cancel out the overvoltage. In this paper, a control method for active du/dt filtering to reduce motor terminal overvoltage is introduced. A filter topology and the basis for setting the filter component values are presented. The size of the passive filter used in this filtering method is smaller than in traditional passive du/dt filters. Functional filtering can be achieved with a smaller filter by controlling the filter output voltage rise time with an accurately timed inverter output voltage. The control of the system is implemented on a field programmable gate array (FPGA) to provide precise gate drive signals with high time resolution. |
---|---|
ISSN: | 1553-572X |
DOI: | 10.1109/IECON.2009.5414941 |