Simple fiber Bragg grating sensing systems for structural health monitoring

This paper reviews a couple of simple and low-cost techniques suitable to interrogate the fiber Bragg grating sensors used in structural health monitoring and provides few examples on their applications. Both these techniques evaluate mechanical strains through the measurement of optical power varia...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Tosi, D., Olivero, M., Perrone, G., Vallan, A., Arcudi, L.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 86
container_issue
container_start_page 80
container_title
container_volume
creator Tosi, D.
Olivero, M.
Perrone, G.
Vallan, A.
Arcudi, L.
description This paper reviews a couple of simple and low-cost techniques suitable to interrogate the fiber Bragg grating sensors used in structural health monitoring and provides few examples on their applications. Both these techniques evaluate mechanical strains through the measurement of optical power variations, thus avoiding expensive spectral analyses. With the first technique, which uses a broadband source and a pair of matched gratings, it is possible to fabricate a low-cost optical sensor with intrinsic compensation for temperature effects. The other technique, which is based on a laser source wavelength-matched with the Bragg grating, allows evaluating dynamic strains down to few nanostrain. These two complementary approaches are analyzed and compared, highlighting their strengths and weakness from the point of view of structural health monitoring applications. Then, since interrogation methods that exploit the variation of the received signal amplitude are very sensitive to noise, a description of how performances can be improved using standard signal-processing algorithms is also given. The combination of one of the proposed approaches with the suitable signal-processing techniques allows achieving results comparable with other common grating interrogation methods, but at a fraction of their costs.
doi_str_mv 10.1109/EESMS.2009.5341310
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_5341310</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5341310</ieee_id><sourcerecordid>5341310</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-ef77c1cea9c0a850e699b9f307703cef7010b18cae8406425961eb91450f649f3</originalsourceid><addsrcrecordid>eNo1kMtOwzAQRY1QJWjJD8DGP5AwTvyIl1CFgihike4rJxqnRnlUtrvo3xOgzCyOru7RLIaQewYZY6Afq6r-qLMcQGei4KxgcEWWjOec83Lea5JoVf5nBQuy_HE1CMnlDUlC-IJ5uMhLXtyS99oNxx6pdQ16-uxN19HOm-jGjgYcwy_PIeIQqJ08DdGf2njypqcHNH080GEaXZz8LN6RhTV9wOTCFdm9VLv1a7r93Lytn7ap0xBTtEq1rEWjWzClAJRaN9oWoBQU7dwCg4aVrcGSg-S50JJhoxkXYCWfxRV5-DvrEHF_9G4w_ry__KL4BnqKUO4</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Simple fiber Bragg grating sensing systems for structural health monitoring</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Tosi, D. ; Olivero, M. ; Perrone, G. ; Vallan, A. ; Arcudi, L.</creator><creatorcontrib>Tosi, D. ; Olivero, M. ; Perrone, G. ; Vallan, A. ; Arcudi, L.</creatorcontrib><description>This paper reviews a couple of simple and low-cost techniques suitable to interrogate the fiber Bragg grating sensors used in structural health monitoring and provides few examples on their applications. Both these techniques evaluate mechanical strains through the measurement of optical power variations, thus avoiding expensive spectral analyses. With the first technique, which uses a broadband source and a pair of matched gratings, it is possible to fabricate a low-cost optical sensor with intrinsic compensation for temperature effects. The other technique, which is based on a laser source wavelength-matched with the Bragg grating, allows evaluating dynamic strains down to few nanostrain. These two complementary approaches are analyzed and compared, highlighting their strengths and weakness from the point of view of structural health monitoring applications. Then, since interrogation methods that exploit the variation of the received signal amplitude are very sensitive to noise, a description of how performances can be improved using standard signal-processing algorithms is also given. The combination of one of the proposed approaches with the suitable signal-processing techniques allows achieving results comparable with other common grating interrogation methods, but at a fraction of their costs.</description><identifier>ISBN: 9781424448470</identifier><identifier>ISBN: 1424448476</identifier><identifier>EISBN: 1424448484</identifier><identifier>EISBN: 9781424448487</identifier><identifier>DOI: 10.1109/EESMS.2009.5341310</identifier><identifier>LCCN: 2009905646</identifier><language>eng</language><publisher>IEEE</publisher><subject>Fiber Bragg Grating (FBG) ; Fiber Optic Sensors (FOS) ; Gratings ; Mechanical sensors ; Mechanical variables measurement ; Monitoring ; Optical Fiber Transducers ; Optical sensors ; Power measurement ; Spectral analysis ; Strain measurement ; Structural Monitoring ; Temperature sensors ; Wavelength measurement</subject><ispartof>2009 IEEE Workshop on Environmental, Energy, and Structural Monitoring Systems, 2009, p.80-86</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5341310$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2056,27916,54911</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5341310$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Tosi, D.</creatorcontrib><creatorcontrib>Olivero, M.</creatorcontrib><creatorcontrib>Perrone, G.</creatorcontrib><creatorcontrib>Vallan, A.</creatorcontrib><creatorcontrib>Arcudi, L.</creatorcontrib><title>Simple fiber Bragg grating sensing systems for structural health monitoring</title><title>2009 IEEE Workshop on Environmental, Energy, and Structural Monitoring Systems</title><addtitle>EESMS</addtitle><description>This paper reviews a couple of simple and low-cost techniques suitable to interrogate the fiber Bragg grating sensors used in structural health monitoring and provides few examples on their applications. Both these techniques evaluate mechanical strains through the measurement of optical power variations, thus avoiding expensive spectral analyses. With the first technique, which uses a broadband source and a pair of matched gratings, it is possible to fabricate a low-cost optical sensor with intrinsic compensation for temperature effects. The other technique, which is based on a laser source wavelength-matched with the Bragg grating, allows evaluating dynamic strains down to few nanostrain. These two complementary approaches are analyzed and compared, highlighting their strengths and weakness from the point of view of structural health monitoring applications. Then, since interrogation methods that exploit the variation of the received signal amplitude are very sensitive to noise, a description of how performances can be improved using standard signal-processing algorithms is also given. The combination of one of the proposed approaches with the suitable signal-processing techniques allows achieving results comparable with other common grating interrogation methods, but at a fraction of their costs.</description><subject>Fiber Bragg Grating (FBG)</subject><subject>Fiber Optic Sensors (FOS)</subject><subject>Gratings</subject><subject>Mechanical sensors</subject><subject>Mechanical variables measurement</subject><subject>Monitoring</subject><subject>Optical Fiber Transducers</subject><subject>Optical sensors</subject><subject>Power measurement</subject><subject>Spectral analysis</subject><subject>Strain measurement</subject><subject>Structural Monitoring</subject><subject>Temperature sensors</subject><subject>Wavelength measurement</subject><isbn>9781424448470</isbn><isbn>1424448476</isbn><isbn>1424448484</isbn><isbn>9781424448487</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2009</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo1kMtOwzAQRY1QJWjJD8DGP5AwTvyIl1CFgihike4rJxqnRnlUtrvo3xOgzCyOru7RLIaQewYZY6Afq6r-qLMcQGei4KxgcEWWjOec83Lea5JoVf5nBQuy_HE1CMnlDUlC-IJ5uMhLXtyS99oNxx6pdQ16-uxN19HOm-jGjgYcwy_PIeIQqJ08DdGf2njypqcHNH080GEaXZz8LN6RhTV9wOTCFdm9VLv1a7r93Lytn7ap0xBTtEq1rEWjWzClAJRaN9oWoBQU7dwCg4aVrcGSg-S50JJhoxkXYCWfxRV5-DvrEHF_9G4w_ry__KL4BnqKUO4</recordid><startdate>200909</startdate><enddate>200909</enddate><creator>Tosi, D.</creator><creator>Olivero, M.</creator><creator>Perrone, G.</creator><creator>Vallan, A.</creator><creator>Arcudi, L.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>200909</creationdate><title>Simple fiber Bragg grating sensing systems for structural health monitoring</title><author>Tosi, D. ; Olivero, M. ; Perrone, G. ; Vallan, A. ; Arcudi, L.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-ef77c1cea9c0a850e699b9f307703cef7010b18cae8406425961eb91450f649f3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Fiber Bragg Grating (FBG)</topic><topic>Fiber Optic Sensors (FOS)</topic><topic>Gratings</topic><topic>Mechanical sensors</topic><topic>Mechanical variables measurement</topic><topic>Monitoring</topic><topic>Optical Fiber Transducers</topic><topic>Optical sensors</topic><topic>Power measurement</topic><topic>Spectral analysis</topic><topic>Strain measurement</topic><topic>Structural Monitoring</topic><topic>Temperature sensors</topic><topic>Wavelength measurement</topic><toplevel>online_resources</toplevel><creatorcontrib>Tosi, D.</creatorcontrib><creatorcontrib>Olivero, M.</creatorcontrib><creatorcontrib>Perrone, G.</creatorcontrib><creatorcontrib>Vallan, A.</creatorcontrib><creatorcontrib>Arcudi, L.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Tosi, D.</au><au>Olivero, M.</au><au>Perrone, G.</au><au>Vallan, A.</au><au>Arcudi, L.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Simple fiber Bragg grating sensing systems for structural health monitoring</atitle><btitle>2009 IEEE Workshop on Environmental, Energy, and Structural Monitoring Systems</btitle><stitle>EESMS</stitle><date>2009-09</date><risdate>2009</risdate><spage>80</spage><epage>86</epage><pages>80-86</pages><isbn>9781424448470</isbn><isbn>1424448476</isbn><eisbn>1424448484</eisbn><eisbn>9781424448487</eisbn><abstract>This paper reviews a couple of simple and low-cost techniques suitable to interrogate the fiber Bragg grating sensors used in structural health monitoring and provides few examples on their applications. Both these techniques evaluate mechanical strains through the measurement of optical power variations, thus avoiding expensive spectral analyses. With the first technique, which uses a broadband source and a pair of matched gratings, it is possible to fabricate a low-cost optical sensor with intrinsic compensation for temperature effects. The other technique, which is based on a laser source wavelength-matched with the Bragg grating, allows evaluating dynamic strains down to few nanostrain. These two complementary approaches are analyzed and compared, highlighting their strengths and weakness from the point of view of structural health monitoring applications. Then, since interrogation methods that exploit the variation of the received signal amplitude are very sensitive to noise, a description of how performances can be improved using standard signal-processing algorithms is also given. The combination of one of the proposed approaches with the suitable signal-processing techniques allows achieving results comparable with other common grating interrogation methods, but at a fraction of their costs.</abstract><pub>IEEE</pub><doi>10.1109/EESMS.2009.5341310</doi><tpages>7</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 9781424448470
ispartof 2009 IEEE Workshop on Environmental, Energy, and Structural Monitoring Systems, 2009, p.80-86
issn
language eng
recordid cdi_ieee_primary_5341310
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Fiber Bragg Grating (FBG)
Fiber Optic Sensors (FOS)
Gratings
Mechanical sensors
Mechanical variables measurement
Monitoring
Optical Fiber Transducers
Optical sensors
Power measurement
Spectral analysis
Strain measurement
Structural Monitoring
Temperature sensors
Wavelength measurement
title Simple fiber Bragg grating sensing systems for structural health monitoring
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T23%3A46%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Simple%20fiber%20Bragg%20grating%20sensing%20systems%20for%20structural%20health%20monitoring&rft.btitle=2009%20IEEE%20Workshop%20on%20Environmental,%20Energy,%20and%20Structural%20Monitoring%20Systems&rft.au=Tosi,%20D.&rft.date=2009-09&rft.spage=80&rft.epage=86&rft.pages=80-86&rft.isbn=9781424448470&rft.isbn_list=1424448476&rft_id=info:doi/10.1109/EESMS.2009.5341310&rft_dat=%3Cieee_6IE%3E5341310%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1424448484&rft.eisbn_list=9781424448487&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=5341310&rfr_iscdi=true