New method of live line measuring the parameters of t-connection transmission lines with mutual inductance

Based on GPS technology, a novel method of live line measuring the zero sequence parameters of T-connection transmission lines with mutual inductance is proposed. The mathematical models of the new method are explained in detail. The hardware structure and digital simulation results are given. Final...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Zhijian Hu, Jiacheng Fan, Mi Chen, Zhongzhu Xu
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 5
container_issue
container_start_page 1
container_title
container_volume
creator Zhijian Hu
Jiacheng Fan
Mi Chen
Zhongzhu Xu
description Based on GPS technology, a novel method of live line measuring the zero sequence parameters of T-connection transmission lines with mutual inductance is proposed. The mathematical models of the new method are explained in detail. The hardware structure and digital simulation results are given. Finally, an example of live line measuring two 220kV transmission lines with T-connection branches in South China power grid is given. The field measurement results prove that the new method can meet the needs of live line measurement of T-connection transmission lines' inductance parameters.
doi_str_mv 10.1109/PES.2009.5275297
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_5275297</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5275297</ieee_id><sourcerecordid>5275297</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-c90beeee4bd2bb418dc5c5ddda1e5bfe3bd75be75cc4ea35b05ce30ac2801e6b3</originalsourceid><addsrcrecordid>eNotkE1LAzEQhgMqWGvvgpf8gV3zsWk2RynVCkUFey_5mHVTdrNlk7X4702xAzMvM_POcxiEHigpKSXq6XP9VTJCVCmYFEzJK7RQsqYVq6qcdHmNZlRxVghB5S26i_FAiOB5P0OHdzjhHlI7ODw0uPM_kEuAPNNxGn34xqkFfNSjzi4Y49mVCjuEADb5IeA06hB7H-O5OZ9GfPKpxf2UJt1hH9xkkw4W7tFNo7sIi4vO0e5lvVttiu3H69vqeVt4RTJZEQM5KuOYMRWtnRVWOOc0BWEa4MZJYUAKayvQXBgiLHCiLasJhaXhc_T4j_WZsj-Ovtfj7_7yGf4H1Q9bhA</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>New method of live line measuring the parameters of t-connection transmission lines with mutual inductance</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Zhijian Hu ; Jiacheng Fan ; Mi Chen ; Zhongzhu Xu</creator><creatorcontrib>Zhijian Hu ; Jiacheng Fan ; Mi Chen ; Zhongzhu Xu</creatorcontrib><description>Based on GPS technology, a novel method of live line measuring the zero sequence parameters of T-connection transmission lines with mutual inductance is proposed. The mathematical models of the new method are explained in detail. The hardware structure and digital simulation results are given. Finally, an example of live line measuring two 220kV transmission lines with T-connection branches in South China power grid is given. The field measurement results prove that the new method can meet the needs of live line measurement of T-connection transmission lines' inductance parameters.</description><identifier>ISSN: 1932-5517</identifier><identifier>ISBN: 9781424442416</identifier><identifier>ISBN: 1424442419</identifier><identifier>DOI: 10.1109/PES.2009.5275297</identifier><language>eng</language><publisher>IEEE</publisher><subject>Earth ; Global Positioning System ; Inductance measurement ; live line measurement ; Mathematical model ; Position measurement ; Power system protection ; Power system relaying ; Power system reliability ; Power transmission lines ; T-connection transmission lines ; Transmission line measurements ; zero sequence parameters</subject><ispartof>2009 IEEE Power &amp; Energy Society General Meeting, 2009, p.1-5</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5275297$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>310,311,781,785,790,791,2059,27929,54924</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5275297$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Zhijian Hu</creatorcontrib><creatorcontrib>Jiacheng Fan</creatorcontrib><creatorcontrib>Mi Chen</creatorcontrib><creatorcontrib>Zhongzhu Xu</creatorcontrib><title>New method of live line measuring the parameters of t-connection transmission lines with mutual inductance</title><title>2009 IEEE Power &amp; Energy Society General Meeting</title><addtitle>PES</addtitle><description>Based on GPS technology, a novel method of live line measuring the zero sequence parameters of T-connection transmission lines with mutual inductance is proposed. The mathematical models of the new method are explained in detail. The hardware structure and digital simulation results are given. Finally, an example of live line measuring two 220kV transmission lines with T-connection branches in South China power grid is given. The field measurement results prove that the new method can meet the needs of live line measurement of T-connection transmission lines' inductance parameters.</description><subject>Earth</subject><subject>Global Positioning System</subject><subject>Inductance measurement</subject><subject>live line measurement</subject><subject>Mathematical model</subject><subject>Position measurement</subject><subject>Power system protection</subject><subject>Power system relaying</subject><subject>Power system reliability</subject><subject>Power transmission lines</subject><subject>T-connection transmission lines</subject><subject>Transmission line measurements</subject><subject>zero sequence parameters</subject><issn>1932-5517</issn><isbn>9781424442416</isbn><isbn>1424442419</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2009</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotkE1LAzEQhgMqWGvvgpf8gV3zsWk2RynVCkUFey_5mHVTdrNlk7X4702xAzMvM_POcxiEHigpKSXq6XP9VTJCVCmYFEzJK7RQsqYVq6qcdHmNZlRxVghB5S26i_FAiOB5P0OHdzjhHlI7ODw0uPM_kEuAPNNxGn34xqkFfNSjzi4Y49mVCjuEADb5IeA06hB7H-O5OZ9GfPKpxf2UJt1hH9xkkw4W7tFNo7sIi4vO0e5lvVttiu3H69vqeVt4RTJZEQM5KuOYMRWtnRVWOOc0BWEa4MZJYUAKayvQXBgiLHCiLasJhaXhc_T4j_WZsj-Ovtfj7_7yGf4H1Q9bhA</recordid><startdate>200907</startdate><enddate>200907</enddate><creator>Zhijian Hu</creator><creator>Jiacheng Fan</creator><creator>Mi Chen</creator><creator>Zhongzhu Xu</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>200907</creationdate><title>New method of live line measuring the parameters of t-connection transmission lines with mutual inductance</title><author>Zhijian Hu ; Jiacheng Fan ; Mi Chen ; Zhongzhu Xu</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-c90beeee4bd2bb418dc5c5ddda1e5bfe3bd75be75cc4ea35b05ce30ac2801e6b3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Earth</topic><topic>Global Positioning System</topic><topic>Inductance measurement</topic><topic>live line measurement</topic><topic>Mathematical model</topic><topic>Position measurement</topic><topic>Power system protection</topic><topic>Power system relaying</topic><topic>Power system reliability</topic><topic>Power transmission lines</topic><topic>T-connection transmission lines</topic><topic>Transmission line measurements</topic><topic>zero sequence parameters</topic><toplevel>online_resources</toplevel><creatorcontrib>Zhijian Hu</creatorcontrib><creatorcontrib>Jiacheng Fan</creatorcontrib><creatorcontrib>Mi Chen</creatorcontrib><creatorcontrib>Zhongzhu Xu</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Zhijian Hu</au><au>Jiacheng Fan</au><au>Mi Chen</au><au>Zhongzhu Xu</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>New method of live line measuring the parameters of t-connection transmission lines with mutual inductance</atitle><btitle>2009 IEEE Power &amp; Energy Society General Meeting</btitle><stitle>PES</stitle><date>2009-07</date><risdate>2009</risdate><spage>1</spage><epage>5</epage><pages>1-5</pages><issn>1932-5517</issn><isbn>9781424442416</isbn><isbn>1424442419</isbn><abstract>Based on GPS technology, a novel method of live line measuring the zero sequence parameters of T-connection transmission lines with mutual inductance is proposed. The mathematical models of the new method are explained in detail. The hardware structure and digital simulation results are given. Finally, an example of live line measuring two 220kV transmission lines with T-connection branches in South China power grid is given. The field measurement results prove that the new method can meet the needs of live line measurement of T-connection transmission lines' inductance parameters.</abstract><pub>IEEE</pub><doi>10.1109/PES.2009.5275297</doi><tpages>5</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1932-5517
ispartof 2009 IEEE Power & Energy Society General Meeting, 2009, p.1-5
issn 1932-5517
language eng
recordid cdi_ieee_primary_5275297
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Earth
Global Positioning System
Inductance measurement
live line measurement
Mathematical model
Position measurement
Power system protection
Power system relaying
Power system reliability
Power transmission lines
T-connection transmission lines
Transmission line measurements
zero sequence parameters
title New method of live line measuring the parameters of t-connection transmission lines with mutual inductance
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-17T07%3A19%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=New%20method%20of%20live%20line%20measuring%20the%20parameters%20of%20t-connection%20transmission%20lines%20with%20mutual%20inductance&rft.btitle=2009%20IEEE%20Power%20&%20Energy%20Society%20General%20Meeting&rft.au=Zhijian%20Hu&rft.date=2009-07&rft.spage=1&rft.epage=5&rft.pages=1-5&rft.issn=1932-5517&rft.isbn=9781424442416&rft.isbn_list=1424442419&rft_id=info:doi/10.1109/PES.2009.5275297&rft_dat=%3Cieee_6IE%3E5275297%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=5275297&rfr_iscdi=true