The Research of Radiotherapy Treatment Planning System Based on CT Image

Radiotherapy is a very important tumor treatment. And cobalt-60 radiotherapy machine (also known as gamma knife) is a common external beam radiotherapy equipment and is designed mainly for conventional radiotherapy. We develop a software system, which is named radiotherapy treatment planning system,...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Wu, Junsheng, Chen, Hongchu, Li, Yong
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 4
container_issue
container_start_page 1
container_title
container_volume
creator Wu, Junsheng
Chen, Hongchu
Li, Yong
description Radiotherapy is a very important tumor treatment. And cobalt-60 radiotherapy machine (also known as gamma knife) is a common external beam radiotherapy equipment and is designed mainly for conventional radiotherapy. We develop a software system, which is named radiotherapy treatment planning system, to make gamma knife more precise in radiotherapy. Section II introduces the principle of gamma knife the system works with. Section III expounds the main components of system. It is composed of image pre-processing, dose computation, dose distribution display, three-dimensional reconstruction, and other modules. Section III.B introduces TMR-OAR model the system uses to compute dose distribution. And Section III.D introduces the way of human body data and dose data visualization. Finally, Section III.E shows the evaluation consequence of a treatment plan. The system works well, and achieves the expected results.
doi_str_mv 10.1109/ICBBE.2009.5163652
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_5163652</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5163652</ieee_id><sourcerecordid>5163652</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-e31fd4d90c2c3873cc0b6c8eb4f2f726fadba5585c95a9b0f284e35e5119c7e23</originalsourceid><addsrcrecordid>eNo9kL1uwjAURt0fpALlBdrFL5DU99pO7LFEtERCakWzI8e5hlQkQUkW3r5Ipf2WMxzpDB9jTyBiAGFf8my5XMUohI01JDLReMNmoFAptALhlk0RNERpgnjHFjY1fw7g_t-BmrDZpWGs1AbtA1sMw7e4TGm0Sk_ZujgQ39JArvcH3gW-dVXdjQfq3enMi57c2FA78s-ja9u63fOv8zBSw5duoIp3Lc8KnjduT49sEtxxoMWVc1a8rYpsHW0-3vPsdRPVVowRSQiVqqzw6KVJpfeiTLyhUgUMKSbBVaXT2mhvtbOlCGgUSU0awPqUUM7Z82-2JqLdqa8b159314PkD9v3UoI</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>The Research of Radiotherapy Treatment Planning System Based on CT Image</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Wu, Junsheng ; Chen, Hongchu ; Li, Yong</creator><creatorcontrib>Wu, Junsheng ; Chen, Hongchu ; Li, Yong</creatorcontrib><description>Radiotherapy is a very important tumor treatment. And cobalt-60 radiotherapy machine (also known as gamma knife) is a common external beam radiotherapy equipment and is designed mainly for conventional radiotherapy. We develop a software system, which is named radiotherapy treatment planning system, to make gamma knife more precise in radiotherapy. Section II introduces the principle of gamma knife the system works with. Section III expounds the main components of system. It is composed of image pre-processing, dose computation, dose distribution display, three-dimensional reconstruction, and other modules. Section III.B introduces TMR-OAR model the system uses to compute dose distribution. And Section III.D introduces the way of human body data and dose data visualization. Finally, Section III.E shows the evaluation consequence of a treatment plan. The system works well, and achieves the expected results.</description><identifier>ISSN: 2151-7614</identifier><identifier>ISBN: 9781424429011</identifier><identifier>ISBN: 1424429013</identifier><identifier>EISSN: 2151-7622</identifier><identifier>EISBN: 1424429021</identifier><identifier>EISBN: 9781424429028</identifier><identifier>DOI: 10.1109/ICBBE.2009.5163652</identifier><identifier>LCCN: 2008935829</identifier><language>eng</language><publisher>IEEE</publisher><subject>Biological system modeling ; Computed tomography ; Computer displays ; Data visualization ; Distributed computing ; Humans ; Image reconstruction ; Neoplasms ; Software systems ; Three dimensional displays</subject><ispartof>2009 3rd International Conference on Bioinformatics and Biomedical Engineering, 2009, p.1-4</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5163652$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2051,27904,54899</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5163652$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Wu, Junsheng</creatorcontrib><creatorcontrib>Chen, Hongchu</creatorcontrib><creatorcontrib>Li, Yong</creatorcontrib><title>The Research of Radiotherapy Treatment Planning System Based on CT Image</title><title>2009 3rd International Conference on Bioinformatics and Biomedical Engineering</title><addtitle>ICBBE</addtitle><description>Radiotherapy is a very important tumor treatment. And cobalt-60 radiotherapy machine (also known as gamma knife) is a common external beam radiotherapy equipment and is designed mainly for conventional radiotherapy. We develop a software system, which is named radiotherapy treatment planning system, to make gamma knife more precise in radiotherapy. Section II introduces the principle of gamma knife the system works with. Section III expounds the main components of system. It is composed of image pre-processing, dose computation, dose distribution display, three-dimensional reconstruction, and other modules. Section III.B introduces TMR-OAR model the system uses to compute dose distribution. And Section III.D introduces the way of human body data and dose data visualization. Finally, Section III.E shows the evaluation consequence of a treatment plan. The system works well, and achieves the expected results.</description><subject>Biological system modeling</subject><subject>Computed tomography</subject><subject>Computer displays</subject><subject>Data visualization</subject><subject>Distributed computing</subject><subject>Humans</subject><subject>Image reconstruction</subject><subject>Neoplasms</subject><subject>Software systems</subject><subject>Three dimensional displays</subject><issn>2151-7614</issn><issn>2151-7622</issn><isbn>9781424429011</isbn><isbn>1424429013</isbn><isbn>1424429021</isbn><isbn>9781424429028</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2009</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo9kL1uwjAURt0fpALlBdrFL5DU99pO7LFEtERCakWzI8e5hlQkQUkW3r5Ipf2WMxzpDB9jTyBiAGFf8my5XMUohI01JDLReMNmoFAptALhlk0RNERpgnjHFjY1fw7g_t-BmrDZpWGs1AbtA1sMw7e4TGm0Sk_ZujgQ39JArvcH3gW-dVXdjQfq3enMi57c2FA78s-ja9u63fOv8zBSw5duoIp3Lc8KnjduT49sEtxxoMWVc1a8rYpsHW0-3vPsdRPVVowRSQiVqqzw6KVJpfeiTLyhUgUMKSbBVaXT2mhvtbOlCGgUSU0awPqUUM7Z82-2JqLdqa8b159314PkD9v3UoI</recordid><startdate>200906</startdate><enddate>200906</enddate><creator>Wu, Junsheng</creator><creator>Chen, Hongchu</creator><creator>Li, Yong</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>200906</creationdate><title>The Research of Radiotherapy Treatment Planning System Based on CT Image</title><author>Wu, Junsheng ; Chen, Hongchu ; Li, Yong</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-e31fd4d90c2c3873cc0b6c8eb4f2f726fadba5585c95a9b0f284e35e5119c7e23</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Biological system modeling</topic><topic>Computed tomography</topic><topic>Computer displays</topic><topic>Data visualization</topic><topic>Distributed computing</topic><topic>Humans</topic><topic>Image reconstruction</topic><topic>Neoplasms</topic><topic>Software systems</topic><topic>Three dimensional displays</topic><toplevel>online_resources</toplevel><creatorcontrib>Wu, Junsheng</creatorcontrib><creatorcontrib>Chen, Hongchu</creatorcontrib><creatorcontrib>Li, Yong</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Wu, Junsheng</au><au>Chen, Hongchu</au><au>Li, Yong</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>The Research of Radiotherapy Treatment Planning System Based on CT Image</atitle><btitle>2009 3rd International Conference on Bioinformatics and Biomedical Engineering</btitle><stitle>ICBBE</stitle><date>2009-06</date><risdate>2009</risdate><spage>1</spage><epage>4</epage><pages>1-4</pages><issn>2151-7614</issn><eissn>2151-7622</eissn><isbn>9781424429011</isbn><isbn>1424429013</isbn><eisbn>1424429021</eisbn><eisbn>9781424429028</eisbn><abstract>Radiotherapy is a very important tumor treatment. And cobalt-60 radiotherapy machine (also known as gamma knife) is a common external beam radiotherapy equipment and is designed mainly for conventional radiotherapy. We develop a software system, which is named radiotherapy treatment planning system, to make gamma knife more precise in radiotherapy. Section II introduces the principle of gamma knife the system works with. Section III expounds the main components of system. It is composed of image pre-processing, dose computation, dose distribution display, three-dimensional reconstruction, and other modules. Section III.B introduces TMR-OAR model the system uses to compute dose distribution. And Section III.D introduces the way of human body data and dose data visualization. Finally, Section III.E shows the evaluation consequence of a treatment plan. The system works well, and achieves the expected results.</abstract><pub>IEEE</pub><doi>10.1109/ICBBE.2009.5163652</doi><tpages>4</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 2151-7614
ispartof 2009 3rd International Conference on Bioinformatics and Biomedical Engineering, 2009, p.1-4
issn 2151-7614
2151-7622
language eng
recordid cdi_ieee_primary_5163652
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Biological system modeling
Computed tomography
Computer displays
Data visualization
Distributed computing
Humans
Image reconstruction
Neoplasms
Software systems
Three dimensional displays
title The Research of Radiotherapy Treatment Planning System Based on CT Image
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-21T13%3A03%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=The%20Research%20of%20Radiotherapy%20Treatment%20Planning%20System%20Based%20on%20CT%20Image&rft.btitle=2009%203rd%20International%20Conference%20on%20Bioinformatics%20and%20Biomedical%20Engineering&rft.au=Wu,%20Junsheng&rft.date=2009-06&rft.spage=1&rft.epage=4&rft.pages=1-4&rft.issn=2151-7614&rft.eissn=2151-7622&rft.isbn=9781424429011&rft.isbn_list=1424429013&rft_id=info:doi/10.1109/ICBBE.2009.5163652&rft_dat=%3Cieee_6IE%3E5163652%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1424429021&rft.eisbn_list=9781424429028&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=5163652&rfr_iscdi=true