Experiments on Capacitive Current Interruption with Air-Break High Voltage Disconnectors
Capacitive current interruption with air-break disconnectors in a high-voltage network is an interactive event between circuit and arc with a variety of interruptions and re- ignitions. In order to investigate this transient phenomenon, a series of interruption tests was performed at KEMA High Power...
Gespeichert in:
Hauptverfasser: | , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 6 |
---|---|
container_issue | |
container_start_page | 1 |
container_title | |
container_volume | |
creator | Chai, Y. Wouters, P.A.A.F. Van Hoppe, R.T.W.J. Smeets, R.P.P. Peelo, D.F. |
description | Capacitive current interruption with air-break disconnectors in a high-voltage network is an interactive event between circuit and arc with a variety of interruptions and re- ignitions. In order to investigate this transient phenomenon, a series of interruption tests was performed at KEMA High Power Laboratory. In this paper, a brief analysis of the interruption process is presented and is compared with experimental data from the test. Typical wave shapes of voltages across the capacitances, disconnector and current through the disconnector are given. Re-ignition voltage and energy input to the arc on re- ignition are also investigated. Comparison shows that the test data are in good agreement with simulation. It is concluded that besides higher interruption current and higher power supply level, a lower ratio between source side and load side capacitance leads to more severe interruption and longer arc duration. In the end, the actual status of IEC recommendations on testing, that has taken into account this arc-circuit interaction, will be discussed. |
doi_str_mv | 10.1109/APPEEC.2009.4918366 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4918366</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4918366</ieee_id><sourcerecordid>4918366</sourcerecordid><originalsourceid>FETCH-LOGICAL-i1356-7d0f95a4d02f1e14de84b40815dbde6953946b0d742f043033cb591fa06f23b3</originalsourceid><addsrcrecordid>eNpFUF1rwkAQvNIKVesv8OX-QOzeZ3KPaRqrINQHKX2TS7LRa20SLmc__n0DFboMDLvDDMwSMmewYAzMfbrd5nm24ABmIQ1LhNZXZMIklwOS2Fz_LxpuyJgzFUcyEWZEJoMpMSA0M7dk1vdvMIxUPJbxmLzm3x1694FN6Gnb0Mx2tnTBfSLNzt4PZ7puAnp_7oIb9C8XjjR1PnrwaN_pyh2O9KU9BXtA-uj6sm0aLEPr-zsyqu2px9mFp2S3zHfZKto8P62zdBM5JpSO4gpqo6ysgNcMmawwkYWEhKmqqFAbJYzUBVSx5DVIAUKUhTKstqBrLgoxJfO_WIeI-25oYv3P_vIh8QveglZ5</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Experiments on Capacitive Current Interruption with Air-Break High Voltage Disconnectors</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Chai, Y. ; Wouters, P.A.A.F. ; Van Hoppe, R.T.W.J. ; Smeets, R.P.P. ; Peelo, D.F.</creator><creatorcontrib>Chai, Y. ; Wouters, P.A.A.F. ; Van Hoppe, R.T.W.J. ; Smeets, R.P.P. ; Peelo, D.F.</creatorcontrib><description>Capacitive current interruption with air-break disconnectors in a high-voltage network is an interactive event between circuit and arc with a variety of interruptions and re- ignitions. In order to investigate this transient phenomenon, a series of interruption tests was performed at KEMA High Power Laboratory. In this paper, a brief analysis of the interruption process is presented and is compared with experimental data from the test. Typical wave shapes of voltages across the capacitances, disconnector and current through the disconnector are given. Re-ignition voltage and energy input to the arc on re- ignition are also investigated. Comparison shows that the test data are in good agreement with simulation. It is concluded that besides higher interruption current and higher power supply level, a lower ratio between source side and load side capacitance leads to more severe interruption and longer arc duration. In the end, the actual status of IEC recommendations on testing, that has taken into account this arc-circuit interaction, will be discussed.</description><identifier>ISSN: 2157-4839</identifier><identifier>ISBN: 1424424860</identifier><identifier>ISBN: 9781424424863</identifier><identifier>EISBN: 1424424879</identifier><identifier>EISBN: 9781424424870</identifier><identifier>DOI: 10.1109/APPEEC.2009.4918366</identifier><identifier>LCCN: 2008903619</identifier><language>eng</language><publisher>IEEE</publisher><subject>Capacitance ; Circuit testing ; IEC ; Laboratories ; Performance evaluation ; Power supplies ; Shape ; Substations ; Switches ; Voltage</subject><ispartof>2009 Asia-Pacific Power and Energy Engineering Conference, 2009, p.1-6</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4918366$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4918366$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Chai, Y.</creatorcontrib><creatorcontrib>Wouters, P.A.A.F.</creatorcontrib><creatorcontrib>Van Hoppe, R.T.W.J.</creatorcontrib><creatorcontrib>Smeets, R.P.P.</creatorcontrib><creatorcontrib>Peelo, D.F.</creatorcontrib><title>Experiments on Capacitive Current Interruption with Air-Break High Voltage Disconnectors</title><title>2009 Asia-Pacific Power and Energy Engineering Conference</title><addtitle>APPEEC</addtitle><description>Capacitive current interruption with air-break disconnectors in a high-voltage network is an interactive event between circuit and arc with a variety of interruptions and re- ignitions. In order to investigate this transient phenomenon, a series of interruption tests was performed at KEMA High Power Laboratory. In this paper, a brief analysis of the interruption process is presented and is compared with experimental data from the test. Typical wave shapes of voltages across the capacitances, disconnector and current through the disconnector are given. Re-ignition voltage and energy input to the arc on re- ignition are also investigated. Comparison shows that the test data are in good agreement with simulation. It is concluded that besides higher interruption current and higher power supply level, a lower ratio between source side and load side capacitance leads to more severe interruption and longer arc duration. In the end, the actual status of IEC recommendations on testing, that has taken into account this arc-circuit interaction, will be discussed.</description><subject>Capacitance</subject><subject>Circuit testing</subject><subject>IEC</subject><subject>Laboratories</subject><subject>Performance evaluation</subject><subject>Power supplies</subject><subject>Shape</subject><subject>Substations</subject><subject>Switches</subject><subject>Voltage</subject><issn>2157-4839</issn><isbn>1424424860</isbn><isbn>9781424424863</isbn><isbn>1424424879</isbn><isbn>9781424424870</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2009</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNpFUF1rwkAQvNIKVesv8OX-QOzeZ3KPaRqrINQHKX2TS7LRa20SLmc__n0DFboMDLvDDMwSMmewYAzMfbrd5nm24ABmIQ1LhNZXZMIklwOS2Fz_LxpuyJgzFUcyEWZEJoMpMSA0M7dk1vdvMIxUPJbxmLzm3x1694FN6Gnb0Mx2tnTBfSLNzt4PZ7puAnp_7oIb9C8XjjR1PnrwaN_pyh2O9KU9BXtA-uj6sm0aLEPr-zsyqu2px9mFp2S3zHfZKto8P62zdBM5JpSO4gpqo6ysgNcMmawwkYWEhKmqqFAbJYzUBVSx5DVIAUKUhTKstqBrLgoxJfO_WIeI-25oYv3P_vIh8QveglZ5</recordid><startdate>200903</startdate><enddate>200903</enddate><creator>Chai, Y.</creator><creator>Wouters, P.A.A.F.</creator><creator>Van Hoppe, R.T.W.J.</creator><creator>Smeets, R.P.P.</creator><creator>Peelo, D.F.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>200903</creationdate><title>Experiments on Capacitive Current Interruption with Air-Break High Voltage Disconnectors</title><author>Chai, Y. ; Wouters, P.A.A.F. ; Van Hoppe, R.T.W.J. ; Smeets, R.P.P. ; Peelo, D.F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i1356-7d0f95a4d02f1e14de84b40815dbde6953946b0d742f043033cb591fa06f23b3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Capacitance</topic><topic>Circuit testing</topic><topic>IEC</topic><topic>Laboratories</topic><topic>Performance evaluation</topic><topic>Power supplies</topic><topic>Shape</topic><topic>Substations</topic><topic>Switches</topic><topic>Voltage</topic><toplevel>online_resources</toplevel><creatorcontrib>Chai, Y.</creatorcontrib><creatorcontrib>Wouters, P.A.A.F.</creatorcontrib><creatorcontrib>Van Hoppe, R.T.W.J.</creatorcontrib><creatorcontrib>Smeets, R.P.P.</creatorcontrib><creatorcontrib>Peelo, D.F.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Chai, Y.</au><au>Wouters, P.A.A.F.</au><au>Van Hoppe, R.T.W.J.</au><au>Smeets, R.P.P.</au><au>Peelo, D.F.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Experiments on Capacitive Current Interruption with Air-Break High Voltage Disconnectors</atitle><btitle>2009 Asia-Pacific Power and Energy Engineering Conference</btitle><stitle>APPEEC</stitle><date>2009-03</date><risdate>2009</risdate><spage>1</spage><epage>6</epage><pages>1-6</pages><issn>2157-4839</issn><isbn>1424424860</isbn><isbn>9781424424863</isbn><eisbn>1424424879</eisbn><eisbn>9781424424870</eisbn><abstract>Capacitive current interruption with air-break disconnectors in a high-voltage network is an interactive event between circuit and arc with a variety of interruptions and re- ignitions. In order to investigate this transient phenomenon, a series of interruption tests was performed at KEMA High Power Laboratory. In this paper, a brief analysis of the interruption process is presented and is compared with experimental data from the test. Typical wave shapes of voltages across the capacitances, disconnector and current through the disconnector are given. Re-ignition voltage and energy input to the arc on re- ignition are also investigated. Comparison shows that the test data are in good agreement with simulation. It is concluded that besides higher interruption current and higher power supply level, a lower ratio between source side and load side capacitance leads to more severe interruption and longer arc duration. In the end, the actual status of IEC recommendations on testing, that has taken into account this arc-circuit interaction, will be discussed.</abstract><pub>IEEE</pub><doi>10.1109/APPEEC.2009.4918366</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 2157-4839 |
ispartof | 2009 Asia-Pacific Power and Energy Engineering Conference, 2009, p.1-6 |
issn | 2157-4839 |
language | eng |
recordid | cdi_ieee_primary_4918366 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Capacitance Circuit testing IEC Laboratories Performance evaluation Power supplies Shape Substations Switches Voltage |
title | Experiments on Capacitive Current Interruption with Air-Break High Voltage Disconnectors |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T13%3A11%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Experiments%20on%20Capacitive%20Current%20Interruption%20with%20Air-Break%20High%20Voltage%20Disconnectors&rft.btitle=2009%20Asia-Pacific%20Power%20and%20Energy%20Engineering%20Conference&rft.au=Chai,%20Y.&rft.date=2009-03&rft.spage=1&rft.epage=6&rft.pages=1-6&rft.issn=2157-4839&rft.isbn=1424424860&rft.isbn_list=9781424424863&rft_id=info:doi/10.1109/APPEEC.2009.4918366&rft_dat=%3Cieee_6IE%3E4918366%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1424424879&rft.eisbn_list=9781424424870&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4918366&rfr_iscdi=true |