It is the premise for the diesel generator set to maintain the proper indoor environment of underground diesel generator plant. Based on the analysis and summarization of the characters of the heat and contaminant distribution in the underground generator plant, this paper proposes the ZGT (zonal gu...
Gespeichert in:
Hauptverfasser: | , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 221 |
---|---|
container_issue | |
container_start_page | 217 |
container_title | |
container_volume | |
creator | Xibin Ma Jinsheng Wang Baoyi Cheng Wenjie Liu Guanzhong Peng |
description | It is the premise for the diesel generator set to maintain the proper indoor environment of underground diesel generator plant. Based on the analysis and summarization of the characters of the heat and contaminant distribution in the underground generator plant, this paper proposes the ZGT (zonal guarantee technology) to remove the residual heat and contaminant with less energy. CFD software is adopted to do the numerical simulation for the two forms of the new technology. The results show that the novel technology, which can carry out the heat and contaminants simultaneously and effectively in general, may overcome the disadvantage of the ventilation and cooling schemes before. |
doi_str_mv | 10.1109/POWERENG.2009.4915241 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4915241</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4915241</ieee_id><sourcerecordid>4915241</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-a0f241b08a8b09ca930b46a908f845a87804c26ac95e0e1c2d236d74a8f0f8b03</originalsourceid><addsrcrecordid>eNo1kNFKAzEURCNasK39AhHyAW69ySa7iW9Sai0UK1IQfCnp7k27sk1qNhX69wasT8PAnIEZQu4YjBkD_fC2_Ji-T19nYw6gx0IzyQW7ICNdKia4EJxrll-Swb-B4or0OZMyk5IVPTJInNLAGS-vyajrvgAgZ0ppLfrk-9M709LZ0QTjIiJdYbVzvvXbE_WWNq72PlB0P03wbo8uUpt83CE9uhrDNviktG6ww5Zu0WEwMQUObWq7pwcTIp0_0rmLwdfHKjbe3ZCeNW2Ho7MOyep5upq8ZIvlbD55WmSNhpgZsGnlBpRRG9CV0TlsRGE0KKuENKpUICpemEpLBGQVr3le1KUwyoJNSD4kt3-1DSKuD6HZm3Ban9_LfwExcGG1</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Zonal Guarantee Technology of indoor environment for the underground diesel generator plant, part I: Introduction</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Xibin Ma ; Jinsheng Wang ; Baoyi Cheng ; Wenjie Liu ; Guanzhong Peng</creator><creatorcontrib>Xibin Ma ; Jinsheng Wang ; Baoyi Cheng ; Wenjie Liu ; Guanzhong Peng</creatorcontrib><description>It is the premise for the diesel generator set to maintain the proper indoor environment of underground diesel generator plant. Based on the analysis and summarization of the characters of the heat and contaminant distribution in the underground generator plant, this paper proposes the ZGT (zonal guarantee technology) to remove the residual heat and contaminant with less energy. CFD software is adopted to do the numerical simulation for the two forms of the new technology. The results show that the novel technology, which can carry out the heat and contaminants simultaneously and effectively in general, may overcome the disadvantage of the ventilation and cooling schemes before.</description><identifier>ISSN: 2155-5516</identifier><identifier>ISBN: 1424422906</identifier><identifier>ISBN: 9781424446117</identifier><identifier>ISBN: 9781424422906</identifier><identifier>ISBN: 1424446112</identifier><identifier>EISBN: 9781424422913</identifier><identifier>EISBN: 1424422914</identifier><identifier>DOI: 10.1109/POWERENG.2009.4915241</identifier><identifier>LCCN: 2008902127</identifier><language>eng</language><publisher>IEEE</publisher><subject>Character generation ; Cooling ; Diesel engines ; Heat engines ; Indoor environments ; Paper technology ; Pistons ; Power generation ; Programmable logic arrays ; Ventilation</subject><ispartof>2009 International Conference on Power Engineering, Energy and Electrical Drives, 2009, p.217-221</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4915241$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,27904,54898</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4915241$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Xibin Ma</creatorcontrib><creatorcontrib>Jinsheng Wang</creatorcontrib><creatorcontrib>Baoyi Cheng</creatorcontrib><creatorcontrib>Wenjie Liu</creatorcontrib><creatorcontrib>Guanzhong Peng</creatorcontrib><title>Zonal Guarantee Technology of indoor environment for the underground diesel generator plant, part I: Introduction</title><title>2009 International Conference on Power Engineering, Energy and Electrical Drives</title><addtitle>POWERENG</addtitle><description>It is the premise for the diesel generator set to maintain the proper indoor environment of underground diesel generator plant. Based on the analysis and summarization of the characters of the heat and contaminant distribution in the underground generator plant, this paper proposes the ZGT (zonal guarantee technology) to remove the residual heat and contaminant with less energy. CFD software is adopted to do the numerical simulation for the two forms of the new technology. The results show that the novel technology, which can carry out the heat and contaminants simultaneously and effectively in general, may overcome the disadvantage of the ventilation and cooling schemes before.</description><subject>Character generation</subject><subject>Cooling</subject><subject>Diesel engines</subject><subject>Heat engines</subject><subject>Indoor environments</subject><subject>Paper technology</subject><subject>Pistons</subject><subject>Power generation</subject><subject>Programmable logic arrays</subject><subject>Ventilation</subject><issn>2155-5516</issn><isbn>1424422906</isbn><isbn>9781424446117</isbn><isbn>9781424422906</isbn><isbn>1424446112</isbn><isbn>9781424422913</isbn><isbn>1424422914</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2009</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo1kNFKAzEURCNasK39AhHyAW69ySa7iW9Sai0UK1IQfCnp7k27sk1qNhX69wasT8PAnIEZQu4YjBkD_fC2_Ji-T19nYw6gx0IzyQW7ICNdKia4EJxrll-Swb-B4or0OZMyk5IVPTJInNLAGS-vyajrvgAgZ0ppLfrk-9M709LZ0QTjIiJdYbVzvvXbE_WWNq72PlB0P03wbo8uUpt83CE9uhrDNviktG6ww5Zu0WEwMQUObWq7pwcTIp0_0rmLwdfHKjbe3ZCeNW2Ho7MOyep5upq8ZIvlbD55WmSNhpgZsGnlBpRRG9CV0TlsRGE0KKuENKpUICpemEpLBGQVr3le1KUwyoJNSD4kt3-1DSKuD6HZm3Ban9_LfwExcGG1</recordid><startdate>200903</startdate><enddate>200903</enddate><creator>Xibin Ma</creator><creator>Jinsheng Wang</creator><creator>Baoyi Cheng</creator><creator>Wenjie Liu</creator><creator>Guanzhong Peng</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>200903</creationdate><title>Zonal Guarantee Technology of indoor environment for the underground diesel generator plant, part I: Introduction</title><author>Xibin Ma ; Jinsheng Wang ; Baoyi Cheng ; Wenjie Liu ; Guanzhong Peng</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-a0f241b08a8b09ca930b46a908f845a87804c26ac95e0e1c2d236d74a8f0f8b03</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Character generation</topic><topic>Cooling</topic><topic>Diesel engines</topic><topic>Heat engines</topic><topic>Indoor environments</topic><topic>Paper technology</topic><topic>Pistons</topic><topic>Power generation</topic><topic>Programmable logic arrays</topic><topic>Ventilation</topic><toplevel>online_resources</toplevel><creatorcontrib>Xibin Ma</creatorcontrib><creatorcontrib>Jinsheng Wang</creatorcontrib><creatorcontrib>Baoyi Cheng</creatorcontrib><creatorcontrib>Wenjie Liu</creatorcontrib><creatorcontrib>Guanzhong Peng</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Xibin Ma</au><au>Jinsheng Wang</au><au>Baoyi Cheng</au><au>Wenjie Liu</au><au>Guanzhong Peng</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Zonal Guarantee Technology of indoor environment for the underground diesel generator plant, part I: Introduction</atitle><btitle>2009 International Conference on Power Engineering, Energy and Electrical Drives</btitle><stitle>POWERENG</stitle><date>2009-03</date><risdate>2009</risdate><spage>217</spage><epage>221</epage><pages>217-221</pages><issn>2155-5516</issn><isbn>1424422906</isbn><isbn>9781424446117</isbn><isbn>9781424422906</isbn><isbn>1424446112</isbn><eisbn>9781424422913</eisbn><eisbn>1424422914</eisbn><abstract>It is the premise for the diesel generator set to maintain the proper indoor environment of underground diesel generator plant. Based on the analysis and summarization of the characters of the heat and contaminant distribution in the underground generator plant, this paper proposes the ZGT (zonal guarantee technology) to remove the residual heat and contaminant with less energy. CFD software is adopted to do the numerical simulation for the two forms of the new technology. The results show that the novel technology, which can carry out the heat and contaminants simultaneously and effectively in general, may overcome the disadvantage of the ventilation and cooling schemes before.</abstract><pub>IEEE</pub><doi>10.1109/POWERENG.2009.4915241</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 2155-5516 |
ispartof | 2009 International Conference on Power Engineering, Energy and Electrical Drives, 2009, p.217-221 |
issn | 2155-5516 |
language | eng |
recordid | cdi_ieee_primary_4915241 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Character generation Cooling Diesel engines Heat engines Indoor environments Paper technology Pistons Power generation Programmable logic arrays Ventilation |
title | Zonal Guarantee Technology of indoor environment for the underground diesel generator plant, part I: Introduction |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T00%3A30%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Zonal%20Guarantee%20Technology%20of%20indoor%20environment%20for%20the%20underground%20diesel%20generator%20plant,%20part%20I:%20Introduction&rft.btitle=2009%20International%20Conference%20on%20Power%20Engineering,%20Energy%20and%20Electrical%20Drives&rft.au=Xibin%20Ma&rft.date=2009-03&rft.spage=217&rft.epage=221&rft.pages=217-221&rft.issn=2155-5516&rft.isbn=1424422906&rft.isbn_list=9781424446117&rft.isbn_list=9781424422906&rft.isbn_list=1424446112&rft_id=info:doi/10.1109/POWERENG.2009.4915241&rft_dat=%3Cieee_6IE%3E4915241%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781424422913&rft.eisbn_list=1424422914&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4915241&rfr_iscdi=true |