Advancements in Technology and Design of Biomimetic Flow-Sensor Arrays

This paper reports on recent developments to increase the performance of biomimetic flow-sensor arrays by means of several technological advancements in the fabrication procedures and corresponding sensor design optimizations. Advancements include fabrication procedures with higher process latitude...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Bruinink, C.M., Jaganatharaja, R.K., de Boer, M.J., Berenschot, E., Kolster, M.L., Lammerink, T.S.J., Wiegerink, R.J., Krijnen, G.J.M.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 155
container_issue
container_start_page 152
container_title
container_volume
creator Bruinink, C.M.
Jaganatharaja, R.K.
de Boer, M.J.
Berenschot, E.
Kolster, M.L.
Lammerink, T.S.J.
Wiegerink, R.J.
Krijnen, G.J.M.
description This paper reports on recent developments to increase the performance of biomimetic flow-sensor arrays by means of several technological advancements in the fabrication procedures and corresponding sensor design optimizations. Advancements include fabrication procedures with higher process latitude and geometrical modifications of several parts of the flow sensor. The conclusive measurements in this paper support our sensor-model predictions for a 100-fold increase in acoustic sensitivity (down to oscillating flow amplitudes in the order of 1 mmldrs -1 ) translating to substantially higher capacitive outputs in comparison to our first-generation biomimetic flow-sensor arrays.
doi_str_mv 10.1109/MEMSYS.2009.4805341
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4805341</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4805341</ieee_id><sourcerecordid>4805341</sourcerecordid><originalsourceid>FETCH-LOGICAL-i105t-dc2bdf06e520e4f6efba6a0a594ad84c114cf139b3e33ac197151c017ef57cf63</originalsourceid><addsrcrecordid>eNpFkLFOwzAURY0AiVL6BV38AwnvxXYSj6U0gNSKIWVgqhznuRg1DoorUP6-SFTiLkdnOcNlbI6QIoK-36w29XudZgA6lSUoIfGC3aLMpMx0UeLlvxTiik0QSpnkWusbNovxE34nlRAlTFi1aL9NsNRROEbuA9-S_Qj9od-P3ISWP1L0-8B7xx983_mOjt7y6tD_JDWF2A98MQxmjHfs2plDpNmZU_ZWrbbL52T9-vSyXKwTj6COSWuzpnWQk8qApMvJNSY3YJSWpi2lRZTWodCNICGMRV2gQgtYkFOFdbmYsvlf1xPR7mvwnRnG3fkDcQILfk7D</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Advancements in Technology and Design of Biomimetic Flow-Sensor Arrays</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Bruinink, C.M. ; Jaganatharaja, R.K. ; de Boer, M.J. ; Berenschot, E. ; Kolster, M.L. ; Lammerink, T.S.J. ; Wiegerink, R.J. ; Krijnen, G.J.M.</creator><creatorcontrib>Bruinink, C.M. ; Jaganatharaja, R.K. ; de Boer, M.J. ; Berenschot, E. ; Kolster, M.L. ; Lammerink, T.S.J. ; Wiegerink, R.J. ; Krijnen, G.J.M.</creatorcontrib><description>This paper reports on recent developments to increase the performance of biomimetic flow-sensor arrays by means of several technological advancements in the fabrication procedures and corresponding sensor design optimizations. Advancements include fabrication procedures with higher process latitude and geometrical modifications of several parts of the flow sensor. The conclusive measurements in this paper support our sensor-model predictions for a 100-fold increase in acoustic sensitivity (down to oscillating flow amplitudes in the order of 1 mmldrs -1 ) translating to substantially higher capacitive outputs in comparison to our first-generation biomimetic flow-sensor arrays.</description><identifier>ISSN: 1084-6999</identifier><identifier>ISBN: 1424429773</identifier><identifier>ISBN: 9781424429776</identifier><identifier>EISBN: 1424429781</identifier><identifier>EISBN: 9781424429783</identifier><identifier>DOI: 10.1109/MEMSYS.2009.4805341</identifier><language>eng</language><publisher>IEEE</publisher><subject>Acoustic sensors ; Bandwidth ; Biomembranes ; Biomimetics ; Biosensors ; Electrodes ; Fabrication ; Fluid flow measurement ; Hair ; Sensor arrays</subject><ispartof>2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems, 2009, p.152-155</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4805341$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2051,27904,54898</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4805341$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Bruinink, C.M.</creatorcontrib><creatorcontrib>Jaganatharaja, R.K.</creatorcontrib><creatorcontrib>de Boer, M.J.</creatorcontrib><creatorcontrib>Berenschot, E.</creatorcontrib><creatorcontrib>Kolster, M.L.</creatorcontrib><creatorcontrib>Lammerink, T.S.J.</creatorcontrib><creatorcontrib>Wiegerink, R.J.</creatorcontrib><creatorcontrib>Krijnen, G.J.M.</creatorcontrib><title>Advancements in Technology and Design of Biomimetic Flow-Sensor Arrays</title><title>2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems</title><addtitle>MEMSYS</addtitle><description>This paper reports on recent developments to increase the performance of biomimetic flow-sensor arrays by means of several technological advancements in the fabrication procedures and corresponding sensor design optimizations. Advancements include fabrication procedures with higher process latitude and geometrical modifications of several parts of the flow sensor. The conclusive measurements in this paper support our sensor-model predictions for a 100-fold increase in acoustic sensitivity (down to oscillating flow amplitudes in the order of 1 mmldrs -1 ) translating to substantially higher capacitive outputs in comparison to our first-generation biomimetic flow-sensor arrays.</description><subject>Acoustic sensors</subject><subject>Bandwidth</subject><subject>Biomembranes</subject><subject>Biomimetics</subject><subject>Biosensors</subject><subject>Electrodes</subject><subject>Fabrication</subject><subject>Fluid flow measurement</subject><subject>Hair</subject><subject>Sensor arrays</subject><issn>1084-6999</issn><isbn>1424429773</isbn><isbn>9781424429776</isbn><isbn>1424429781</isbn><isbn>9781424429783</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2009</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNpFkLFOwzAURY0AiVL6BV38AwnvxXYSj6U0gNSKIWVgqhznuRg1DoorUP6-SFTiLkdnOcNlbI6QIoK-36w29XudZgA6lSUoIfGC3aLMpMx0UeLlvxTiik0QSpnkWusbNovxE34nlRAlTFi1aL9NsNRROEbuA9-S_Qj9od-P3ISWP1L0-8B7xx983_mOjt7y6tD_JDWF2A98MQxmjHfs2plDpNmZU_ZWrbbL52T9-vSyXKwTj6COSWuzpnWQk8qApMvJNSY3YJSWpi2lRZTWodCNICGMRV2gQgtYkFOFdbmYsvlf1xPR7mvwnRnG3fkDcQILfk7D</recordid><startdate>200901</startdate><enddate>200901</enddate><creator>Bruinink, C.M.</creator><creator>Jaganatharaja, R.K.</creator><creator>de Boer, M.J.</creator><creator>Berenschot, E.</creator><creator>Kolster, M.L.</creator><creator>Lammerink, T.S.J.</creator><creator>Wiegerink, R.J.</creator><creator>Krijnen, G.J.M.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>200901</creationdate><title>Advancements in Technology and Design of Biomimetic Flow-Sensor Arrays</title><author>Bruinink, C.M. ; Jaganatharaja, R.K. ; de Boer, M.J. ; Berenschot, E. ; Kolster, M.L. ; Lammerink, T.S.J. ; Wiegerink, R.J. ; Krijnen, G.J.M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i105t-dc2bdf06e520e4f6efba6a0a594ad84c114cf139b3e33ac197151c017ef57cf63</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Acoustic sensors</topic><topic>Bandwidth</topic><topic>Biomembranes</topic><topic>Biomimetics</topic><topic>Biosensors</topic><topic>Electrodes</topic><topic>Fabrication</topic><topic>Fluid flow measurement</topic><topic>Hair</topic><topic>Sensor arrays</topic><toplevel>online_resources</toplevel><creatorcontrib>Bruinink, C.M.</creatorcontrib><creatorcontrib>Jaganatharaja, R.K.</creatorcontrib><creatorcontrib>de Boer, M.J.</creatorcontrib><creatorcontrib>Berenschot, E.</creatorcontrib><creatorcontrib>Kolster, M.L.</creatorcontrib><creatorcontrib>Lammerink, T.S.J.</creatorcontrib><creatorcontrib>Wiegerink, R.J.</creatorcontrib><creatorcontrib>Krijnen, G.J.M.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Bruinink, C.M.</au><au>Jaganatharaja, R.K.</au><au>de Boer, M.J.</au><au>Berenschot, E.</au><au>Kolster, M.L.</au><au>Lammerink, T.S.J.</au><au>Wiegerink, R.J.</au><au>Krijnen, G.J.M.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Advancements in Technology and Design of Biomimetic Flow-Sensor Arrays</atitle><btitle>2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems</btitle><stitle>MEMSYS</stitle><date>2009-01</date><risdate>2009</risdate><spage>152</spage><epage>155</epage><pages>152-155</pages><issn>1084-6999</issn><isbn>1424429773</isbn><isbn>9781424429776</isbn><eisbn>1424429781</eisbn><eisbn>9781424429783</eisbn><abstract>This paper reports on recent developments to increase the performance of biomimetic flow-sensor arrays by means of several technological advancements in the fabrication procedures and corresponding sensor design optimizations. Advancements include fabrication procedures with higher process latitude and geometrical modifications of several parts of the flow sensor. The conclusive measurements in this paper support our sensor-model predictions for a 100-fold increase in acoustic sensitivity (down to oscillating flow amplitudes in the order of 1 mmldrs -1 ) translating to substantially higher capacitive outputs in comparison to our first-generation biomimetic flow-sensor arrays.</abstract><pub>IEEE</pub><doi>10.1109/MEMSYS.2009.4805341</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1084-6999
ispartof 2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems, 2009, p.152-155
issn 1084-6999
language eng
recordid cdi_ieee_primary_4805341
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Acoustic sensors
Bandwidth
Biomembranes
Biomimetics
Biosensors
Electrodes
Fabrication
Fluid flow measurement
Hair
Sensor arrays
title Advancements in Technology and Design of Biomimetic Flow-Sensor Arrays
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-23T23%3A39%3A54IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Advancements%20in%20Technology%20and%20Design%20of%20Biomimetic%20Flow-Sensor%20Arrays&rft.btitle=2009%20IEEE%2022nd%20International%20Conference%20on%20Micro%20Electro%20Mechanical%20Systems&rft.au=Bruinink,%20C.M.&rft.date=2009-01&rft.spage=152&rft.epage=155&rft.pages=152-155&rft.issn=1084-6999&rft.isbn=1424429773&rft.isbn_list=9781424429776&rft_id=info:doi/10.1109/MEMSYS.2009.4805341&rft_dat=%3Cieee_6IE%3E4805341%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1424429781&rft.eisbn_list=9781424429783&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4805341&rfr_iscdi=true