Calculation of power losses in the damper winding of large hydrogenerators at open-circuit and load conditions

This paper presents an analytical method for the calculation of currents and power losses in the damper winding of large salient-pole synchronous machines at various steady-state operational conditions. The algorithm is based on a damper winding network containing all damper bars of a repetitive sec...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Traxler-Samek, G., Lugand, T., Schwery, A.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper presents an analytical method for the calculation of currents and power losses in the damper winding of large salient-pole synchronous machines at various steady-state operational conditions. The algorithm is based on a damper winding network containing all damper bars of a repetitive section of the machine. The self and mutual inductances as well as the induced voltages are computed taking into account the air-gap permeance function. The presented algorithm is used to compute currents in the damper winding at open-and short-circuit test conditions. The obtained analytical results are compared with the results of transient finite element studies.