Infrared fiber-optic sensor for non-contact temperature measurements
In this study, we have developed a non-contact temperature sensor using a silver halide optical fiber for medical endoscopic usage. We have measured an infrared radiation which is transferred by a silver halide optical fiber from a heat source using a thermal optical power-meter and a thermopile sen...
Gespeichert in:
Hauptverfasser: | , , , , , , , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 503 |
---|---|
container_issue | |
container_start_page | 500 |
container_title | |
container_volume | |
creator | Wook Jae Yoo Dong Hyun Cho Kyoung Won Jang Sang Hun Shin Jeong Ki Seo Soon-Cheol Chung Gye-Rae Tack Bongsoo Lee Byung Gi Park Joo Hyun Moon Sin Kim |
description | In this study, we have developed a non-contact temperature sensor using a silver halide optical fiber for medical endoscopic usage. We have measured an infrared radiation which is transferred by a silver halide optical fiber from a heat source using a thermal optical power-meter and a thermopile sensor. To increase the amount of infrared radiation through the silver halide optical fiber and to the infrared sensors, optical devices such as an infrared collimator and a focusing lens are used. The relationships between the temperatures of a heat source and the measured output signals are determined. The measurable temperature range of a fiber-optic temperature sensor is from 30 to 60degC. It is expected that a non-contact temperature sensor using an infrared optical fiber can be developed for medical and industrial usages based on the results of this study. |
doi_str_mv | 10.1109/ICSENST.2008.4757156 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4757156</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4757156</ieee_id><sourcerecordid>4757156</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-68c69db1af58fd38d9cea12f1971e0ed30c48df21af2d3c1c130e70a213b7b903</originalsourceid><addsrcrecordid>eNo9kMtOwzAURM2jEm3pF8AiP5Byr534sUSlQKUKFi3ryrGvpSCSVLZZ8PcEUViMRpozmsUwdouwRARzt1nt1i-7_ZID6GWlaoW1PGMLozRWvKo4KgXnbMrHuNSgxAWb_QFZXf4DWU_Y7GfDAKKUV2yR0jsAoNRcGD1lD5s-RBvJF6FtKJbDMbeuSNSnIRZhVD_0pRv6bF0uMnVHijZ_Rio6smn0jvqcrtkk2I9Ei5PP2dvjer96LrevT5vV_bZsUdW5lNpJ4xu0odbBC-2NI4s8oFFIQF6Aq7QPfCxwLxw6FEAKLEfRqMaAmLOb392WiA7H2HY2fh1O74hvwKxT0g</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Infrared fiber-optic sensor for non-contact temperature measurements</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Wook Jae Yoo ; Dong Hyun Cho ; Kyoung Won Jang ; Sang Hun Shin ; Jeong Ki Seo ; Soon-Cheol Chung ; Gye-Rae Tack ; Bongsoo Lee ; Byung Gi Park ; Joo Hyun Moon ; Sin Kim</creator><creatorcontrib>Wook Jae Yoo ; Dong Hyun Cho ; Kyoung Won Jang ; Sang Hun Shin ; Jeong Ki Seo ; Soon-Cheol Chung ; Gye-Rae Tack ; Bongsoo Lee ; Byung Gi Park ; Joo Hyun Moon ; Sin Kim</creatorcontrib><description>In this study, we have developed a non-contact temperature sensor using a silver halide optical fiber for medical endoscopic usage. We have measured an infrared radiation which is transferred by a silver halide optical fiber from a heat source using a thermal optical power-meter and a thermopile sensor. To increase the amount of infrared radiation through the silver halide optical fiber and to the infrared sensors, optical devices such as an infrared collimator and a focusing lens are used. The relationships between the temperatures of a heat source and the measured output signals are determined. The measurable temperature range of a fiber-optic temperature sensor is from 30 to 60degC. It is expected that a non-contact temperature sensor using an infrared optical fiber can be developed for medical and industrial usages based on the results of this study.</description><identifier>ISSN: 2156-8065</identifier><identifier>ISBN: 1424421764</identifier><identifier>ISBN: 9781424421763</identifier><identifier>EISSN: 2156-8073</identifier><identifier>EISBN: 9781424421770</identifier><identifier>EISBN: 1424421772</identifier><identifier>DOI: 10.1109/ICSENST.2008.4757156</identifier><identifier>LCCN: 2008901166</identifier><language>eng</language><publisher>IEEE</publisher><subject>Biomedical optical imaging ; fiber-optic sensor ; Heat transfer ; Infrared heating ; Infrared sensors ; non-contact temperature sensor ; Optical fiber sensors ; Optical fibers ; Optical sensors ; Silver ; silver halide optical fiber ; Temperature measurement ; Temperature sensors ; thermal optical power-meter ; thermopile sensor</subject><ispartof>2008 3rd International Conference on Sensing Technology, 2008, p.500-503</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4757156$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4757156$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Wook Jae Yoo</creatorcontrib><creatorcontrib>Dong Hyun Cho</creatorcontrib><creatorcontrib>Kyoung Won Jang</creatorcontrib><creatorcontrib>Sang Hun Shin</creatorcontrib><creatorcontrib>Jeong Ki Seo</creatorcontrib><creatorcontrib>Soon-Cheol Chung</creatorcontrib><creatorcontrib>Gye-Rae Tack</creatorcontrib><creatorcontrib>Bongsoo Lee</creatorcontrib><creatorcontrib>Byung Gi Park</creatorcontrib><creatorcontrib>Joo Hyun Moon</creatorcontrib><creatorcontrib>Sin Kim</creatorcontrib><title>Infrared fiber-optic sensor for non-contact temperature measurements</title><title>2008 3rd International Conference on Sensing Technology</title><addtitle>ICSENST</addtitle><description>In this study, we have developed a non-contact temperature sensor using a silver halide optical fiber for medical endoscopic usage. We have measured an infrared radiation which is transferred by a silver halide optical fiber from a heat source using a thermal optical power-meter and a thermopile sensor. To increase the amount of infrared radiation through the silver halide optical fiber and to the infrared sensors, optical devices such as an infrared collimator and a focusing lens are used. The relationships between the temperatures of a heat source and the measured output signals are determined. The measurable temperature range of a fiber-optic temperature sensor is from 30 to 60degC. It is expected that a non-contact temperature sensor using an infrared optical fiber can be developed for medical and industrial usages based on the results of this study.</description><subject>Biomedical optical imaging</subject><subject>fiber-optic sensor</subject><subject>Heat transfer</subject><subject>Infrared heating</subject><subject>Infrared sensors</subject><subject>non-contact temperature sensor</subject><subject>Optical fiber sensors</subject><subject>Optical fibers</subject><subject>Optical sensors</subject><subject>Silver</subject><subject>silver halide optical fiber</subject><subject>Temperature measurement</subject><subject>Temperature sensors</subject><subject>thermal optical power-meter</subject><subject>thermopile sensor</subject><issn>2156-8065</issn><issn>2156-8073</issn><isbn>1424421764</isbn><isbn>9781424421763</isbn><isbn>9781424421770</isbn><isbn>1424421772</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2008</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo9kMtOwzAURM2jEm3pF8AiP5Byr534sUSlQKUKFi3ryrGvpSCSVLZZ8PcEUViMRpozmsUwdouwRARzt1nt1i-7_ZID6GWlaoW1PGMLozRWvKo4KgXnbMrHuNSgxAWb_QFZXf4DWU_Y7GfDAKKUV2yR0jsAoNRcGD1lD5s-RBvJF6FtKJbDMbeuSNSnIRZhVD_0pRv6bF0uMnVHijZ_Rio6smn0jvqcrtkk2I9Ei5PP2dvjer96LrevT5vV_bZsUdW5lNpJ4xu0odbBC-2NI4s8oFFIQF6Aq7QPfCxwLxw6FEAKLEfRqMaAmLOb392WiA7H2HY2fh1O74hvwKxT0g</recordid><startdate>200811</startdate><enddate>200811</enddate><creator>Wook Jae Yoo</creator><creator>Dong Hyun Cho</creator><creator>Kyoung Won Jang</creator><creator>Sang Hun Shin</creator><creator>Jeong Ki Seo</creator><creator>Soon-Cheol Chung</creator><creator>Gye-Rae Tack</creator><creator>Bongsoo Lee</creator><creator>Byung Gi Park</creator><creator>Joo Hyun Moon</creator><creator>Sin Kim</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>200811</creationdate><title>Infrared fiber-optic sensor for non-contact temperature measurements</title><author>Wook Jae Yoo ; Dong Hyun Cho ; Kyoung Won Jang ; Sang Hun Shin ; Jeong Ki Seo ; Soon-Cheol Chung ; Gye-Rae Tack ; Bongsoo Lee ; Byung Gi Park ; Joo Hyun Moon ; Sin Kim</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-68c69db1af58fd38d9cea12f1971e0ed30c48df21af2d3c1c130e70a213b7b903</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Biomedical optical imaging</topic><topic>fiber-optic sensor</topic><topic>Heat transfer</topic><topic>Infrared heating</topic><topic>Infrared sensors</topic><topic>non-contact temperature sensor</topic><topic>Optical fiber sensors</topic><topic>Optical fibers</topic><topic>Optical sensors</topic><topic>Silver</topic><topic>silver halide optical fiber</topic><topic>Temperature measurement</topic><topic>Temperature sensors</topic><topic>thermal optical power-meter</topic><topic>thermopile sensor</topic><toplevel>online_resources</toplevel><creatorcontrib>Wook Jae Yoo</creatorcontrib><creatorcontrib>Dong Hyun Cho</creatorcontrib><creatorcontrib>Kyoung Won Jang</creatorcontrib><creatorcontrib>Sang Hun Shin</creatorcontrib><creatorcontrib>Jeong Ki Seo</creatorcontrib><creatorcontrib>Soon-Cheol Chung</creatorcontrib><creatorcontrib>Gye-Rae Tack</creatorcontrib><creatorcontrib>Bongsoo Lee</creatorcontrib><creatorcontrib>Byung Gi Park</creatorcontrib><creatorcontrib>Joo Hyun Moon</creatorcontrib><creatorcontrib>Sin Kim</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Wook Jae Yoo</au><au>Dong Hyun Cho</au><au>Kyoung Won Jang</au><au>Sang Hun Shin</au><au>Jeong Ki Seo</au><au>Soon-Cheol Chung</au><au>Gye-Rae Tack</au><au>Bongsoo Lee</au><au>Byung Gi Park</au><au>Joo Hyun Moon</au><au>Sin Kim</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Infrared fiber-optic sensor for non-contact temperature measurements</atitle><btitle>2008 3rd International Conference on Sensing Technology</btitle><stitle>ICSENST</stitle><date>2008-11</date><risdate>2008</risdate><spage>500</spage><epage>503</epage><pages>500-503</pages><issn>2156-8065</issn><eissn>2156-8073</eissn><isbn>1424421764</isbn><isbn>9781424421763</isbn><eisbn>9781424421770</eisbn><eisbn>1424421772</eisbn><abstract>In this study, we have developed a non-contact temperature sensor using a silver halide optical fiber for medical endoscopic usage. We have measured an infrared radiation which is transferred by a silver halide optical fiber from a heat source using a thermal optical power-meter and a thermopile sensor. To increase the amount of infrared radiation through the silver halide optical fiber and to the infrared sensors, optical devices such as an infrared collimator and a focusing lens are used. The relationships between the temperatures of a heat source and the measured output signals are determined. The measurable temperature range of a fiber-optic temperature sensor is from 30 to 60degC. It is expected that a non-contact temperature sensor using an infrared optical fiber can be developed for medical and industrial usages based on the results of this study.</abstract><pub>IEEE</pub><doi>10.1109/ICSENST.2008.4757156</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 2156-8065 |
ispartof | 2008 3rd International Conference on Sensing Technology, 2008, p.500-503 |
issn | 2156-8065 2156-8073 |
language | eng |
recordid | cdi_ieee_primary_4757156 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Biomedical optical imaging fiber-optic sensor Heat transfer Infrared heating Infrared sensors non-contact temperature sensor Optical fiber sensors Optical fibers Optical sensors Silver silver halide optical fiber Temperature measurement Temperature sensors thermal optical power-meter thermopile sensor |
title | Infrared fiber-optic sensor for non-contact temperature measurements |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T09%3A37%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Infrared%20fiber-optic%20sensor%20for%20non-contact%20temperature%20measurements&rft.btitle=2008%203rd%20International%20Conference%20on%20Sensing%20Technology&rft.au=Wook%20Jae%20Yoo&rft.date=2008-11&rft.spage=500&rft.epage=503&rft.pages=500-503&rft.issn=2156-8065&rft.eissn=2156-8073&rft.isbn=1424421764&rft.isbn_list=9781424421763&rft_id=info:doi/10.1109/ICSENST.2008.4757156&rft_dat=%3Cieee_6IE%3E4757156%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781424421770&rft.eisbn_list=1424421772&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4757156&rfr_iscdi=true |