AEP experience with protection of three delta/hex phase angle regulating transformers

American Electric Power installed three 138 kV, 150 MVA delta/hex phase angle regulating (PAR) transformers on the south Texas transmission grid during 2006. These transformers help optimize power flow on the transmission grid until planned 345 kV line construction projects can be completed to impro...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Thompson, M.J., Miller, H., Burger, J.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 105
container_issue
container_start_page 96
container_title
container_volume
creator Thompson, M.J.
Miller, H.
Burger, J.
description American Electric Power installed three 138 kV, 150 MVA delta/hex phase angle regulating (PAR) transformers on the south Texas transmission grid during 2006. These transformers help optimize power flow on the transmission grid until planned 345 kV line construction projects can be completed to improve the strength of the grid in this portion of the power system. The delta/hex PAR transformer is a new single-tank design that promises to be much more economical to build and install than previous designs - improving the economic viability of deployment of these devices on the transmission grid. This paper addresses the challenges of providing fully redundant, sensitive, and secure protection for all types of faults, including turn-to-turn faults in this type of transformer and its surrounding bus work. The protection system includes a mix of conventional protection concepts and a completely new differential protection system that can compensate for the variable phase angle shift introduced by operation of the PAR transformer. The complete protection system was tested using digital model power system transient testing prior to installation in the field.
doi_str_mv 10.1109/PSAMP.2007.4740903
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4740903</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4740903</ieee_id><sourcerecordid>4740903</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-7d0d06fc6e48f733f8559c7128d1cfdc9c526428640ea16032beed97d3543fc43</originalsourceid><addsrcrecordid>eNpVUF9LwzAcjMjAMfsF9CVfoF3-tWkey5g6mFjQPY-Y_NJGurakEee3t-JevHs4Do7jOITuKMkoJWpdv1bPdcYIkZmQgijCr1CiZEkFE4KUea6u_3nBFmg5xwvFSy5vUDJNH2RGzuTMJTpU2xrDeYTgoTeAv3xs8RiGCCb6oceDw7ENANhCF_W6hTMeWz0B1n3TAQ7QfHY6-r7BMeh-ckM4QZhu0cLpboLkoit0eNi-bZ7S_cvjblPtU09lHlNpiSWFMwWI0knO3e9-IykrLTXOGmVyVghWFoKApgXh7B3AKml5Lrgzgq_Q_V-vB4DjGPxJh-_j5Rj-A9EHVTg</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>AEP experience with protection of three delta/hex phase angle regulating transformers</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Thompson, M.J. ; Miller, H. ; Burger, J.</creator><creatorcontrib>Thompson, M.J. ; Miller, H. ; Burger, J.</creatorcontrib><description>American Electric Power installed three 138 kV, 150 MVA delta/hex phase angle regulating (PAR) transformers on the south Texas transmission grid during 2006. These transformers help optimize power flow on the transmission grid until planned 345 kV line construction projects can be completed to improve the strength of the grid in this portion of the power system. The delta/hex PAR transformer is a new single-tank design that promises to be much more economical to build and install than previous designs - improving the economic viability of deployment of these devices on the transmission grid. This paper addresses the challenges of providing fully redundant, sensitive, and secure protection for all types of faults, including turn-to-turn faults in this type of transformer and its surrounding bus work. The protection system includes a mix of conventional protection concepts and a completely new differential protection system that can compensate for the variable phase angle shift introduced by operation of the PAR transformer. The complete protection system was tested using digital model power system transient testing prior to installation in the field.</description><identifier>ISBN: 9781424408542</identifier><identifier>ISBN: 1424408547</identifier><identifier>EISBN: 9781424408559</identifier><identifier>EISBN: 1424408555</identifier><identifier>DOI: 10.1109/PSAMP.2007.4740903</identifier><identifier>LCCN: 200693837</identifier><language>eng</language><publisher>IEEE</publisher><subject>Equations ; Load flow ; Power generation economics ; Power system modeling ; Power system protection ; Power system transients ; Power systems ; Power transmission lines ; System testing ; Transformers</subject><ispartof>2007 Power Systems Conference: Advanced Metering, Protection, Control, Communication, and Distributed Resources, 2007, p.96-105</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4740903$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,27902,54895</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4740903$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Thompson, M.J.</creatorcontrib><creatorcontrib>Miller, H.</creatorcontrib><creatorcontrib>Burger, J.</creatorcontrib><title>AEP experience with protection of three delta/hex phase angle regulating transformers</title><title>2007 Power Systems Conference: Advanced Metering, Protection, Control, Communication, and Distributed Resources</title><addtitle>PSAMP</addtitle><description>American Electric Power installed three 138 kV, 150 MVA delta/hex phase angle regulating (PAR) transformers on the south Texas transmission grid during 2006. These transformers help optimize power flow on the transmission grid until planned 345 kV line construction projects can be completed to improve the strength of the grid in this portion of the power system. The delta/hex PAR transformer is a new single-tank design that promises to be much more economical to build and install than previous designs - improving the economic viability of deployment of these devices on the transmission grid. This paper addresses the challenges of providing fully redundant, sensitive, and secure protection for all types of faults, including turn-to-turn faults in this type of transformer and its surrounding bus work. The protection system includes a mix of conventional protection concepts and a completely new differential protection system that can compensate for the variable phase angle shift introduced by operation of the PAR transformer. The complete protection system was tested using digital model power system transient testing prior to installation in the field.</description><subject>Equations</subject><subject>Load flow</subject><subject>Power generation economics</subject><subject>Power system modeling</subject><subject>Power system protection</subject><subject>Power system transients</subject><subject>Power systems</subject><subject>Power transmission lines</subject><subject>System testing</subject><subject>Transformers</subject><isbn>9781424408542</isbn><isbn>1424408547</isbn><isbn>9781424408559</isbn><isbn>1424408555</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2007</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNpVUF9LwzAcjMjAMfsF9CVfoF3-tWkey5g6mFjQPY-Y_NJGurakEee3t-JevHs4Do7jOITuKMkoJWpdv1bPdcYIkZmQgijCr1CiZEkFE4KUea6u_3nBFmg5xwvFSy5vUDJNH2RGzuTMJTpU2xrDeYTgoTeAv3xs8RiGCCb6oceDw7ENANhCF_W6hTMeWz0B1n3TAQ7QfHY6-r7BMeh-ckM4QZhu0cLpboLkoit0eNi-bZ7S_cvjblPtU09lHlNpiSWFMwWI0knO3e9-IykrLTXOGmVyVghWFoKApgXh7B3AKml5Lrgzgq_Q_V-vB4DjGPxJh-_j5Rj-A9EHVTg</recordid><startdate>200703</startdate><enddate>200703</enddate><creator>Thompson, M.J.</creator><creator>Miller, H.</creator><creator>Burger, J.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>200703</creationdate><title>AEP experience with protection of three delta/hex phase angle regulating transformers</title><author>Thompson, M.J. ; Miller, H. ; Burger, J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-7d0d06fc6e48f733f8559c7128d1cfdc9c526428640ea16032beed97d3543fc43</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Equations</topic><topic>Load flow</topic><topic>Power generation economics</topic><topic>Power system modeling</topic><topic>Power system protection</topic><topic>Power system transients</topic><topic>Power systems</topic><topic>Power transmission lines</topic><topic>System testing</topic><topic>Transformers</topic><toplevel>online_resources</toplevel><creatorcontrib>Thompson, M.J.</creatorcontrib><creatorcontrib>Miller, H.</creatorcontrib><creatorcontrib>Burger, J.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Thompson, M.J.</au><au>Miller, H.</au><au>Burger, J.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>AEP experience with protection of three delta/hex phase angle regulating transformers</atitle><btitle>2007 Power Systems Conference: Advanced Metering, Protection, Control, Communication, and Distributed Resources</btitle><stitle>PSAMP</stitle><date>2007-03</date><risdate>2007</risdate><spage>96</spage><epage>105</epage><pages>96-105</pages><isbn>9781424408542</isbn><isbn>1424408547</isbn><eisbn>9781424408559</eisbn><eisbn>1424408555</eisbn><abstract>American Electric Power installed three 138 kV, 150 MVA delta/hex phase angle regulating (PAR) transformers on the south Texas transmission grid during 2006. These transformers help optimize power flow on the transmission grid until planned 345 kV line construction projects can be completed to improve the strength of the grid in this portion of the power system. The delta/hex PAR transformer is a new single-tank design that promises to be much more economical to build and install than previous designs - improving the economic viability of deployment of these devices on the transmission grid. This paper addresses the challenges of providing fully redundant, sensitive, and secure protection for all types of faults, including turn-to-turn faults in this type of transformer and its surrounding bus work. The protection system includes a mix of conventional protection concepts and a completely new differential protection system that can compensate for the variable phase angle shift introduced by operation of the PAR transformer. The complete protection system was tested using digital model power system transient testing prior to installation in the field.</abstract><pub>IEEE</pub><doi>10.1109/PSAMP.2007.4740903</doi><tpages>10</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 9781424408542
ispartof 2007 Power Systems Conference: Advanced Metering, Protection, Control, Communication, and Distributed Resources, 2007, p.96-105
issn
language eng
recordid cdi_ieee_primary_4740903
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Equations
Load flow
Power generation economics
Power system modeling
Power system protection
Power system transients
Power systems
Power transmission lines
System testing
Transformers
title AEP experience with protection of three delta/hex phase angle regulating transformers
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-08T23%3A49%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=AEP%20experience%20with%20protection%20of%20three%20delta/hex%20phase%20angle%20regulating%20transformers&rft.btitle=2007%20Power%20Systems%20Conference:%20Advanced%20Metering,%20Protection,%20Control,%20Communication,%20and%20Distributed%20Resources&rft.au=Thompson,%20M.J.&rft.date=2007-03&rft.spage=96&rft.epage=105&rft.pages=96-105&rft.isbn=9781424408542&rft.isbn_list=1424408547&rft_id=info:doi/10.1109/PSAMP.2007.4740903&rft_dat=%3Cieee_6IE%3E4740903%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781424408559&rft.eisbn_list=1424408555&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4740903&rfr_iscdi=true