A 2D simple attenuation model for EM waves in human tissues: Comparison with a FDTD 3D simulator for UWB medical radar
This paper describes a simple 2D model for the propagation of electro-magnetic (EM) pulses in human tissues. To assess the reliability of using this model for fast attenuation evaluation of UWB radar pulses in the body, the model is compared with a well known 3D FDTD numeric simulator using a simple...
Gespeichert in:
Hauptverfasser: | , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 4 |
---|---|
container_issue | |
container_start_page | 1 |
container_title | |
container_volume | 3 |
creator | Varotto, G. Staderini, E.M. |
description | This paper describes a simple 2D model for the propagation of electro-magnetic (EM) pulses in human tissues. To assess the reliability of using this model for fast attenuation evaluation of UWB radar pulses in the body, the model is compared with a well known 3D FDTD numeric simulator using a simple multilayer geometry. Results from the 2D model were found in full accordance with the 3D one, allowing making a few considerations over the expected attenuation of UWB return echoes coming from the inner tissue interfaces in a typical medical UWB radar application. |
doi_str_mv | 10.1109/ICUWB.2008.4653401 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4653401</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4653401</ieee_id><sourcerecordid>4653401</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-59872d796ef9e1e70fc0d8276b5ce46938b7b23b2a5ba9ef8808eb60865e86b43</originalsourceid><addsrcrecordid>eNotkM1OwkAUhccoiYC8gG7uCxRnpp0_d1hASTBuIC7JlN6GMf0hnSnEt7ciq5ObnPPlnkPII6NTxqh5XqXbr9cpp1RPEynihLIbMmIJTxKmuRK3ZGKUvtycMynvyLAXHkmh9YCM-pwyVElj7snE-29KKTNSUaOH5DQDPgfvqmOJYEPAurPBNTVUTY4lFE0Liw842xN6cDUcusrWEJz3HfoXSJvqaFvne__ZhQNYWM43c4gvxK60oY__IfrvocLc7W0Jrc1t-0AGhS09Tq46JtvlYpO-R-vPt1U6W0eOKREiYbTiuTISC4MMFS32NO8by0zsMZEm1pnKeJxxKzJrsNCaaswk1VKgllkSj8nTP9ch4u7Yusq2P7vrhvEvZWFgOw</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>A 2D simple attenuation model for EM waves in human tissues: Comparison with a FDTD 3D simulator for UWB medical radar</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Varotto, G. ; Staderini, E.M.</creator><creatorcontrib>Varotto, G. ; Staderini, E.M.</creatorcontrib><description>This paper describes a simple 2D model for the propagation of electro-magnetic (EM) pulses in human tissues. To assess the reliability of using this model for fast attenuation evaluation of UWB radar pulses in the body, the model is compared with a well known 3D FDTD numeric simulator using a simple multilayer geometry. Results from the 2D model were found in full accordance with the 3D one, allowing making a few considerations over the expected attenuation of UWB return echoes coming from the inner tissue interfaces in a typical medical UWB radar application.</description><identifier>ISSN: 2162-6588</identifier><identifier>ISBN: 9781424422166</identifier><identifier>ISBN: 1424422167</identifier><identifier>EISBN: 1424418275</identifier><identifier>EISBN: 9781424418275</identifier><identifier>DOI: 10.1109/ICUWB.2008.4653401</identifier><identifier>LCCN: 2007907699</identifier><language>eng</language><publisher>IEEE</publisher><subject>Atmospheric modeling ; Attenuation ; Attenuation model ; FDTD ; human tissues ; Mathematical model ; medical radar ; Numerical models ; Skin ; Solid modeling ; Ultra wideband radar ; UWB</subject><ispartof>2008 IEEE International Conference on Ultra-Wideband, 2008, Vol.3, p.1-4</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4653401$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,27902,54895</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4653401$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Varotto, G.</creatorcontrib><creatorcontrib>Staderini, E.M.</creatorcontrib><title>A 2D simple attenuation model for EM waves in human tissues: Comparison with a FDTD 3D simulator for UWB medical radar</title><title>2008 IEEE International Conference on Ultra-Wideband</title><addtitle>ICUWB</addtitle><description>This paper describes a simple 2D model for the propagation of electro-magnetic (EM) pulses in human tissues. To assess the reliability of using this model for fast attenuation evaluation of UWB radar pulses in the body, the model is compared with a well known 3D FDTD numeric simulator using a simple multilayer geometry. Results from the 2D model were found in full accordance with the 3D one, allowing making a few considerations over the expected attenuation of UWB return echoes coming from the inner tissue interfaces in a typical medical UWB radar application.</description><subject>Atmospheric modeling</subject><subject>Attenuation</subject><subject>Attenuation model</subject><subject>FDTD</subject><subject>human tissues</subject><subject>Mathematical model</subject><subject>medical radar</subject><subject>Numerical models</subject><subject>Skin</subject><subject>Solid modeling</subject><subject>Ultra wideband radar</subject><subject>UWB</subject><issn>2162-6588</issn><isbn>9781424422166</isbn><isbn>1424422167</isbn><isbn>1424418275</isbn><isbn>9781424418275</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2008</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotkM1OwkAUhccoiYC8gG7uCxRnpp0_d1hASTBuIC7JlN6GMf0hnSnEt7ciq5ObnPPlnkPII6NTxqh5XqXbr9cpp1RPEynihLIbMmIJTxKmuRK3ZGKUvtycMynvyLAXHkmh9YCM-pwyVElj7snE-29KKTNSUaOH5DQDPgfvqmOJYEPAurPBNTVUTY4lFE0Liw842xN6cDUcusrWEJz3HfoXSJvqaFvne__ZhQNYWM43c4gvxK60oY__IfrvocLc7W0Jrc1t-0AGhS09Tq46JtvlYpO-R-vPt1U6W0eOKREiYbTiuTISC4MMFS32NO8by0zsMZEm1pnKeJxxKzJrsNCaaswk1VKgllkSj8nTP9ch4u7Yusq2P7vrhvEvZWFgOw</recordid><startdate>200809</startdate><enddate>200809</enddate><creator>Varotto, G.</creator><creator>Staderini, E.M.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>200809</creationdate><title>A 2D simple attenuation model for EM waves in human tissues: Comparison with a FDTD 3D simulator for UWB medical radar</title><author>Varotto, G. ; Staderini, E.M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-59872d796ef9e1e70fc0d8276b5ce46938b7b23b2a5ba9ef8808eb60865e86b43</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Atmospheric modeling</topic><topic>Attenuation</topic><topic>Attenuation model</topic><topic>FDTD</topic><topic>human tissues</topic><topic>Mathematical model</topic><topic>medical radar</topic><topic>Numerical models</topic><topic>Skin</topic><topic>Solid modeling</topic><topic>Ultra wideband radar</topic><topic>UWB</topic><toplevel>online_resources</toplevel><creatorcontrib>Varotto, G.</creatorcontrib><creatorcontrib>Staderini, E.M.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Varotto, G.</au><au>Staderini, E.M.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>A 2D simple attenuation model for EM waves in human tissues: Comparison with a FDTD 3D simulator for UWB medical radar</atitle><btitle>2008 IEEE International Conference on Ultra-Wideband</btitle><stitle>ICUWB</stitle><date>2008-09</date><risdate>2008</risdate><volume>3</volume><spage>1</spage><epage>4</epage><pages>1-4</pages><issn>2162-6588</issn><isbn>9781424422166</isbn><isbn>1424422167</isbn><eisbn>1424418275</eisbn><eisbn>9781424418275</eisbn><abstract>This paper describes a simple 2D model for the propagation of electro-magnetic (EM) pulses in human tissues. To assess the reliability of using this model for fast attenuation evaluation of UWB radar pulses in the body, the model is compared with a well known 3D FDTD numeric simulator using a simple multilayer geometry. Results from the 2D model were found in full accordance with the 3D one, allowing making a few considerations over the expected attenuation of UWB return echoes coming from the inner tissue interfaces in a typical medical UWB radar application.</abstract><pub>IEEE</pub><doi>10.1109/ICUWB.2008.4653401</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 2162-6588 |
ispartof | 2008 IEEE International Conference on Ultra-Wideband, 2008, Vol.3, p.1-4 |
issn | 2162-6588 |
language | eng |
recordid | cdi_ieee_primary_4653401 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Atmospheric modeling Attenuation Attenuation model FDTD human tissues Mathematical model medical radar Numerical models Skin Solid modeling Ultra wideband radar UWB |
title | A 2D simple attenuation model for EM waves in human tissues: Comparison with a FDTD 3D simulator for UWB medical radar |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T05%3A05%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=A%202D%20simple%20attenuation%20model%20for%20EM%20waves%20in%20human%20tissues:%20Comparison%20with%20a%20FDTD%203D%20simulator%20for%20UWB%20medical%20radar&rft.btitle=2008%20IEEE%20International%20Conference%20on%20Ultra-Wideband&rft.au=Varotto,%20G.&rft.date=2008-09&rft.volume=3&rft.spage=1&rft.epage=4&rft.pages=1-4&rft.issn=2162-6588&rft.isbn=9781424422166&rft.isbn_list=1424422167&rft_id=info:doi/10.1109/ICUWB.2008.4653401&rft_dat=%3Cieee_6IE%3E4653401%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1424418275&rft.eisbn_list=9781424418275&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4653401&rfr_iscdi=true |