Future trends of substation automation system by applying IEC 61850
Substation automation systems (SAS) consist of intelligent electronic devices (IEDs) and the communication networks between them, for implementing control, protection and monitoring tasks in power system. Rectitude of this system depends on integrity and interoperability of its components, especiall...
Gespeichert in:
Hauptverfasser: | , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 4 |
---|---|
container_issue | |
container_start_page | 1 |
container_title | |
container_volume | |
creator | Vadiati, M. Ghorbani, M.A. Ebrahimi, A.R. Arshia, M. |
description | Substation automation systems (SAS) consist of intelligent electronic devices (IEDs) and the communication networks between them, for implementing control, protection and monitoring tasks in power system. Rectitude of this system depends on integrity and interoperability of its components, especially in the case of applying various IEDs from different manufacturer of substation automation system and it is possible by flexible and common protocol in various manufacturers IEDs. For this purpose and in order to interoperability between different manufacturers IEDs, international standard IEC 61850 has been prepared. In this paper the advantages and effects of applying IEC 61850 on SAS performance have been studied and the future modern SAS have been compared to conventional substation automation system. |
doi_str_mv | 10.1109/UPEC.2008.4651480 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4651480</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4651480</ieee_id><sourcerecordid>4651480</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-ff3513258750725176a1922969a3c969b7fa8a0bf06c878e6dc60af0d1c799c13</originalsourceid><addsrcrecordid>eNotj81KxDAURiMiqGMfQNzkBTrem6TJzVJKRwcGdDGuh7RNpDL9oUkXfXuFmc13zurAx9gzwhYR7Ov3V1VuBQBtlS5QEdywRyKyRAqsvmWZNYRKKCWFVfKeZTH-AgBabUDTAyt3S1pmz9PshzbyMfC41DG51I0Dd0sa-4vGNSbf83rlbprOazf88H1Vco1UwBO7C-4cfXblhh131bH8yA-f7_vy7ZB3FlIegixQioJMAUYUaLRDK4TV1snmf2sTHDmoA-iGDHndNhpcgBYbY22DcsNeLtnOe3-a5q5383q63pZ_AmRJ1g</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Future trends of substation automation system by applying IEC 61850</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Vadiati, M. ; Ghorbani, M.A. ; Ebrahimi, A.R. ; Arshia, M.</creator><creatorcontrib>Vadiati, M. ; Ghorbani, M.A. ; Ebrahimi, A.R. ; Arshia, M.</creatorcontrib><description>Substation automation systems (SAS) consist of intelligent electronic devices (IEDs) and the communication networks between them, for implementing control, protection and monitoring tasks in power system. Rectitude of this system depends on integrity and interoperability of its components, especially in the case of applying various IEDs from different manufacturer of substation automation system and it is possible by flexible and common protocol in various manufacturers IEDs. For this purpose and in order to interoperability between different manufacturers IEDs, international standard IEC 61850 has been prepared. In this paper the advantages and effects of applying IEC 61850 on SAS performance have been studied and the future modern SAS have been compared to conventional substation automation system.</description><identifier>ISBN: 9781424432943</identifier><identifier>ISBN: 1424432944</identifier><identifier>EISBN: 8889884096</identifier><identifier>EISBN: 9788889884096</identifier><identifier>DOI: 10.1109/UPEC.2008.4651480</identifier><language>eng</language><publisher>IEEE</publisher><subject>Control and Protection ; IEC ; IEC 61850 ; Intelligent Electronic Device(IED) ; Monitoring ; Object oriented modeling ; Protocols ; Substation automation ; Substation automation system (SAS) ; Substations ; Synthetic aperture sonar</subject><ispartof>2008 43rd International Universities Power Engineering Conference, 2008, p.1-4</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4651480$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4651480$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Vadiati, M.</creatorcontrib><creatorcontrib>Ghorbani, M.A.</creatorcontrib><creatorcontrib>Ebrahimi, A.R.</creatorcontrib><creatorcontrib>Arshia, M.</creatorcontrib><title>Future trends of substation automation system by applying IEC 61850</title><title>2008 43rd International Universities Power Engineering Conference</title><addtitle>UPEC</addtitle><description>Substation automation systems (SAS) consist of intelligent electronic devices (IEDs) and the communication networks between them, for implementing control, protection and monitoring tasks in power system. Rectitude of this system depends on integrity and interoperability of its components, especially in the case of applying various IEDs from different manufacturer of substation automation system and it is possible by flexible and common protocol in various manufacturers IEDs. For this purpose and in order to interoperability between different manufacturers IEDs, international standard IEC 61850 has been prepared. In this paper the advantages and effects of applying IEC 61850 on SAS performance have been studied and the future modern SAS have been compared to conventional substation automation system.</description><subject>Control and Protection</subject><subject>IEC</subject><subject>IEC 61850</subject><subject>Intelligent Electronic Device(IED)</subject><subject>Monitoring</subject><subject>Object oriented modeling</subject><subject>Protocols</subject><subject>Substation automation</subject><subject>Substation automation system (SAS)</subject><subject>Substations</subject><subject>Synthetic aperture sonar</subject><isbn>9781424432943</isbn><isbn>1424432944</isbn><isbn>8889884096</isbn><isbn>9788889884096</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2008</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotj81KxDAURiMiqGMfQNzkBTrem6TJzVJKRwcGdDGuh7RNpDL9oUkXfXuFmc13zurAx9gzwhYR7Ov3V1VuBQBtlS5QEdywRyKyRAqsvmWZNYRKKCWFVfKeZTH-AgBabUDTAyt3S1pmz9PshzbyMfC41DG51I0Dd0sa-4vGNSbf83rlbprOazf88H1Vco1UwBO7C-4cfXblhh131bH8yA-f7_vy7ZB3FlIegixQioJMAUYUaLRDK4TV1snmf2sTHDmoA-iGDHndNhpcgBYbY22DcsNeLtnOe3-a5q5383q63pZ_AmRJ1g</recordid><startdate>200809</startdate><enddate>200809</enddate><creator>Vadiati, M.</creator><creator>Ghorbani, M.A.</creator><creator>Ebrahimi, A.R.</creator><creator>Arshia, M.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>200809</creationdate><title>Future trends of substation automation system by applying IEC 61850</title><author>Vadiati, M. ; Ghorbani, M.A. ; Ebrahimi, A.R. ; Arshia, M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-ff3513258750725176a1922969a3c969b7fa8a0bf06c878e6dc60af0d1c799c13</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Control and Protection</topic><topic>IEC</topic><topic>IEC 61850</topic><topic>Intelligent Electronic Device(IED)</topic><topic>Monitoring</topic><topic>Object oriented modeling</topic><topic>Protocols</topic><topic>Substation automation</topic><topic>Substation automation system (SAS)</topic><topic>Substations</topic><topic>Synthetic aperture sonar</topic><toplevel>online_resources</toplevel><creatorcontrib>Vadiati, M.</creatorcontrib><creatorcontrib>Ghorbani, M.A.</creatorcontrib><creatorcontrib>Ebrahimi, A.R.</creatorcontrib><creatorcontrib>Arshia, M.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Vadiati, M.</au><au>Ghorbani, M.A.</au><au>Ebrahimi, A.R.</au><au>Arshia, M.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Future trends of substation automation system by applying IEC 61850</atitle><btitle>2008 43rd International Universities Power Engineering Conference</btitle><stitle>UPEC</stitle><date>2008-09</date><risdate>2008</risdate><spage>1</spage><epage>4</epage><pages>1-4</pages><isbn>9781424432943</isbn><isbn>1424432944</isbn><eisbn>8889884096</eisbn><eisbn>9788889884096</eisbn><abstract>Substation automation systems (SAS) consist of intelligent electronic devices (IEDs) and the communication networks between them, for implementing control, protection and monitoring tasks in power system. Rectitude of this system depends on integrity and interoperability of its components, especially in the case of applying various IEDs from different manufacturer of substation automation system and it is possible by flexible and common protocol in various manufacturers IEDs. For this purpose and in order to interoperability between different manufacturers IEDs, international standard IEC 61850 has been prepared. In this paper the advantages and effects of applying IEC 61850 on SAS performance have been studied and the future modern SAS have been compared to conventional substation automation system.</abstract><pub>IEEE</pub><doi>10.1109/UPEC.2008.4651480</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISBN: 9781424432943 |
ispartof | 2008 43rd International Universities Power Engineering Conference, 2008, p.1-4 |
issn | |
language | eng |
recordid | cdi_ieee_primary_4651480 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Control and Protection IEC IEC 61850 Intelligent Electronic Device(IED) Monitoring Object oriented modeling Protocols Substation automation Substation automation system (SAS) Substations Synthetic aperture sonar |
title | Future trends of substation automation system by applying IEC 61850 |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T03%3A57%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Future%20trends%20of%20substation%20automation%20system%20by%20applying%20IEC%2061850&rft.btitle=2008%2043rd%20International%20Universities%20Power%20Engineering%20Conference&rft.au=Vadiati,%20M.&rft.date=2008-09&rft.spage=1&rft.epage=4&rft.pages=1-4&rft.isbn=9781424432943&rft.isbn_list=1424432944&rft_id=info:doi/10.1109/UPEC.2008.4651480&rft_dat=%3Cieee_6IE%3E4651480%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=8889884096&rft.eisbn_list=9788889884096&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4651480&rfr_iscdi=true |