Assessment of power swing blocking functions of line protective relays for a near scenario of the Uruguayan system

During normal operation of an electrical power system, there will be some conditions like faults or other disturbances which may cause loss of synchronism between areas. When loss of synchronism takes place, asynchronous areas should be separated to avoid equipment damaged or extensive outages. This...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Sena, C., Franco, R., Giusto, A.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 7
container_issue
container_start_page 1
container_title
container_volume
creator Sena, C.
Franco, R.
Giusto, A.
description During normal operation of an electrical power system, there will be some conditions like faults or other disturbances which may cause loss of synchronism between areas. When loss of synchronism takes place, asynchronous areas should be separated to avoid equipment damaged or extensive outages. This paper describes the assessment of the protection system of a part of the Uruguayan power system. The focus is on the incorporation of a big consumer with generation capacity. The involved added apparent power generation is about 10% of the maximum historical Uruguayan load. The article describes a set of studies on the protective system associated to transmission lines feeding the new consumer. Particular attention is paid to blocking power swing functions of the involved relays. Power system simulations and relay tests have been performed, to evaluate the performance of the relays under power swing conditions. The foreknowledge makes possible to avoid undesired operation.
doi_str_mv 10.1109/TDC-LA.2008.4641714
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4641714</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4641714</ieee_id><sourcerecordid>4641714</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-eecf083aca030cbd61b204d484c109d41cb4f5e2c62b6dbc22d2cec83b959a2a3</originalsourceid><addsrcrecordid>eNpFkM1OwzAQhI1QJWjpE_TiF0jwX9L4WIWfIkXiEs6V7WyKIbUjO6XK25OISsxlZ1bf7mEQ2lCSUkrkY_1UJtUuZYQUqcgF3VJxg5ZUMCEYowW__Q_bbIGWMygJzXJ5h9YxfpFJXOZbQu9R2MUIMZ7ADdi3uPcXCDherDti3XnzPZv27MxgvYsz0VkHuA9-gGn3AzhAp8aIWx-wwg7UdG3AqWD9TA-fgD_C-XhWo3I4jnGA0wNatKqLsL7OFapfnutyn1Tvr2_lrkqsJEMCYFpScGUU4cToJqeaEdGIQpipg0ZQo0WbATM503mjDWMNM2AKrmUmFVN8hTZ_by0AHPpgTyqMh2tf_Bd7fGAD</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Assessment of power swing blocking functions of line protective relays for a near scenario of the Uruguayan system</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Sena, C. ; Franco, R. ; Giusto, A.</creator><creatorcontrib>Sena, C. ; Franco, R. ; Giusto, A.</creatorcontrib><description>During normal operation of an electrical power system, there will be some conditions like faults or other disturbances which may cause loss of synchronism between areas. When loss of synchronism takes place, asynchronous areas should be separated to avoid equipment damaged or extensive outages. This paper describes the assessment of the protection system of a part of the Uruguayan power system. The focus is on the incorporation of a big consumer with generation capacity. The involved added apparent power generation is about 10% of the maximum historical Uruguayan load. The article describes a set of studies on the protective system associated to transmission lines feeding the new consumer. Particular attention is paid to blocking power swing functions of the involved relays. Power system simulations and relay tests have been performed, to evaluate the performance of the relays under power swing conditions. The foreknowledge makes possible to avoid undesired operation.</description><identifier>ISBN: 1424422175</identifier><identifier>ISBN: 9781424422173</identifier><identifier>EISBN: 1424422183</identifier><identifier>EISBN: 9781424422180</identifier><identifier>DOI: 10.1109/TDC-LA.2008.4641714</identifier><identifier>LCCN: 2008901569</identifier><language>eng</language><publisher>IEEE</publisher><subject>Distance measurement ; Impedance ; Load modeling ; Out-of-step ; Power swing ; Power swing blocking ; Power system stability ; Power system transient stability ; Power systems ; Relays ; Trajectory</subject><ispartof>2008 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America, 2008, p.1-7</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4641714$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,27902,54895</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4641714$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Sena, C.</creatorcontrib><creatorcontrib>Franco, R.</creatorcontrib><creatorcontrib>Giusto, A.</creatorcontrib><title>Assessment of power swing blocking functions of line protective relays for a near scenario of the Uruguayan system</title><title>2008 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America</title><addtitle>TDC-LA</addtitle><description>During normal operation of an electrical power system, there will be some conditions like faults or other disturbances which may cause loss of synchronism between areas. When loss of synchronism takes place, asynchronous areas should be separated to avoid equipment damaged or extensive outages. This paper describes the assessment of the protection system of a part of the Uruguayan power system. The focus is on the incorporation of a big consumer with generation capacity. The involved added apparent power generation is about 10% of the maximum historical Uruguayan load. The article describes a set of studies on the protective system associated to transmission lines feeding the new consumer. Particular attention is paid to blocking power swing functions of the involved relays. Power system simulations and relay tests have been performed, to evaluate the performance of the relays under power swing conditions. The foreknowledge makes possible to avoid undesired operation.</description><subject>Distance measurement</subject><subject>Impedance</subject><subject>Load modeling</subject><subject>Out-of-step</subject><subject>Power swing</subject><subject>Power swing blocking</subject><subject>Power system stability</subject><subject>Power system transient stability</subject><subject>Power systems</subject><subject>Relays</subject><subject>Trajectory</subject><isbn>1424422175</isbn><isbn>9781424422173</isbn><isbn>1424422183</isbn><isbn>9781424422180</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2008</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNpFkM1OwzAQhI1QJWjpE_TiF0jwX9L4WIWfIkXiEs6V7WyKIbUjO6XK25OISsxlZ1bf7mEQ2lCSUkrkY_1UJtUuZYQUqcgF3VJxg5ZUMCEYowW__Q_bbIGWMygJzXJ5h9YxfpFJXOZbQu9R2MUIMZ7ADdi3uPcXCDherDti3XnzPZv27MxgvYsz0VkHuA9-gGn3AzhAp8aIWx-wwg7UdG3AqWD9TA-fgD_C-XhWo3I4jnGA0wNatKqLsL7OFapfnutyn1Tvr2_lrkqsJEMCYFpScGUU4cToJqeaEdGIQpipg0ZQo0WbATM503mjDWMNM2AKrmUmFVN8hTZ_by0AHPpgTyqMh2tf_Bd7fGAD</recordid><startdate>200808</startdate><enddate>200808</enddate><creator>Sena, C.</creator><creator>Franco, R.</creator><creator>Giusto, A.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>200808</creationdate><title>Assessment of power swing blocking functions of line protective relays for a near scenario of the Uruguayan system</title><author>Sena, C. ; Franco, R. ; Giusto, A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-eecf083aca030cbd61b204d484c109d41cb4f5e2c62b6dbc22d2cec83b959a2a3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Distance measurement</topic><topic>Impedance</topic><topic>Load modeling</topic><topic>Out-of-step</topic><topic>Power swing</topic><topic>Power swing blocking</topic><topic>Power system stability</topic><topic>Power system transient stability</topic><topic>Power systems</topic><topic>Relays</topic><topic>Trajectory</topic><toplevel>online_resources</toplevel><creatorcontrib>Sena, C.</creatorcontrib><creatorcontrib>Franco, R.</creatorcontrib><creatorcontrib>Giusto, A.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Sena, C.</au><au>Franco, R.</au><au>Giusto, A.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Assessment of power swing blocking functions of line protective relays for a near scenario of the Uruguayan system</atitle><btitle>2008 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America</btitle><stitle>TDC-LA</stitle><date>2008-08</date><risdate>2008</risdate><spage>1</spage><epage>7</epage><pages>1-7</pages><isbn>1424422175</isbn><isbn>9781424422173</isbn><eisbn>1424422183</eisbn><eisbn>9781424422180</eisbn><abstract>During normal operation of an electrical power system, there will be some conditions like faults or other disturbances which may cause loss of synchronism between areas. When loss of synchronism takes place, asynchronous areas should be separated to avoid equipment damaged or extensive outages. This paper describes the assessment of the protection system of a part of the Uruguayan power system. The focus is on the incorporation of a big consumer with generation capacity. The involved added apparent power generation is about 10% of the maximum historical Uruguayan load. The article describes a set of studies on the protective system associated to transmission lines feeding the new consumer. Particular attention is paid to blocking power swing functions of the involved relays. Power system simulations and relay tests have been performed, to evaluate the performance of the relays under power swing conditions. The foreknowledge makes possible to avoid undesired operation.</abstract><pub>IEEE</pub><doi>10.1109/TDC-LA.2008.4641714</doi><tpages>7</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 1424422175
ispartof 2008 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America, 2008, p.1-7
issn
language eng
recordid cdi_ieee_primary_4641714
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Distance measurement
Impedance
Load modeling
Out-of-step
Power swing
Power swing blocking
Power system stability
Power system transient stability
Power systems
Relays
Trajectory
title Assessment of power swing blocking functions of line protective relays for a near scenario of the Uruguayan system
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T12%3A17%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Assessment%20of%20power%20swing%20blocking%20functions%20of%20line%20protective%20relays%20for%20a%20near%20scenario%20of%20the%20Uruguayan%20system&rft.btitle=2008%20IEEE/PES%20Transmission%20and%20Distribution%20Conference%20and%20Exposition:%20Latin%20America&rft.au=Sena,%20C.&rft.date=2008-08&rft.spage=1&rft.epage=7&rft.pages=1-7&rft.isbn=1424422175&rft.isbn_list=9781424422173&rft_id=info:doi/10.1109/TDC-LA.2008.4641714&rft_dat=%3Cieee_6IE%3E4641714%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1424422183&rft.eisbn_list=9781424422180&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4641714&rfr_iscdi=true