Measuring no - load and load noise of power transformers using the sound pressure and sound intensity methods - Part - II: Indoors measurements

As mentioned earlier, this paper presents results of a comprehensive study conducted to identify magnitudes of contributors to the inherent difference between sound pressure and sound intensity measurements of transformer noise. From this study, appropriate conditions for accurate indoors measuremen...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Girgis, R.S., Garner, K., Bernesjo, M., Anger, J., Chu, D.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 8
container_issue
container_start_page 1
container_title
container_volume
creator Girgis, R.S.
Garner, K.
Bernesjo, M.
Anger, J.
Chu, D.
description As mentioned earlier, this paper presents results of a comprehensive study conducted to identify magnitudes of contributors to the inherent difference between sound pressure and sound intensity measurements of transformer noise. From this study, appropriate conditions for accurate indoors measurement of transformer noise, when using the sound intensity method, have been derived. Also, magnitudes of the inherent inaccuracies in the measurements using the sound pressure method have been determined. Finally, modifications to the existing IEC and IEEE Industry Standards of measuring transformer noise are proposed. Part - I of the paper presented results of the outdoors measurements while this Part - II presents results of the indoors measurements made of no-load and load noise of 48 power transformers of 12 - 336 MVA power ratings, using both the sound pressure and sound intensity methods.
doi_str_mv 10.1109/PES.2008.4596784
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4596784</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4596784</ieee_id><sourcerecordid>4596784</sourcerecordid><originalsourceid>FETCH-ieee_primary_45967843</originalsourceid><addsrcrecordid>eNp9j89OwzAMxoMAiQG9I3HxC7QkbbI2XNEQPSBNgvsUqS4LWpIqToX2FLwyYRtXfPn8R7_PNmN3gldCcP2wXr1VNeddJZVetp08Y9dC1lIKzZf6nBW67f5qxS_YQuimLpUS7RUriD55DqmaWnQL9v2KhuZo_Qf4ACXsghnA-OGY-GAJIYwwhS-MkKLxNIboMBLM9AulLQKFOQNTRMpOeKCPLesTerJpDw7TNgyUF6xNTFn6_hF6P4SQndzhBHToE92yy9HsCIuT3rD759X700tpEXEzRetM3G9Ofzf_T38Ac25ZyA</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Measuring no - load and load noise of power transformers using the sound pressure and sound intensity methods - Part - II: Indoors measurements</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Girgis, R.S. ; Garner, K. ; Bernesjo, M. ; Anger, J. ; Chu, D.</creator><creatorcontrib>Girgis, R.S. ; Garner, K. ; Bernesjo, M. ; Anger, J. ; Chu, D.</creatorcontrib><description>As mentioned earlier, this paper presents results of a comprehensive study conducted to identify magnitudes of contributors to the inherent difference between sound pressure and sound intensity measurements of transformer noise. From this study, appropriate conditions for accurate indoors measurement of transformer noise, when using the sound intensity method, have been derived. Also, magnitudes of the inherent inaccuracies in the measurements using the sound pressure method have been determined. Finally, modifications to the existing IEC and IEEE Industry Standards of measuring transformer noise are proposed. Part - I of the paper presented results of the outdoors measurements while this Part - II presents results of the indoors measurements made of no-load and load noise of 48 power transformers of 12 - 336 MVA power ratings, using both the sound pressure and sound intensity methods.</description><identifier>ISSN: 1932-5517</identifier><identifier>ISBN: 9781424419050</identifier><identifier>ISBN: 1424419050</identifier><identifier>EISBN: 1424419069</identifier><identifier>EISBN: 9781424419067</identifier><identifier>DOI: 10.1109/PES.2008.4596784</identifier><language>eng</language><publisher>IEEE</publisher><subject>Frequency measurement ; Noise ; Noise measurement ; Power measurement ; Power transformers ; Pressure measurement ; Sound Intensity ; Sound Power ; Sound Power Measurement ; Transformer cores ; Transformer Noise</subject><ispartof>2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century, 2008, p.1-8</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4596784$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4596784$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Girgis, R.S.</creatorcontrib><creatorcontrib>Garner, K.</creatorcontrib><creatorcontrib>Bernesjo, M.</creatorcontrib><creatorcontrib>Anger, J.</creatorcontrib><creatorcontrib>Chu, D.</creatorcontrib><title>Measuring no - load and load noise of power transformers using the sound pressure and sound intensity methods - Part - II: Indoors measurements</title><title>2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century</title><addtitle>PES</addtitle><description>As mentioned earlier, this paper presents results of a comprehensive study conducted to identify magnitudes of contributors to the inherent difference between sound pressure and sound intensity measurements of transformer noise. From this study, appropriate conditions for accurate indoors measurement of transformer noise, when using the sound intensity method, have been derived. Also, magnitudes of the inherent inaccuracies in the measurements using the sound pressure method have been determined. Finally, modifications to the existing IEC and IEEE Industry Standards of measuring transformer noise are proposed. Part - I of the paper presented results of the outdoors measurements while this Part - II presents results of the indoors measurements made of no-load and load noise of 48 power transformers of 12 - 336 MVA power ratings, using both the sound pressure and sound intensity methods.</description><subject>Frequency measurement</subject><subject>Noise</subject><subject>Noise measurement</subject><subject>Power measurement</subject><subject>Power transformers</subject><subject>Pressure measurement</subject><subject>Sound Intensity</subject><subject>Sound Power</subject><subject>Sound Power Measurement</subject><subject>Transformer cores</subject><subject>Transformer Noise</subject><issn>1932-5517</issn><isbn>9781424419050</isbn><isbn>1424419050</isbn><isbn>1424419069</isbn><isbn>9781424419067</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2008</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNp9j89OwzAMxoMAiQG9I3HxC7QkbbI2XNEQPSBNgvsUqS4LWpIqToX2FLwyYRtXfPn8R7_PNmN3gldCcP2wXr1VNeddJZVetp08Y9dC1lIKzZf6nBW67f5qxS_YQuimLpUS7RUriD55DqmaWnQL9v2KhuZo_Qf4ACXsghnA-OGY-GAJIYwwhS-MkKLxNIboMBLM9AulLQKFOQNTRMpOeKCPLesTerJpDw7TNgyUF6xNTFn6_hF6P4SQndzhBHToE92yy9HsCIuT3rD759X700tpEXEzRetM3G9Ofzf_T38Ac25ZyA</recordid><startdate>200807</startdate><enddate>200807</enddate><creator>Girgis, R.S.</creator><creator>Garner, K.</creator><creator>Bernesjo, M.</creator><creator>Anger, J.</creator><creator>Chu, D.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>200807</creationdate><title>Measuring no - load and load noise of power transformers using the sound pressure and sound intensity methods - Part - II: Indoors measurements</title><author>Girgis, R.S. ; Garner, K. ; Bernesjo, M. ; Anger, J. ; Chu, D.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-ieee_primary_45967843</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Frequency measurement</topic><topic>Noise</topic><topic>Noise measurement</topic><topic>Power measurement</topic><topic>Power transformers</topic><topic>Pressure measurement</topic><topic>Sound Intensity</topic><topic>Sound Power</topic><topic>Sound Power Measurement</topic><topic>Transformer cores</topic><topic>Transformer Noise</topic><toplevel>online_resources</toplevel><creatorcontrib>Girgis, R.S.</creatorcontrib><creatorcontrib>Garner, K.</creatorcontrib><creatorcontrib>Bernesjo, M.</creatorcontrib><creatorcontrib>Anger, J.</creatorcontrib><creatorcontrib>Chu, D.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Girgis, R.S.</au><au>Garner, K.</au><au>Bernesjo, M.</au><au>Anger, J.</au><au>Chu, D.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Measuring no - load and load noise of power transformers using the sound pressure and sound intensity methods - Part - II: Indoors measurements</atitle><btitle>2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century</btitle><stitle>PES</stitle><date>2008-07</date><risdate>2008</risdate><spage>1</spage><epage>8</epage><pages>1-8</pages><issn>1932-5517</issn><isbn>9781424419050</isbn><isbn>1424419050</isbn><eisbn>1424419069</eisbn><eisbn>9781424419067</eisbn><abstract>As mentioned earlier, this paper presents results of a comprehensive study conducted to identify magnitudes of contributors to the inherent difference between sound pressure and sound intensity measurements of transformer noise. From this study, appropriate conditions for accurate indoors measurement of transformer noise, when using the sound intensity method, have been derived. Also, magnitudes of the inherent inaccuracies in the measurements using the sound pressure method have been determined. Finally, modifications to the existing IEC and IEEE Industry Standards of measuring transformer noise are proposed. Part - I of the paper presented results of the outdoors measurements while this Part - II presents results of the indoors measurements made of no-load and load noise of 48 power transformers of 12 - 336 MVA power ratings, using both the sound pressure and sound intensity methods.</abstract><pub>IEEE</pub><doi>10.1109/PES.2008.4596784</doi></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1932-5517
ispartof 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century, 2008, p.1-8
issn 1932-5517
language eng
recordid cdi_ieee_primary_4596784
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Frequency measurement
Noise
Noise measurement
Power measurement
Power transformers
Pressure measurement
Sound Intensity
Sound Power
Sound Power Measurement
Transformer cores
Transformer Noise
title Measuring no - load and load noise of power transformers using the sound pressure and sound intensity methods - Part - II: Indoors measurements
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T18%3A39%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Measuring%20no%20-%20load%20and%20load%20noise%20of%20power%20transformers%20using%20the%20sound%20pressure%20and%20sound%20intensity%20methods%20-%20Part%20-%20II:%20Indoors%20measurements&rft.btitle=2008%20IEEE%20Power%20and%20Energy%20Society%20General%20Meeting%20-%20Conversion%20and%20Delivery%20of%20Electrical%20Energy%20in%20the%2021st%20Century&rft.au=Girgis,%20R.S.&rft.date=2008-07&rft.spage=1&rft.epage=8&rft.pages=1-8&rft.issn=1932-5517&rft.isbn=9781424419050&rft.isbn_list=1424419050&rft_id=info:doi/10.1109/PES.2008.4596784&rft_dat=%3Cieee_6IE%3E4596784%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1424419069&rft.eisbn_list=9781424419067&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4596784&rfr_iscdi=true