Ultra-high frequency spectral characteristics of partial discharge in insulation oil

We have designed and manufactured four types of typical defects found in power transformers to simulate partial discharge (PD) in oil insulated power transformers. Stable PD signals were generated by applying AC voltages on to the PD cells. We measured spectral response of PD signals from these defe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Sun-geun Goo, Hyeongjun Ju, Kijun Park, Kiseon Han, Jinyul Yoon
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 67
container_issue
container_start_page 64
container_title
container_volume
creator Sun-geun Goo
Hyeongjun Ju
Kijun Park
Kiseon Han
Jinyul Yoon
description We have designed and manufactured four types of typical defects found in power transformers to simulate partial discharge (PD) in oil insulated power transformers. Stable PD signals were generated by applying AC voltages on to the PD cells. We measured spectral response of PD signals from these defects using our Ultra-high frequency (UHF) PD measuring system and apparent discharge using IEC60270 PD detector simultaneously. Partial discharges from the defects in oil generated well detectable UHF signal up to about 2 GHz. UHF PD patterns were recorded and analyzed for each defect types. The phase resolved partial discharge (PRPD) patterns of defect obtained from UHF range were different from each other. The patterns of UHF PD signals were also different from those obtained from that of conventional method. Type of defect could be identified by obtaining PRPD patterns.
doi_str_mv 10.1109/CMD.2008.4580231
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4580231</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4580231</ieee_id><sourcerecordid>4580231</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-3a4145bcef921e7772ec99a7593eb007563abf0a775ee7f340aca59e3f0e32453</originalsourceid><addsrcrecordid>eNpVUEtLAzEQjkhBrb0LXvIHtua52TnKqlWoeKnnMhsn3cja1mR76L83Yi8OA8P3YPhmGLuRYi6lgLv29WGuhGjmxjZCaXnGZuAaaZQxslaqPv-HJUzYVbE7EBakvWCznD9FKWO1BnvJVu_DmLDq46bnIdH3gbb-yPOefKEH7ntM6EdKMY_RZ74LfI9pjEX6iPlX3RCP29L5MOAYd1u-i8M1mwQcMs1Oc8pWT4-r9rlavi1e2vtlFUGMlUYjje08BVCSnHOKPAA6C5q6EtnWGrsg0DlL5II2Aj1aIB0EaVUOmLLbv7WRiNb7FL8wHdenv-gf9GRUqw</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Ultra-high frequency spectral characteristics of partial discharge in insulation oil</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Sun-geun Goo ; Hyeongjun Ju ; Kijun Park ; Kiseon Han ; Jinyul Yoon</creator><creatorcontrib>Sun-geun Goo ; Hyeongjun Ju ; Kijun Park ; Kiseon Han ; Jinyul Yoon</creatorcontrib><description>We have designed and manufactured four types of typical defects found in power transformers to simulate partial discharge (PD) in oil insulated power transformers. Stable PD signals were generated by applying AC voltages on to the PD cells. We measured spectral response of PD signals from these defects using our Ultra-high frequency (UHF) PD measuring system and apparent discharge using IEC60270 PD detector simultaneously. Partial discharges from the defects in oil generated well detectable UHF signal up to about 2 GHz. UHF PD patterns were recorded and analyzed for each defect types. The phase resolved partial discharge (PRPD) patterns of defect obtained from UHF range were different from each other. The patterns of UHF PD signals were also different from those obtained from that of conventional method. Type of defect could be identified by obtaining PRPD patterns.</description><identifier>ISBN: 9781424416219</identifier><identifier>ISBN: 1424416213</identifier><identifier>EISBN: 9781424416226</identifier><identifier>EISBN: 1424416221</identifier><identifier>DOI: 10.1109/CMD.2008.4580231</identifier><identifier>LCCN: 2007905915</identifier><language>eng</language><publisher>IEEE</publisher><subject>Frequency measurement ; Oil ; Oil insulation ; Partial Discharge ; Partial discharge measurement ; Partial discharges ; Petroleum ; Power transformer insulation ; Power transformers ; PRPD ; Signal generators ; UHF ; UHF measurements ; Virtual manufacturing</subject><ispartof>2008 International Conference on Condition Monitoring and Diagnosis, 2008, p.64-67</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4580231$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,27902,54895</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4580231$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Sun-geun Goo</creatorcontrib><creatorcontrib>Hyeongjun Ju</creatorcontrib><creatorcontrib>Kijun Park</creatorcontrib><creatorcontrib>Kiseon Han</creatorcontrib><creatorcontrib>Jinyul Yoon</creatorcontrib><title>Ultra-high frequency spectral characteristics of partial discharge in insulation oil</title><title>2008 International Conference on Condition Monitoring and Diagnosis</title><addtitle>CMD</addtitle><description>We have designed and manufactured four types of typical defects found in power transformers to simulate partial discharge (PD) in oil insulated power transformers. Stable PD signals were generated by applying AC voltages on to the PD cells. We measured spectral response of PD signals from these defects using our Ultra-high frequency (UHF) PD measuring system and apparent discharge using IEC60270 PD detector simultaneously. Partial discharges from the defects in oil generated well detectable UHF signal up to about 2 GHz. UHF PD patterns were recorded and analyzed for each defect types. The phase resolved partial discharge (PRPD) patterns of defect obtained from UHF range were different from each other. The patterns of UHF PD signals were also different from those obtained from that of conventional method. Type of defect could be identified by obtaining PRPD patterns.</description><subject>Frequency measurement</subject><subject>Oil</subject><subject>Oil insulation</subject><subject>Partial Discharge</subject><subject>Partial discharge measurement</subject><subject>Partial discharges</subject><subject>Petroleum</subject><subject>Power transformer insulation</subject><subject>Power transformers</subject><subject>PRPD</subject><subject>Signal generators</subject><subject>UHF</subject><subject>UHF measurements</subject><subject>Virtual manufacturing</subject><isbn>9781424416219</isbn><isbn>1424416213</isbn><isbn>9781424416226</isbn><isbn>1424416221</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2008</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNpVUEtLAzEQjkhBrb0LXvIHtua52TnKqlWoeKnnMhsn3cja1mR76L83Yi8OA8P3YPhmGLuRYi6lgLv29WGuhGjmxjZCaXnGZuAaaZQxslaqPv-HJUzYVbE7EBakvWCznD9FKWO1BnvJVu_DmLDq46bnIdH3gbb-yPOefKEH7ntM6EdKMY_RZ74LfI9pjEX6iPlX3RCP29L5MOAYd1u-i8M1mwQcMs1Oc8pWT4-r9rlavi1e2vtlFUGMlUYjje08BVCSnHOKPAA6C5q6EtnWGrsg0DlL5II2Aj1aIB0EaVUOmLLbv7WRiNb7FL8wHdenv-gf9GRUqw</recordid><startdate>200804</startdate><enddate>200804</enddate><creator>Sun-geun Goo</creator><creator>Hyeongjun Ju</creator><creator>Kijun Park</creator><creator>Kiseon Han</creator><creator>Jinyul Yoon</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>200804</creationdate><title>Ultra-high frequency spectral characteristics of partial discharge in insulation oil</title><author>Sun-geun Goo ; Hyeongjun Ju ; Kijun Park ; Kiseon Han ; Jinyul Yoon</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-3a4145bcef921e7772ec99a7593eb007563abf0a775ee7f340aca59e3f0e32453</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Frequency measurement</topic><topic>Oil</topic><topic>Oil insulation</topic><topic>Partial Discharge</topic><topic>Partial discharge measurement</topic><topic>Partial discharges</topic><topic>Petroleum</topic><topic>Power transformer insulation</topic><topic>Power transformers</topic><topic>PRPD</topic><topic>Signal generators</topic><topic>UHF</topic><topic>UHF measurements</topic><topic>Virtual manufacturing</topic><toplevel>online_resources</toplevel><creatorcontrib>Sun-geun Goo</creatorcontrib><creatorcontrib>Hyeongjun Ju</creatorcontrib><creatorcontrib>Kijun Park</creatorcontrib><creatorcontrib>Kiseon Han</creatorcontrib><creatorcontrib>Jinyul Yoon</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Xplore</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Sun-geun Goo</au><au>Hyeongjun Ju</au><au>Kijun Park</au><au>Kiseon Han</au><au>Jinyul Yoon</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Ultra-high frequency spectral characteristics of partial discharge in insulation oil</atitle><btitle>2008 International Conference on Condition Monitoring and Diagnosis</btitle><stitle>CMD</stitle><date>2008-04</date><risdate>2008</risdate><spage>64</spage><epage>67</epage><pages>64-67</pages><isbn>9781424416219</isbn><isbn>1424416213</isbn><eisbn>9781424416226</eisbn><eisbn>1424416221</eisbn><abstract>We have designed and manufactured four types of typical defects found in power transformers to simulate partial discharge (PD) in oil insulated power transformers. Stable PD signals were generated by applying AC voltages on to the PD cells. We measured spectral response of PD signals from these defects using our Ultra-high frequency (UHF) PD measuring system and apparent discharge using IEC60270 PD detector simultaneously. Partial discharges from the defects in oil generated well detectable UHF signal up to about 2 GHz. UHF PD patterns were recorded and analyzed for each defect types. The phase resolved partial discharge (PRPD) patterns of defect obtained from UHF range were different from each other. The patterns of UHF PD signals were also different from those obtained from that of conventional method. Type of defect could be identified by obtaining PRPD patterns.</abstract><pub>IEEE</pub><doi>10.1109/CMD.2008.4580231</doi><tpages>4</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 9781424416219
ispartof 2008 International Conference on Condition Monitoring and Diagnosis, 2008, p.64-67
issn
language eng
recordid cdi_ieee_primary_4580231
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Frequency measurement
Oil
Oil insulation
Partial Discharge
Partial discharge measurement
Partial discharges
Petroleum
Power transformer insulation
Power transformers
PRPD
Signal generators
UHF
UHF measurements
Virtual manufacturing
title Ultra-high frequency spectral characteristics of partial discharge in insulation oil
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-29T04%3A30%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Ultra-high%20frequency%20spectral%20characteristics%20of%20partial%20discharge%20in%20insulation%20oil&rft.btitle=2008%20International%20Conference%20on%20Condition%20Monitoring%20and%20Diagnosis&rft.au=Sun-geun%20Goo&rft.date=2008-04&rft.spage=64&rft.epage=67&rft.pages=64-67&rft.isbn=9781424416219&rft.isbn_list=1424416213&rft_id=info:doi/10.1109/CMD.2008.4580231&rft_dat=%3Cieee_6IE%3E4580231%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781424416226&rft.eisbn_list=1424416221&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4580231&rfr_iscdi=true