Outline about the EMC properties and throughputs of the PLC systems up to 100 MHz

Advanced communication technologies has allowed the powerline communication (PLC) channel to be a transmission medium that enables the transferring of high-speed digital data over the classical indoor electrical wires. Nowadays, the 200 Mbits/s theoretical rates of the Homeplug AV specification are...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Tlich, M., Razafferson, R., Avril, G., Zeddam, A.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 262
container_issue
container_start_page 259
container_title
container_volume
creator Tlich, M.
Razafferson, R.
Avril, G.
Zeddam, A.
description Advanced communication technologies has allowed the powerline communication (PLC) channel to be a transmission medium that enables the transferring of high-speed digital data over the classical indoor electrical wires. Nowadays, the 200 Mbits/s theoretical rates of the Homeplug AV specification are no still sufficient for transferring Internet, voice, HD videos, and data services simultaneously through the electrical support, especially as real data merely exceed 70 Mbits/s. In this note, a brief Electromagnetic Compatibility analysis and throughput calculation of the PLC systems is carried out. The frequency band up to 30 MHz, characterizing PLC modems, is here pushed up to 100 MHz. The investigation is aimed to increase PLC throughputs by extending the frequency band above 30 MHz.
doi_str_mv 10.1109/ISPLC.2008.4510435
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4510435</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4510435</ieee_id><sourcerecordid>4510435</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-a12c8fbc1edb43589d8ba850731ace00b7dbf6c69cc9caeaccdc37b008e9a02d3</originalsourceid><addsrcrecordid>eNo1kM1OwzAQhI1QJWjJC8DFL5Cy_ovjI4oKrZSqIOBc2c6GBrVNFDuH8vSNoOxlNaNPq5kl5J7BnDEwj6v317KYc4B8LhUDKdQVSYzOmeRSMqMzuCbTf6HYhExHVhswRpobkoTwDeNIJbjkt-RtM8R9c0RqXTtEGndIF-uCdn3bYR8bDNQeq9Hu2-Fr1w0x0Lb-pcYQNJxCxEOgQ0djSxkAXS9_7siktvuAyWXPyOfz4qNYpuXmZVU8lWnDtIqpZdzntfMMKzd2yE2VO5sr0IJZjwBOV67OfGa8N96i9b7yQruxNhoLvBIz8vB3t0HEbdc3B9uftpeXiDP8l1Lh</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Outline about the EMC properties and throughputs of the PLC systems up to 100 MHz</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Tlich, M. ; Razafferson, R. ; Avril, G. ; Zeddam, A.</creator><creatorcontrib>Tlich, M. ; Razafferson, R. ; Avril, G. ; Zeddam, A.</creatorcontrib><description>Advanced communication technologies has allowed the powerline communication (PLC) channel to be a transmission medium that enables the transferring of high-speed digital data over the classical indoor electrical wires. Nowadays, the 200 Mbits/s theoretical rates of the Homeplug AV specification are no still sufficient for transferring Internet, voice, HD videos, and data services simultaneously through the electrical support, especially as real data merely exceed 70 Mbits/s. In this note, a brief Electromagnetic Compatibility analysis and throughput calculation of the PLC systems is carried out. The frequency band up to 30 MHz, characterizing PLC modems, is here pushed up to 100 MHz. The investigation is aimed to increase PLC throughputs by extending the frequency band above 30 MHz.</description><identifier>ISBN: 1424419751</identifier><identifier>ISBN: 9781424419753</identifier><identifier>EISBN: 9781424419760</identifier><identifier>EISBN: 142441976X</identifier><identifier>DOI: 10.1109/ISPLC.2008.4510435</identifier><identifier>LCCN: 2007909949</identifier><language>eng</language><publisher>IEEE</publisher><subject>Communications technology ; Electromagnetic analysis ; Electromagnetic compatibility ; Frequency ; High definition video ; Modems ; Programmable control ; Throughput ; Web and internet services ; Wires</subject><ispartof>2008 IEEE International Symposium on Power Line Communications and Its Applications, 2008, p.259-262</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4510435$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,27902,54895</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4510435$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Tlich, M.</creatorcontrib><creatorcontrib>Razafferson, R.</creatorcontrib><creatorcontrib>Avril, G.</creatorcontrib><creatorcontrib>Zeddam, A.</creatorcontrib><title>Outline about the EMC properties and throughputs of the PLC systems up to 100 MHz</title><title>2008 IEEE International Symposium on Power Line Communications and Its Applications</title><addtitle>ISPLC</addtitle><description>Advanced communication technologies has allowed the powerline communication (PLC) channel to be a transmission medium that enables the transferring of high-speed digital data over the classical indoor electrical wires. Nowadays, the 200 Mbits/s theoretical rates of the Homeplug AV specification are no still sufficient for transferring Internet, voice, HD videos, and data services simultaneously through the electrical support, especially as real data merely exceed 70 Mbits/s. In this note, a brief Electromagnetic Compatibility analysis and throughput calculation of the PLC systems is carried out. The frequency band up to 30 MHz, characterizing PLC modems, is here pushed up to 100 MHz. The investigation is aimed to increase PLC throughputs by extending the frequency band above 30 MHz.</description><subject>Communications technology</subject><subject>Electromagnetic analysis</subject><subject>Electromagnetic compatibility</subject><subject>Frequency</subject><subject>High definition video</subject><subject>Modems</subject><subject>Programmable control</subject><subject>Throughput</subject><subject>Web and internet services</subject><subject>Wires</subject><isbn>1424419751</isbn><isbn>9781424419753</isbn><isbn>9781424419760</isbn><isbn>142441976X</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2008</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo1kM1OwzAQhI1QJWjJC8DFL5Cy_ovjI4oKrZSqIOBc2c6GBrVNFDuH8vSNoOxlNaNPq5kl5J7BnDEwj6v317KYc4B8LhUDKdQVSYzOmeRSMqMzuCbTf6HYhExHVhswRpobkoTwDeNIJbjkt-RtM8R9c0RqXTtEGndIF-uCdn3bYR8bDNQeq9Hu2-Fr1w0x0Lb-pcYQNJxCxEOgQ0djSxkAXS9_7siktvuAyWXPyOfz4qNYpuXmZVU8lWnDtIqpZdzntfMMKzd2yE2VO5sr0IJZjwBOV67OfGa8N96i9b7yQruxNhoLvBIz8vB3t0HEbdc3B9uftpeXiDP8l1Lh</recordid><startdate>200804</startdate><enddate>200804</enddate><creator>Tlich, M.</creator><creator>Razafferson, R.</creator><creator>Avril, G.</creator><creator>Zeddam, A.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>200804</creationdate><title>Outline about the EMC properties and throughputs of the PLC systems up to 100 MHz</title><author>Tlich, M. ; Razafferson, R. ; Avril, G. ; Zeddam, A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-a12c8fbc1edb43589d8ba850731ace00b7dbf6c69cc9caeaccdc37b008e9a02d3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Communications technology</topic><topic>Electromagnetic analysis</topic><topic>Electromagnetic compatibility</topic><topic>Frequency</topic><topic>High definition video</topic><topic>Modems</topic><topic>Programmable control</topic><topic>Throughput</topic><topic>Web and internet services</topic><topic>Wires</topic><toplevel>online_resources</toplevel><creatorcontrib>Tlich, M.</creatorcontrib><creatorcontrib>Razafferson, R.</creatorcontrib><creatorcontrib>Avril, G.</creatorcontrib><creatorcontrib>Zeddam, A.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Tlich, M.</au><au>Razafferson, R.</au><au>Avril, G.</au><au>Zeddam, A.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Outline about the EMC properties and throughputs of the PLC systems up to 100 MHz</atitle><btitle>2008 IEEE International Symposium on Power Line Communications and Its Applications</btitle><stitle>ISPLC</stitle><date>2008-04</date><risdate>2008</risdate><spage>259</spage><epage>262</epage><pages>259-262</pages><isbn>1424419751</isbn><isbn>9781424419753</isbn><eisbn>9781424419760</eisbn><eisbn>142441976X</eisbn><abstract>Advanced communication technologies has allowed the powerline communication (PLC) channel to be a transmission medium that enables the transferring of high-speed digital data over the classical indoor electrical wires. Nowadays, the 200 Mbits/s theoretical rates of the Homeplug AV specification are no still sufficient for transferring Internet, voice, HD videos, and data services simultaneously through the electrical support, especially as real data merely exceed 70 Mbits/s. In this note, a brief Electromagnetic Compatibility analysis and throughput calculation of the PLC systems is carried out. The frequency band up to 30 MHz, characterizing PLC modems, is here pushed up to 100 MHz. The investigation is aimed to increase PLC throughputs by extending the frequency band above 30 MHz.</abstract><pub>IEEE</pub><doi>10.1109/ISPLC.2008.4510435</doi><tpages>4</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 1424419751
ispartof 2008 IEEE International Symposium on Power Line Communications and Its Applications, 2008, p.259-262
issn
language eng
recordid cdi_ieee_primary_4510435
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Communications technology
Electromagnetic analysis
Electromagnetic compatibility
Frequency
High definition video
Modems
Programmable control
Throughput
Web and internet services
Wires
title Outline about the EMC properties and throughputs of the PLC systems up to 100 MHz
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T09%3A38%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Outline%20about%20the%20EMC%20properties%20and%20throughputs%20of%20the%20PLC%20systems%20up%20to%20100%20MHz&rft.btitle=2008%20IEEE%20International%20Symposium%20on%20Power%20Line%20Communications%20and%20Its%20Applications&rft.au=Tlich,%20M.&rft.date=2008-04&rft.spage=259&rft.epage=262&rft.pages=259-262&rft.isbn=1424419751&rft.isbn_list=9781424419753&rft_id=info:doi/10.1109/ISPLC.2008.4510435&rft_dat=%3Cieee_6IE%3E4510435%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781424419760&rft.eisbn_list=142441976X&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4510435&rfr_iscdi=true